Canoga Perkins EdgeAccess 9135 SNMP User Manual

Manual is about: Universal Chassis System, Managed 10/100/1000 Ethernet Switch

Summary of EdgeAccess 9135 SNMP

  • Page 1

    Model 9135 snmp managed 10/100/1000 ethernet switch user manual.

  • Page 3: Caution!

    Edgeaccess universal chassis system model 9135 10/100/1000 i caution! This product may contain a laser diode operating at a wavelength of 1300nm - 1600nm. Use of optical instruments (e.G., collimating optics) with this product may increase eye hazard. Use of controls or adjustments, or performing pr...

  • Page 4: Notice

    Edgeaccess universal chassis system model 9135 10/100/1000 ii notice canoga perkins has prepared this users manual for use by customers and canoga perkins personnel as a guide for the proper installation, operation and/or maintenance of canoga perkins equipment. The drawings, specifications and info...

  • Page 5: Table of Contents

    Edgeaccess universal chassis system model 9135 10/100/1000 iii table of contents chapter 1 overview ................................................................................................ 1-1 1.1 data switch features .............................................................................

  • Page 6: List Of Figures

    Edgeaccess universal chassis system model 9135 10/100/1000 iv appendix a warranty............................................................................................A-1 appendix b acronyms............................................................................................ B-1 list of...

  • Page 7: List Of Tables

    Edgeaccess universal chassis system model 9135 10/100/1000 v list of tables table 1. Sw1 settings, utp copper interface.................................................................................. 2-1 table 2. Sw1 settings, 100 base modules, fiber optic interface ..................................

  • Page 8

    Edgeaccess universal chassis system model 9135 10/100/1000 vi.

  • Page 9: Chapter 1

    Edgeaccess universal chassis system model 9135 10/100/1000 1-1 chapter 1 overview the canoga perkins edgeaccess 9135 is an snmp managed, two-port ethernet switch that provides managers and network analysts with a modular-managed 10/100 or 1000 mbps lan platform. See figure 1. The 9135 switch support...

  • Page 10

    Edgeaccess universal chassis system model 9135 10/100/1000 1-2 1.2 hardware management features the 9135 includes these hardware features for switch management: • alarm relay contacts that can transmit these fault conditions for each port. • loss of link integrity • remote fault • power failure • sn...

  • Page 11: Chapter 2

    Edgeaccess universal chassis system model 9135 10/100/1000 2-1 chapter 2 setup and installation this section describes how to install the 9135 and the interface modules. Caution equipment intended only for installation in a restricted access location accessible only to electrically skilled persons a...

  • Page 12

    Edgeaccess universal chassis system model 9135 10/100/1000 2-2 3. On the 100 base modules, fiber optic interface (9100-44x, -54x, -64x, or -74x), set sw1 for your system; see figure 3 and table 2. Sw1 figure 3. Sw1 on 100 base modules, fiber optic interface table 2. Sw1 settings, 100 base modules, f...

  • Page 13

    Edgeaccess universal chassis system model 9135 10/100/1000 2-3 table 3. Sw1 settings, 1000 base modules, fiber optic interface switch name on off 1-1 llf enable llf disable llf 1-2 lle enable lle disable lle 5. Mount the 9135 in a rack or as a standalone unit. • use the standard rackmount kit with b...

  • Page 14

    Edgeaccess universal chassis system model 9135 10/100/1000 2-4 dirty optical connectors are a common cause of link loss or attenuation problems, especially for single mode fiber (smf). Clean the connectors before plugging in a cable and whenever there is a significant or unexplained light loss. To p...

  • Page 15

    Edgeaccess universal chassis system model 9135 10/100/1000 2-5 table 5. 9135 interface module leds led status indicates tx (transmit) off no transmit activity green current transmit activity red transmitter disabled due to llf or lle lnk (link) off no optical link green optical link established col ...

  • Page 16

    Edgeaccess universal chassis system model 9135 10/100/1000 2-6.

  • Page 17: Chapter 3

    Edgeaccess universal chassis system model 9135 10/100/1000 3-1 chapter 3 management configure the 9135 through the management software. For your first session, you must use hyperterminal; you can set up telnet access through the host table/snmp settings menu. 3.1 set up the serial port the first tim...

  • Page 18

    Edgeaccess universal chassis system model 9135 10/100/1000 3-2 messages and urgent status screen navigation instructions change options status reports model number chassis and slot numbers figure 5. Typical 9135 screen not all screens and menus provide options that you can change. Some menu items re...

  • Page 19

    Edgeaccess universal chassis system model 9135 10/100/1000 3-3 main menu 1. System 2. Switch configuration 3. Port information 4. Reports 5. Diagnostics 6. Restore defaults 7. Restart 8. Logout figure 7. Main menu the main menu provides access to all functions for the 9135: setup, diagnostics, and r...

  • Page 20

    Edgeaccess universal chassis system model 9135 10/100/1000 3-4 table 7. System menu options menu item description 1. Ip settings set the ip parameters 2. Host table / snmp settings set up the host table and snmp access 3. Slip port settings set up for serial line interface port (slip) access 4. Pass...

  • Page 21

    Edgeaccess universal chassis system model 9135 10/100/1000 3-5 table 8. Ip settings menu options menu item description 1. Local ip address set the network address of the 9135. The first octet of the ip address defines the class, or how the ip address is split between the network id and the host id. ...

  • Page 22

    Edgeaccess universal chassis system model 9135 10/100/1000 3-6 3.4.2 host table / snmp settings use the host table and snmp settings menu to set access levels for hosts and destinations for traps. You can set the access and trap community for various ip addresses. By default, a trap community is "pu...

  • Page 23

    Edgeaccess universal chassis system model 9135 10/100/1000 3-7 host table/snmp settings snmp access trap trap ip address access level community port 1. 172.16.142.1 snmp only read/write/trap public 162 2. 172.16.142.4 snmp only read/write/trap public 163 3. 172.16.142.3 snmp only read/write/trap pub...

  • Page 24

    Edgeaccess universal chassis system model 9135 10/100/1000 3-8 slip port settings terminal type: : vt100 1. Interface 2. Init modem at startup 3. Modem init string 4. Password enable 5. Password 6. Slip ip address 7. Slip subnet mask 8. Slip port setup 9. Main menu figure 11. Slip port settings menu...

  • Page 25

    Edgeaccess universal chassis system model 9135 10/100/1000 3-9 3. At the prompt, type the new password, up to 18 characters, then type it again to confirm it and save it. Note: all letters, numbers, and characters are legal; the password is case sensitive. Passwords you are logged in as : 1. Change ...

  • Page 26

    Edgeaccess universal chassis system model 9135 10/100/1000 3-10 menu and selection minimum access menu and selection minimum access host table / snmp settings menu port n details menu read community supervisor clear counters user write community supervisor traps log menu send alert traps supervisor ...

  • Page 27

    Edgeaccess universal chassis system model 9135 10/100/1000 3-11 a c e b d 1 2 3 4 5 6 a small test network a c e b d 1 2 3 4 5 6 spanning tree from source (c) figure 14. Typical spanning tree application. Note: for details on the spanning tree algorithm, see the ieee 802.1 specifications. The spanni...

  • Page 28

    Edgeaccess universal chassis system model 9135 10/100/1000 3-12 global spanning tree parameters 1. Enable spanning tree : 2. Priority : 3. Hello time (sec) : 4. Forward delay (sec) : 5. Max age (sec) : 6. Main menu figure 16. Global spanning tree parameters menu table 13. Global spanning tree parame...

  • Page 29

    Edgeaccess universal chassis system model 9135 10/100/1000 3-13 global spanning tree parameters state : forwarding designated root : 00 00 00 00 00 00 00 00 designated cost : 0 designated bridge : 00 00 00 00 00 00 00 00 1. Change port : 1 2. Priority : 128 3. Path cost : 10 4. Main menu figure 17. ...

  • Page 30

    Edgeaccess universal chassis system model 9135 10/100/1000 3-14 3.5.3 spanning tree report the spanning tree report screen shows the current conditions for the bridge network. See figure 18 and table 16. To access the spanning tree report, see figure and follow these steps: 1. From the main menu, ty...

  • Page 31

    Edgeaccess universal chassis system model 9135 10/100/1000 3-15 3.6 port information the various port information and statistics screens shows status for the ports on the 9135. • ports information follows the front panel leds; see figure 19. • port n statistics shows standard information about the d...

  • Page 32

    Edgeaccess universal chassis system model 9135 10/100/1000 3-16 port 1 information link : yes llf hw switch : disabled frames received : 282356856 aut hw switch : disabled frames sent : 4472214 fdx hw switch : enabled data rate : 100 mpbs 100 hw switch : enabled duplex : full duplex llf status : no ...

  • Page 33

    Edgeaccess universal chassis system model 9135 10/100/1000 3-17 3.7 reports the reports menu provides access to a brief description of the 9135, the traps log, and the fdb log. See figure 23. Reports 1. Description 2. Traps log 3. Fdb log 4. Main menu figure 23. Reports menu 3.7.1 description report...

  • Page 34

    Edgeaccess universal chassis system model 9135 10/100/1000 3-18 traps log count time 0 days 00:11:07 trap type 1 0 days 00:00:00 cold start () 2 0 days 00:00:01 link up (1) of: 2 1. View previous page 2. View next page 3. Clear the log 4. Main menu figure 25. Traps log screen all users and managers ...

  • Page 35

    Edgeaccess universal chassis system model 9135 10/100/1000 3-19 fdb log count mac port status 109 00 c0 ee d0 90 5b 1 learned 110 00 d0 b7 47 bd 58 1 learned 111 00 d0 b7 83 34 9d 1 learned 112 00 d0 b7 83 45 cb 1 learned 113 00 e0 63 75 3d 34 1 learned 114 00 e0 db 02 bd 4a 1 learned 115 08 00 09 d...

  • Page 36

    Edgeaccess universal chassis system model 9135 10/100/1000 3-20 ping 1. Ping address 2. Ping count 3. Start pinging 4. Main menu figure 28. Ping menu 3.9 restore defaults use the restore defaults option to restore all configurable settings to factory defaults except this network information: • ip ad...

  • Page 38

    Edgeaccess universal chassis system model 9135 10/100/1000 3-22 7. Start the download. The process sends the upgrade directly to the inactive flash location. 8. When the tftp client indicates the transfer is complete, close the tftp program. 9. To activate the new software revision, reset the 9135, ...

  • Page 39

    Edgeaccess universal chassis system model 9135 10/100/1000 3-23 13. When the transfer is complete, a successful message appears. At the prompt, enter quit to close the ftp connection. 14. To activate the new software revision, reset the 9135, then return to the description screen to verify that the ...

  • Page 40

    Edgeaccess universal chassis system model 9135 10/100/1000 3-24.

  • Page 41: Chapter 4

    Edgeaccess universal chassis system model 9135 10/100/1000 4-1 chapter 4 slip connection you can connect a dial-up modem to the dce port on the snmp management module in order to manage the 9135 through snmp. 4.1 configuring the 9135 for slip connect a dce to dte serial modem cable between the 9135 ...

  • Page 42

    Edgeaccess universal chassis system model 9135 10/100/1000 4-2 6. On the basic tab, enter a name and the phone number for the 9135, then from the dial using drop- down, select the modem. 7. On the server tab, from the dial-up server type drop down, select slip: internet, then check tcp/ip and click ...

  • Page 43: Chapter 5

    Edgeaccess universal chassis system model 9135 10/100/1000 5-1 chapter 5 specifications 5.1 switch specifications switching characteristics bridging: per ieee 802.1d spanning tree address table: maximum 1000 mac addresses entry forwarding rate: 148,800 packets-per-second maximum per port buffer memo...

  • Page 44

    Edgeaccess universal chassis system model 9135 10/100/1000 5-2 5.2 9135 ports and pinouts table 17. Terminal port, female de-9 pin signal 1, 4, 8, 9 not used 2 rxd in 3 txd out 5 common 7 ground table 18. Slip port, male de-9 pin signal 1 dcd in 2 rxd in 3 txd out 4 dtr out 5 common 6 dsr in 7 rts o...

  • Page 45

    Edgeaccess universal chassis system model 9135 10/100/1000 5-3 5.3 regulatory compliance and referenced documents complies with these regulations: • etl, cetl (can/csa-c22.2 no.60950/ul 60950) • en 60950, iec 60950 • cdrh cfr21/en60825-1 • fcc part 15b, class a, ic cs-003, c-tick (as/nzs 3548) • en ...

  • Page 46

    Edgeaccess universal chassis system model 9135 10/100/1000 5-4 100base fx fiber optic field-interchangeable interfaces 9100-441 100base fx 1310 nm mm led with st connectors, 11 db w/ 62.5/125 fiber 9100-442 100base fx 1310 nm mm led with duplex sc connectors, 11 db w/ 62.5/125 fiber 9100-641 100base...

  • Page 47

    Edgeaccess universal chassis system model 9135 10/100/1000 5-5 10 base fl sm 20 db emitter type: laser diode wavelength: 1310 nm nominal receive sensitivity: -34 dbm minimum transmit launch power: -6 dbm maximum -15 dbm minimum overdrive: -10 dbm loss budget: 20 db minimum optical connector: st or f...

  • Page 48

    Edgeaccess universal chassis system model 9135 10/100/1000 5-6 100 base fx sm 10 db emitter type: laser diode wavelength: 1310 nm nominal receive sensitivity: -31 dbm minimum transmit launch power: -14 dbm maximum -20 dbm minimum overdrive: -8.0 dbm loss budget: 10 db minimum optical connector: dupl...

  • Page 49

    Edgeaccess universal chassis system model 9135 10/100/1000 5-7 gigabit single mode (sm) 1310 nm lx emitter type: laser diode wavelength: 1310 nm nominal receive sensitivity: -18 dbm minimum transmit launch power: -3.0 dbm maximum -11.0 dbm minimum overdrive: -3.0 dbm maximum loss budget: 7.0 db mini...

  • Page 50

    Edgeaccess universal chassis system model 9135 10/100/1000 5-8.

  • Page 51: Appendix A

    Edgeaccess universal chassis system model 9135 10/100/1000 a-1 appendix a warranty limited lifetime warranty effective july 1, 2005 and after, canoga perkins warrants that, at the time of sale, and, for its lifetime, with certain exceptions noted below, every canoga perkins' labeled product purchase...

  • Page 52

    Edgeaccess universal chassis system model 9135 10/100/1000 a-2 limitations canoga perkins may at its sole discretion modify its limited warranty at any time and from time to time. Other than those expressly stated herein, there are no other warranties of any kind, expressed or implied, and specifica...

  • Page 53: Appendix B

    Edgeaccess universal chassis system model 9135 10/100/1000 b-1 appendix b acronyms bootp boot protocol (a tcp/ip protocol) bpdu bridge protocol data unit cts clear to send dce data communications equipment dsr data signal ready dte data terminal equipment dtr data terminal ready fdx full-duplex lle ...

  • Page 54

    Canoga perkins corporation 20600 prairie street chatsworth, california 91311-6008 usa phone: (818) 718-6300 fax: (818) 718-6312 web site: www.Canoga.Com email: fiber@canoga.Com.