    Chauvet, 3000 n 29 th ct, hollywood, fl 33020 u.S.A (800) 762-1084 – (954) 929-1115 fax (954) 929-5560 www.Chauvetlighting.Com 2005-01-31/12:52 art-150w spectrum™ 150w art-252w spectrum™ 252w user manual this manual includes instructions and overview on the following 2 chauvet products; art-150w and...

  • Page 2: Able Of

    Art-150w & art-252w user manual 2 2005-01-31/12:52 t able of c ontent table of content....................................................................................................................................................... 2 before you begin...............................................

  • Page 3: Efore

    Art-150w & art-252w user manual 3 2005-01-31/12:52 b efore y ou b egin what is included art-150w – spectrum™ 150w or art-252w – spectrum™ 252w & foot brackets power cord attached with bare ends msd-250 or cdm-150 discharge lamp warranty card & manual unpacking instructions immediately upon receiving...

  • Page 4: Ntroduction

    Art-150w & art-252w user manual 4 2005-01-31/12:52 i ntroduction technical features • 1 channel dmx controlled exterior color wash • 2 color system creates 15 colors plus white features • durable and weatherproof ip-55 rated housing • low noise operation • 4 built-in stand-alone programs with varyin...

  • Page 5

    Introduction art-150w & art-252w user manual 5 2005-01-31/12:52 product overview segment buttons i/o panel overview b uttons i/o p anel menu toggles programming functions dmx out & in dmx-512 connectors ( - ) steps backward through menu functions ( + ) steps forward through menu functions enter conf...

  • Page 6: Etup

    Art-150w & art-252w user manual 6 2005-01-31/12:52 1 2 3 6,7 s etup lamp you will need to install a lamp prior to the initial operation of the fixture. Warning! When replacing the lamp, please wait 15 minutes after powering down to allow the unit to cool down! Always disconnect from main power prior...

  • Page 7

    Setup art-150w & art-252w user manual 7 2005-01-31/12:52 1 s1 l am p i n st al l at i o n ( ar t - 2 5 2 w ) 1) remove the lamp back cover by removing the 4 screws located on rear of the head as illustrated (s1). 2) with lamp socket plate out and the lamp accessible, if replacing the lamp, remove ol...

  • Page 8

    Setup art-150w & art-252w user manual 8 2005-01-31/12:52 art-150w art-252w do not tilt beyond -90° and +90° as illustrated. Installation o r i e n t at i o n this fixture is designed to be installed upright at all times. It achieves an ingress protection rating of 55 only when the fixture’s base is ...

  • Page 9

    Setup art-150w & art-252w user manual 9 2005-01-31/12:52 lamp alignment screws even out this plate by turning the lamp alignment screws, prior to lamp optimization. This will provide you a good starting point. Safety precautions! • check your power cables carefully to ensure that there are no cuts o...

  • Page 10: Perating

    Art-150w & art-252w user manual 10 2005-01-31/12:52 o perating i nstructions menu navigation to select any of the pre-set functions, press the menu button until the desired function is shown on the display. Select the function by pressing the enter button and the display will blink. Use the down and...

  • Page 11

    Operating instructions art-150w & art-252w user manual 11 2005-01-31/12:52 optional daisy chain connection also applies to dmx-512 control. St an d - al o n e stand-alone is an independent fixture operating state which basically means without the use of any controlling device. The spectrum™ exterior...

  • Page 12

    Operating instructions art-150w & art-252w user manual 12 2005-01-31/12:52 menu functions dmx-512 addressing {addr} this mode enables the use of a universal dmx controller device. Each fixture requires a "start address" from 1 to 511. A fixture requiring one or more channels for control begins to re...

  • Page 13

    Operating instructions art-150w & art-252w user manual 13 2005-01-31/12:52 segment display configurations {led} the led segment display can be set to off after 8 seconds of no menu activity. The led will display again as soon as the menu is accessed by pressing any of the buttons. T u r n i n g t h ...

  • Page 14

    Art-150w & art-252w user manual 14 2005-01-31/12:52 spectrum color™ (optional dedicated controller) the art-1con is a user friendly dedicated controller for the spectrum architectural exterior wash. It allows the user to select manually any one of 10 colors on buttons or any of the 15 available colo...

  • Page 15: Ppendix

    Art-150w & art-252w user manual 15 2005-01-31/12:52 a ppendix dmx primer there are 512 channels in a dmx-512 connection. Channels may be assigned in any manner. A fixture capable of receiving dmx-512 will require one or a number of sequential channels. The user must assign a starting address on the ...

  • Page 16

    Appendix art-150w & art-252w user manual 16 2005-01-31/12:52 dmx channel values c hannel v alue f unction 1 000 007 008 015 016 022 023 030 031 037 038 045 046 052 053 060 061 067 068 075 076 082 083 090 091 097 098 105 106 112 113 120 121 127 128 247 248 255 colors blackout white ct-3200°k red ct &...

  • Page 17

    Appendix art-150w & art-252w user manual 17 2005-01-31/12:52 maintenance to maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a mo...

  • Page 18

    Appendix art-150w & art-252w user manual 18 2005-01-31/12:52 general troubleshooting applies to symptom solution(s) lights foggers & snow controllers dimmers & chaser auto shut off check fan thermal switch reset beam is very dim or not bright clean optical system or replace lamp check 220/110v switc...

  • Page 19

    Appendix art-150w & art-252w user manual 19 2005-01-31/12:52 technical specifications weight & dimensions (art-150w).......................................................................................................................................... Length..........................................