Campbell Hausfeld FP2400 Operating Instructions Manual

Manual is about: Campbell Cordless Air Compressor User Manual Model FP2400

Summary of FP2400

  • Page 1

    Q ua lit y a ssurance p rog ra m need assistance? Call us first! 1-800-543-8622 note: unit will not run when charging. Do not operate unit if damaged during shipping, handling or use. Damage may result in bursting and cause injury or property damage. General safety since the air compressor and other...

  • Page 2

    31 20. Never leave unit unattended while in use. 21. Protect the unit from rain, snow or other sources of moisture. 22. Turn off power switch when not in use. 23. Always replace the fuse with the same amperage rating (20 amp). Never use a fuse with a higher amperage rating. The cordless compressor b...

  • Page 3

    30 sp battery for 7 to 9 hours. If the unit is used too long after the yellow light comes on, recharging time could take up to 20 hours and the battery life may be shortened. 4. Do not operate the unit while recharging with the 120-volt ac adapter. Unit will not run while recharging. Battery indicat...

  • Page 4

    29 sp maintenance disconnect power source and then release all pressure from the system before attempting to install, service, relocate or perform any maintenance. The compressor should be checked often for any visible problems and the following maintenance procedures should be performed each time t...

  • Page 5

    28 sp 5 model fp2400 www.Chpower.Com maintenance ( cont.) storage 1. When not in use, store hose and compressor in a cool dry place. 2. Disconnect hose and hang open ends down, to allow any moisture to drain. Technical service for information regarding the opera- tion or repair of this product, plea...

  • Page 6

    27 sp 6 cordless air compressor www.Chpower.Com troubleshooting chart symptom possible cause(s) corrective action 1. No electrical power to charger 2. Blown fuse 3. Thermal overload open 4. Charger plugged in incorrect size fuse, circuit overloaded 1. Compressor is being overworked 2. Lack of proper...

  • Page 7

    7 model fp2400 1. Air consumption higher than compressor output 2. Air leak 3. Internal leak 4. Defective pump 1. Defective pressure switch. 2. Other electrical problem 1. No 120 volt ac supply to charger 2. Charger not plugged in 3. Defective charger 4. Fuse blown or not installed 5. Power switch o...

  • Page 8

    25 sp 8 cordless air compressor www.Chpower.Com modelo fp2400 montaje en la pared (cont.) que se muestra en la figura 2, y ajustarse en forma segura al montante o al hormigón con tornillos de montaje para hormigón. Mantenimiento desconecte la fuente de energía y luego libere toda la presión del sist...

  • Page 9

    24 sp 9 model fp2400 1 handle kit fp240031av 1 2 storage cover fp240032av 1 3 shroud upper fp240033av 1 4 on/off switch 1 5 ac adapter plug 1 6 fuse (20a) fp240023av 1 7 fuse holder 1 8 battery fp240007av 1 9 pump/motor assembly fp240008av 1 10 electrical board fp240009av 1 11 air receiver fp240010a...

  • Page 10

    23 sp 10 limited warranty 1. Duration: one year from the date of purchase by the original purchaser: one year. 2. Who gives this warranty (warrantor): campbell hausfeld / scott fetzer company, 100 production drive, harrison, ohio, 45030, telephone: (800) 543-6400 3. Who receives this warranty (purch...

  • Page 11

    22 sp q ua lit y a ssurance p rog ra m need assistance? Call us first! 1-800-543-8622 note : l'appareil ne fonctionnera pas en chargeant. Ne faites pas fonctionner l’appareil s’il a été endommagé durant le transport, sa manipulation ou son utilisation. Les dommages peuvent provoquer un éclatement et...

  • Page 12

    12 fr 19. Ne jamais faire fonctionner le compresseur près d'incendies, de gaz ou de liquides inflammables. 20. Ne jamais laisser l'appareil sans superviseur pendant son fonctionnement. 21. Protéger l'appareil de la pluie, de la neige ou d'autres sources d'humidité. 22. Couper le courant lorsque l'ap...

  • Page 13

    20 fr 13 fr 120 volt c.A. De charge pour recharger la pile à l'aide de l'adaptateur de c.A. 120 volts, suivre les procédures suivantes : 1. Pousser le commutateur de courant à la position d'arrêt (off) et insérez l'adaptateur de c.A. De 120 volts de charge dans une douille d'entrée de charge c.A. Qu...

  • Page 14

    19 sp 14 fr d'élimination des piles. Régulateur 1.Ce régulateur contrôle la pression d'air au boyau et aux accessoires. 2. Tourner le bouton dans le sens horaire augmente la pression à la sortie. 3. Tourner le bouton dans le sens antihoraire réduit la pression à la sortie. Montage au mur ce compress...

  • Page 15

    18 fr 15 fr modéle fp2400 entretien débrancher la source de courant et ensuite dégager toute la pression du système avant d'essayer d'installer, de réparer, de replacer ou d'effectuer tout entretien. Le compresseur doit être vérifié pour tout signe visible de problème et les procédures suivantes d'e...

  • Page 16

    17 fr 16 fr compresseur d'air sans fil tableau de dépannage modéle fp2400 tableau de dépannage (suite) symptôme causes possibles mesure correctiven le compresseur ne fonctionne pas fusibles grillés / disjoncteur déclenché protecteur de surcharge thermique coupe à répétition coups, bruits, vibrations...