Before using your air conditioner, please read this manual carefully and keep it for future reference. Window/wall type room air conditioner - before using your air conditioner, please read this manual carefully and keep it for future reference. Window/wall type room air conditioner - before using y...
Sociable remark the following contents apply only the countries of europe. Disposal: do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposa...
Contents 1 . S a f e t y p r ec a u t i o n s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. Unit parts identification ................. .............................................4 3. Air conditioner features....................................
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. Safety precautions this symbol indicates the possi...
! Caution when the air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury. Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury. Operation with windows opened may cause wetting of indoor and soaking of household fur...
Preparing for operation usage cleaning and maintenance service operating temperature 1. Contact an installation specialist for installation. 2. Plug in the power plug properly. 3. Do not use a damaged or non-standard power cord. 4. Do not share the same outlet with other appliances. 5. Do not use an...
1. Front panel 2. Air filter 3. Frame 4. Cabinet 5. Air inlet grille (outdoor side) 6. Air outlet grille 7. Operation knob 8. Power supply cord unit parts identification 1. Power cord conductors are distinguished according to color as follows (see fig.1) 2. For your safety and protection, this unit ...
Note : the outline of the operation panel is based on typical model, the function is the same with your air conditioner while some difference may exist in appearance. Selector power indicator(some models without): this indicator light remains on when the unit is on and goes off when the selector is ...
Thermostat thermostat cooler to set the desired room temperature, rotate the thermostat switch to the desired setting. After the set temperature is achieved the thermostat will automatically start and stop the compressor in order to maintain the desired set temperature. Rotate the thermostat selecto...
Vertical air flow adjustment (manually) to adjust vertical air flow direction, adjust any one of the horizontal louver blades. When turning up or down the horizontal louver blades, always keep horizontality the top or bottom blades. This can effectively prevent water drops condensed on the front pan...
Hold the slot under the front panel, then uplift it onwards, and remove the front panel. Pinch the handle under the air filter and make the air filter arched, remove it from the underside to upside. Wash the filter using liquid dishwashing detergent and warm water. Rinse filter thoroughly. Gently sh...
O 45 scrape 5- 10 m m less than c more than d more thana more than b less than more thana wall thickness is less than c if the wall thickness is more than scrape the wall as shown above. Make rear side lower so that water will drain out smoothly. C c size(mm) a b c d 400 500 210 60 installation(cont...
Installation steps step 1. Remove the front panel and the air filter 1. Hold the slot under the front panel, then uplift it outwards, and remove the front panel (see fig.1). 2. Pinch the handle under the air filter and make the air filter arched, remove it from the slot from underside to upside (see...
1. Install the frame. (see fig.9) 2. Fix the screws on the frame. (see fig.3) 1. Install the air filter into the frame's slot from upside to underside. (see fig.2) 2. Hang the front panel on the frame's buckle, then press the front panel into the frame's slot until hear a click. (see fig.10) step 5....
Solution problem air conditioner turns on and off rapidly noise when unit is cooling water dripping inside when unit is cooling. Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation instructions - check with installer. Dirty air filter- a...
13 minimum norminal cross-sectional area of conductors: rated current of appliance (a) nominal cross-sectional area 2 (mm ) 0.75 1 1.5 2.5 suggest minimum wire size ( awg: ) : american wire gage appliance amps awg wire size 10 13 18 25 18 16 14 12 30 10
The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details..