Campbell Hausfeld EX8000 Series Operating Instructions Manual

Summary of EX8000 Series

  • Page 1

    Portable air compressors please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and...

  • Page 3

    Gauge of cord 14 10 10 8 6 6 4 4 2 extension cords for 120v/15 amp unit length of cord (ft) 25 50 100 150 200 250 300 400 500 ex8000, wl5000 series contractor models 3 installation (cont.) appropriate grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in acco...

  • Page 4: Notas

    Almacenamiento 1. Mientras no lo esté usando debe almacenar el compresor y las mangueras en un sitio seco y frío. 2. Debe drenar el tanque. 3. Debe desconectar las mangueras y colgarlas con los extremos hacia abajo para que se drenen. Ex8000, wl5000 serie de modelos para contratistas 17 sp mantenimi...

  • Page 5

    Troubleshooting chart symptom possible cause(s) corrective action 1. Loss of power or overheating 2. No electrical power 3. Blown fuse 4. Breaker open 5. Thermal overload open 6. Pressure switch bad 1. Low voltage 2. Wrong gauge wire or length of extension cord 3. Shorted or open motor winding 4. De...

  • Page 6

    Calibre del cordón 14 10 10 8 6 6 4 4 2 cordones de extensión para los modelos de 120v/15 amp longitud del cordón (m) 7,62 15,24 30,48 45,72 60,96 76,2 91,44 121,92 152,4 ex8000, wl5000 serie de modelos para contratistas 15 sp instalación (continuación) si no conecta los cables adecuadamente podría ...