Canoga Perkins L357 User Manual

Manual is about: EdgeAccess Universal Chassis System, Gigabit Ethernet Service Unit

Summary of L357

  • Page 1

    L357 gigabit ethernet service unit user manual.

  • Page 3: Caution!

    Edgeaccess universal chassis system l357 gigabit ethernet service unit i caution! This product may contain a laser diode emitter operating at a wavelength of 1300 nm - 1600 nm. Use of optical instruments (for example: collimating optics) with this product may increase eye hazard. Use of controls or ...

  • Page 4: Notice

    Edgeaccess universal chassis system l357 gigabit ethernet service unit ii notice canoga perkins has prepared this users manual for use by customers and canoga perkins personnel as a guide for the proper installation, operation and/or maintenance of canoga perkins equipment. The drawings, specificati...

  • Page 5: Table of Contents

    Edgeaccess universal chassis system l357 gigabit ethernet service unit iii table of contents chapter 1 overview ................................................................................................ 1-1 1.1 l357 series ..........................................................................

  • Page 6

    Edgeaccess universal chassis system l357 gigabit ethernet service unit iv 4.12 software upgrade.................................................................................................................4-24 4.13 change password .....................................................................

  • Page 7: List Of Figures

    Edgeaccess universal chassis system l357 gigabit ethernet service unit v list of figures figure 1. The l357 ............................................................................................................................ 1-1 figure 2. Switch 1 through 8 locations ...........................

  • Page 8: List Of Tables

    Edgeaccess universal chassis system l357 gigabit ethernet service unit vi list of tables table 1. Switch 1 and 2 utp speed settings.....................................................................................2-2 table 2. Switch 3 through 8 functions .............................................

  • Page 9: Chapter 1

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 1-1 chapter 1 overview the edge access l357 series 10/100/1000 ethernet service unit (esu) converts and extends ethernet media between local area networks (lans) located up to 120 km apart. In addition, the l357 offers quality of...

  • Page 10

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 1-2 1.2 l357 hosts the l357 can be used in a variety of chassis. • to use the ucs 1000 chassis, insert a model 1230 bus access module (bam) that holds up to two l357s per bam. • to use the ucs 1001 chassis, insert up to two model...

  • Page 11: Chapter 2

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 2-1 chapter 2 set-up and installation this section describes how to set up and install the l357. 2.1 set up and install the l357 before setting up the l357, make sure the chassis is installed and its users manual is available for...

  • Page 12

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 2-2 table 1. Switch 1 and 2 utp speed settings switch 1 switch 2 speed off off 1000 mbps off on 100 mbps on off 10 mbps on on autonegotiate table 2. Switch 3 through 8 functions switch function on off 3 full duplex on utp user po...

  • Page 13

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 2-3 2.2 install the cables the l357 uses both electrical and fiber optic cables. Electrical utp cables connect to the user port. Fiber optic cables connect to the extension port. Dirty optical connectors are a common source of li...

  • Page 14

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 2-4.

  • Page 15: Chapter 3

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 3-1 chapter 3 user operation this chapter describes the hardware features and functions of the l357. 3.1 l357 functions and power up each l357 requires a host for power. During the initial power-up sequence, all leds light amber....

  • Page 16

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 3-2 led status description tx (user port) off no transmission activity green transmission activity amber port in standby mode or system self-test red transmission disabled due to llf or port disabled off 10 mbps data rate spd amb...

  • Page 17

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 3-3 3.3 alarms the l357 can generate major and minor alarms. • in the ucs 1000 and 1002, these alarms are forwarded over the backplane to the cim and appear on the major (maj) and minor (min) cim leds and then are forwarded to th...

  • Page 18

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 3-4 3.3.2 link loss echo caution: to avoid a lockup condition, do not set lle at both the local and remote ends of the link. Link loss echo (lle) propagates a link loss to the device connected to an optical extension or user port...

  • Page 19

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 3-5 • local-remote mode loops the optical data that the remote l357 receives on the extension port rx through the user phy to the extension port tx. The data is not sent out the remote user port tx and incoming data on the remote...

  • Page 20

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 3-6.

  • Page 21: Chapter 4

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-1 chapter 4 management - vt-100 if the l357 is installed in a bam, the system includes a dmm and a cim, or the l357 is in a model 1020 enclosure, you can manage the system through vt100 terminal emulation, which is accessible b...

  • Page 22

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-2 4.3 management user interface the management user interface for the l357 provides screens for setup, monitoring, and diagnostics. You can access the screens directly by connecting to the serial port of the bam, the model 1020...

  • Page 23

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-3 4.3.2 user interface organization the user interface consists of selectable, nested screens, available in this order: main menu 1. System configuration 1. Hardware configuration 2. Functional configuration 3. Trap configurati...

  • Page 24

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-4 4.3.4 dmm main menu if you are using a dmm, after you log in, the main menu for the dmm appears. This is the main management screen for the dmm. For details on all menu options, see the model 1500 domain management module use...

  • Page 25

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-5 4.5 system configuration menu the system configuration menu provides access to most configuration options for the l357. To access the system configuration menu, see figure 11 and table 4 and follow these steps: 1. From the ma...

  • Page 26

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-6 4.5.1 hardware configuration screen the hardware configuration report shows various configuration settings, including the module type, with model and revision numbers, and the power supply status. In addition, it shows inform...

  • Page 27

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-7 4.5.2 functional configuration screen the functional configuration report and menu provides information about the hardware, with options to set software control. You can only view the options for the remote module, but you ca...

  • Page 28

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-8 table 5. Functional configuration option definitions menu item description 1) configuration option control software: set the l357 to follow settings in software and ignore hardware switches hardware: set the l357 to follow ha...

  • Page 29

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-9 remote vlan configuration user port ext port 1) drop untagged packet? No no 2) drop packets with vlan tag not matching vlan tag a? No no 3) remove outermost vlan tag? No no 4) add vlan tag b to untagged packets only? No no 5)...

  • Page 30

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-10 4.5.3 trap configuration traps are messages to alert network management about conditions. The dmm logs the traps and the dmm or model 1020 transmits them by snmp to the network manager. At the trap configuration screen, enab...

  • Page 31

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-11 alarm output configuration 1) factory defaults 2) link down alarm off 3) rmtf alarm off 4) llf alarm off 5) configuration alarm off 6) power/fan/temperature alarm minor 7) sbmc loss alarm off 8) power-on self test alarm off ...

  • Page 32

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-12 ip/snmp agent configuration local remote mac address 00 40 2a 00 87 e3 00 40 2a 00 53 e7 management port up up 1) ethernet ip address 172.016.148.030 172.16.143.10 subnet mask 255.255.000.000 255.255.0.0 default gateway 000....

  • Page 33

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-13 the snmp agent allows access to up to 24 host ip addresses listed in the host table. Set up the host information for the l357 on the host table screen. See figure 23. To access the host table, follow these steps: 1. From the...

  • Page 34

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-14 4.5.6 security configuration the security configuration menu provides options to set values for general parameters for passwords, lockout, and logout. To access the security configuration screen, see figure 25 and table 8 an...

  • Page 35

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-15 menu item description 9. Password reuse count set whether the password must be changed or can be used again immediately; values are 0 (new password can be the same) or 1 (new password must be different) 10. Lockout after fai...

  • Page 36

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-16 • ui password: password that allows access through telnet, console, ssh, ftp, or sftp; 8 to 15 characters • ui password expires: yes or no • ui password expires in (days): 0 (never) to 365 • allow ui lockout of user: yes or ...

  • Page 37

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-17 system information - local unit 1. System name : 2. Contact : 3. Location : 4. Customer : 5. Information : : 6. Circuits : : 7. Service code : 8. Date-in-service : 9. Date-out-of-service : 10. Equipment type : 11. Equipment ...

  • Page 38

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-18 diagnostics local remote chassis/slot 4/3b 2/5 loopback switch setting: n/a n/a loop test mac address: 00 40 2a 80 58 32 00 40 2a 80 58 33 1) loopback option control software software 2) loopback state disabled disabled 3) s...

  • Page 39

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-19 4.8 system alarms use the system alarms screen to view alarms and faults on the l357. See figure 31. To view alarm status: 1. From the main menu, type 4 , "system alarms," and press . The system alarms screen appears. 2. Whe...

  • Page 40

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-20 layer 2 statistics local local remote remote user port ext port ext port user port link state up up up up speed/duplex 1000m/full 1000m/full 1000m/full 1000m/full frames sent 28207788 28319769 28200427 28200710 frames rcvd 2...

  • Page 41

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-21 system log description type username local date/time local user port link up trap system * 02-oct-2003 13:17:36.68 side band management online trap system * 02-oct-2003 15:28:15.80 log initialized trap system * 02-oct-2003 1...

  • Page 42

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-22 item definition 5) modem/slip/ppp baud rate select the baud rate, 9600, 19200, 38400, 57600, or 115200 bps for the modem/slip/ppp serial port (standalone enclosure, only) 6) modem initialization string the default string is ...

  • Page 43

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-23 4.11.2 static arp table use the static arp table to set specific ip and mac addresses for up to 10 ports. See figure 36. Static arp table ip address mac address port 1. 172.16.2.7 00-90-37-56-6c-34 2. 172.16.3.23 00-7c-25-33...

  • Page 44

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-24 4.12 software upgrade use the software upgrade report and menu screen to check the current version of the firmware and upgrade it and the remote l357, if necessary. To access the software upgrade screen and check the softwar...

  • Page 45

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-25 2. At the software upgrade menu, type 3 , "copy software from source unit to destination unit," and press . 3. At the prompt, select the source, which is the inactive bank for the local module, then select the destination, w...

  • Page 46

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 4-26.

  • Page 47: Chapter 5

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 5-1 chapter 5 maintenance and troubleshooting 5.1 general maintenance well-maintained components and clearly identified cables help assure optimum system operation. Damaged fiber cables and dirty connectors are a common source of...

  • Page 48

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 5-2 5.1.3 measure transmitter output power to measure the output power, follow these steps: 1. Clean the connectors on the fiber optic test cable, then plug it in to the tx connector on the l357. 2. Warm up each component for at ...

  • Page 49

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 5-3 5.1.5 measure fiber link attenuation determine and record link attenuation before starting normal link traffic. The attenuation factor identifies potential problems with links that are on the threshold of receiver limitations...

  • Page 50

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 5-4 5.2.2 new installation on new installations, make sure that all steps in chapter 2 are complete: 1. Check that the sta led is green. 2. Check that the fiber type (multimode or single mode) matches the l357 optical mode. 3. Ma...

  • Page 51: Chapter 6

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 6-1 chapter 6 specifications see also the specifications for the chassis or standalone enclosure. 6.1 l357 specifications physical specifications dimensions: 3.0"h x 1.0"w x 9.0"d (7.6 cm x 2.5 cm x 22.8 cm) weight: 0.3 lb. (0.13...

  • Page 52

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 6-2 1000base-t to 1000 mbps bidi interfaces user port: 10/100/1000m utp rj45 l357-1354 single fiber 1000 mbps 1310 nm 20 km l357-1564 single fiber 1000 mbps 1550 nm 20 km 1000base-t to 1000 mbps cwdm optical interfaces user port:...

  • Page 53

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 6-3 1000base-lx to bidi user port: 1000m lx 1310 nm sm 7 db sc l357-3354 single fiber 1000 mbps 1310 nm sm 20 km l357-3564 single fiber 1000 mbps 1550 nm sm 20 km 1000base-sx to 1000 mbps cwdm optical interfaces user port: 1000m ...

  • Page 54

    Edgeaccess universal chassis system l357 gigabit ethernet service unit 6-4.

  • Page 55: Appendix A

    Edgeaccess universal chassis system l357 gigabit ethernet service unit a-1 appendix a warranty limited lifetime warranty effective july 1, 2005 and after, canoga perkins warrants that, at the time of sale, and, for its lifetime, with certain exceptions noted below, every canoga perkins' labeled prod...

  • Page 56

    Edgeaccess universal chassis system l357 gigabit ethernet service unit a-2 limitations canoga perkins may at its sole discretion modify its limited warranty at any time and from time to time. Other than those expressly stated herein, there are no other warranties of any kind, expressed or implied, a...

  • Page 57: Appendix B

    Edgeaccess universal chassis system l357 gigabit ethernet service unit b-1 appendix b acronym and abbreviation list bam bus access module cim chassis interconnect module dmm domain management module fpga field programmable gate array lle link loss echo llf link loss forwarding lnk link mbps megabits...