    165 him series softener operation manual note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) nsf certified lubricant to all seals. Rev 8, december 28 2011.

  • Page 2: Table Of Contents

    2 table of contents water softener gallon setting chart ..................................................................................................................... 3 specifications ................................................................................................................

  • Page 3

    3 water softener gallon setting chart water softener gallon setting chart instructions: first select the chart for your model of water softener, then simply line up the number of people living in the home with the hardness of the water and select the appropriate gallon setting for your model. At 15l...

  • Page 4

    4 specifications this valve is controlled with simple, user-friendly electronics displayed on a lcd screen. The main page displays the current time and the remaining gallons in meter mode or the remaining days in calendar clock mode. Figure 2. Valve display figure 3. Valve display system initializat...

  • Page 5

    5 programming 1. Press ‘ ’ to enter programming. If the system has been inactive, you may have to hold and press ‘ ’ until you hear a beep to unlock the display screen. Press ‘ ’ or ‘ ’ to select which setting to modify. 2. To change setting, press ‘ ’. When the display flashes, the value may be cha...

  • Page 6

    6 program options depending on the current option settings, some parameters cannot be viewed or set. Program mode parameter options description 1 regional metric this option controls whether cubic meters or us gallons is used for the volume display and the format of the day, year, and month. Us 2 re...

  • Page 7

    7 general valve installation water pressure minimum 25 psi electrical supply uninterrupted 115v ac existing plumbing free of any deposits or build-ups inside pipes. Softener location locate close to drain and connect according to plumbing codes bypass valves always provide for bypass valve if unit i...

  • Page 8

    8 7. Add water until there is approximately 1" (25 mm) of water above the grid plate. If the tank does not have a grid, add water until it is above the air check in the brine tank. Do not add salt to the brine tank at this time. 8. Place the unit in the bypass position. 9. Slowly turn on the main wa...

  • Page 9

    9 system configuration @ 15 lbs/cu ft (factory setting) @ 10 lbs/cu ft @ 6 lbs/cu ft @ 3 lbs/cu ft backwash brine/rinse rinse @ 15 lbs/cu ft (factory setting) @ 10 lbs/cu ft @ 6 lbs/cu ft @ 3 lbs/cu ft 0.75 22,500 19,875 16,500 10,500 10.0 60.0 10.0 6.0 4.0 2.0 1.1 1.00 30,000 26,500 22,000 14,000 1...

  • Page 10

    10 figure 10. Bypass installation view manual bypass in the case of emergency, such as an overflowing brine tank, you can isolate your water softener from the water supply using the bypass valve located at the back of the control. In normal operation the bypass is open with the on/off knobs in line ...

  • Page 11

    11 figure 11 injector assembly cleaning the injector assembly sediment, salt and silt will restrict or clog the injector. A clean water supply and pure salt will prevent this from happening. The injector assembly is located on the right side of the control valve. This assembly is easy to clean. Shut...

  • Page 12

    12 power head exploded view see parts listing on next page (13).

  • Page 13

    13 power head parts list item no. Part no. Part description quantity b01 5056136 screw-st3.5×13(hexagon with washer) 4 b02 5056014 bnt65 back cover 1 b03 5010045 piston stem holder 1 a26 13000426 screw-st2.9×13(large wafer) 1 b04 5056139 washer-3x13 1 b05 5056005 main gear 1 b06 5056083 screw-m4x14 ...

  • Page 14

    14 control valve exploded view see parts listing on next page (15).

  • Page 15

    15 control valve parts list item n o. P art n o. P art d iscription q uantity a 01 05056087 s crew -m 5×12(h exagon) 3 a 02 05056088 s crew -m 5×16(h exagon w ith w asher) 2 a 03 05056047 e nd p lug r etainer 1 a 04 05010081 b nt65 p iston r od 1 a 05 05056097 p iston p in 1 a 06 05056023 e nd p lug...

  • Page 16

    16 trouble shooting issue possible cause possible solution 1. No power supply. Check electrical service, fuse, etc. 2. Defective circuit board. Replace faulty parts. 3. Power failure. Reset time of day. 1. By-pass valve open. Close by-pass valve. 2. Out of salt. Add salt to tank. 3. Plugged injector...

  • Page 17

    17.

  • Page 18: Manufacturers

    18 manufacturers warranty canature north america inc. Warrants that your new water conditioner is built of quality material and workmanship. When properly installed and maintained, it will give years of trouble free service. Five year complete parts guarantee: canature north america inc. Will replac...