Chauvet EZrail RGBA User Manual

Manual is about: Linear, RGBA cable-free fixture includes battery power and goes anywhere light is needed

Summary of EZrail RGBA

  • Page 1

    User manual.

  • Page 2: Able Of

    Page 2 of 22 ezrail™ rgba user manual t able of c ontents 1. Before you begin ...........................................................................................................3 what is included ...................................................................................................

  • Page 3: Efore

    Ezrail™ rgba user manual page 3 of 22 1. B efore y ou b egin what is included · ezrail™ rgba · power cord · hanging bracket with mounting hardware · infrared remote control (irc) · warranty card · quick reference guide · 2 l-brackets unpacking instructions carefully unpack the product immediately an...

  • Page 4

    Page 4 of 22 ezrail™ rgba user manual product at a glance use on dimmer x auto programs p outdoor use x auto-ranging power supply p sound-activated p replaceable fuse p dmx p user-serviceable x master/slave p safety notes these notes include important information about the mounting, usage, and maint...

  • Page 5: Ntroduction

    Ezrail™ rgba user manual page 5 of 22 2. I ntroduction overview back panel view display safety loop power in fuse holder dmx out dmx in power out microphone control buttons power switch battery charged green indicator light battery charging red indicator light.

  • Page 6

    Page 6 of 22 ezrail™ rgba user manual dimensions 19.9 in 505 mm 6.1 in 155 mm 2.9 in 73 mm.

  • Page 7: Etup

    Ezrail™ rgba user manual page 7 of 22 3. S etup ac power the ezrail™ rgba has an auto-ranging power supply and it can work with an input voltage range of 100~240 vac, 50/60 hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on ...

  • Page 8

    Page 8 of 22 ezrail™ rgba user manual fuse replacement disconnect the product from power before replacing the fuse. 1. Disconnect the product from power. 2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder. 3. Pry the fuse holder out of the housing. 4. Remove the blown fuse ...

  • Page 9

    Ezrail™ rgba user manual page 9 of 22 power linking the product provides power linking via the edison/iec outlet located in the back of the unit. Power linking diagram you can power link up to 32 ezrail™ rgba units on 120 vac or up to 64 ezrail™ rgba units on 230 vac. The power linking diagram shown...

  • Page 10

    Page 10 of 22 ezrail™ rgba user manual mounting before mounting the product, read and follow the safety recommendations indicated in the safety notes. Orientation the ezrail™ rgba may be mounted in any position; however, make sure adequate ventilation is provided around the product rigging · before ...

  • Page 11: Peration

    Ezrail™ rgba user manual page 11 of 22 4. O peration control panel operation to access the control panel functions, use the four buttons located underneath the display. Button function selects an operation mode or backs out of the current menu option scrolls up the list of options or selects a highe...

  • Page 12

    Page 12 of 22 ezrail™ rgba user manual configuration (dmx) set the product in dmx mode to control with a dmx controller. 1. Connect the product to a suitable power outlet. 2. Turn the product on. 3. Connect a dmx cable from the dmx output of the dmx controller to the dmx input socket on the product....

  • Page 13

    Ezrail™ rgba user manual page 13 of 22 dmx channel modes, assignments, and values 18-channel channel function value setting section 1 dimmer 000 ó 255 0–100% 2 red 000 ó 255 0–100% 1 3 green 000 ó 255 0–100% 4 blue 000 ó 255 0–100% 5 amber 000 ó 255 0–100% 6 red 000 ó 255 0–100% 2 7 green 000 ó 255 ...

  • Page 14

    Page 14 of 22 ezrail™ rgba user manual 8-channel channel function value setting 1 dimmer 000 ó 255 0–100% 2 red 000 ó 255 0–100% 3 green 000 ó 255 0–100% 4 blue 000 ó 255 0–100% 5 amber 000 ó 255 0–100% 6 auto programs 000 ó 007 no function 008 ó 015 red 016 ó 023 green 024 ó 031 blue 032 ó 039 ambe...

  • Page 15

    Ezrail™ rgba user manual page 15 of 22 4-channel channel function value setting 1 red 000 ó 255 0–100% 2 green 000 ó 255 0–100% 3 blue 000 ó 255 0–100% 4 amber 000 ó 255 0–100% 2-channel channel function value setting 1 auto programs 000 ó 007 no function 008 ó 015 red 016 ó 023 green 024 ó 031 blue...

  • Page 16

    Page 16 of 22 ezrail™ rgba user manual configuration (standalone) set the product in one of the standalone modes to control without a dmx controller. 1. Connect the product to a suitable power outlet. 2. Turn the product on. Never connect a product that is operating in any standalone mode (either st...

  • Page 17

    Ezrail™ rgba user manual page 17 of 22 auto program to enable the auto program, do the following: 1. Press repeatedly until auto shows on the display. 2. Press and n 1–n100 (number of loops) show on the display. 3. Use or to select the desired setting. 4. Press and run speed options sp 1–sp99, spfl ...

  • Page 18

    Page 18 of 22 ezrail™ rgba user manual irc operation note: make sure to point the irc directly at the receiver on the front of the product. Automatic mode automatic mode will enable you to run the automatic programs on the product. To turn on automatic mode: 1. Press on the irc. 2. Press or to choos...

  • Page 19

    Ezrail™ rgba user manual page 19 of 22 master/slave mode the master/slave mode allows a single ezrail™ rgba unit (the “master”) to control the actions of one or more ezrail™ rgba units (the “slaves”) without the need of a dmx controller. The master unit will be set to operate in either a preset prog...

  • Page 20: Echnical

    Page 20 of 22 ezrail™ rgba user manual 5. T echnical i nformation product maintenance dust build-up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and/or mechanical wear. To maintain optimum performance and minimize wear, clean the p...

  • Page 21: Echnical

    Ezrail™ rgba user manual page 21 of 22 6. T echnical s pecifications dimensions and weight length width height weight 19.9 in (505 mm) 2.9 in (73 mm) 6.1 in (155 mm) 5.6 lb (2.6 kg) note: dimensions in inches rounded to the nearest decimal digit. Power power supply type range voltage selection switc...

  • Page 22

    Page 22 of 22 ezrail™ rgba user manual to return a product or request support: · in the u.S., contact chauvet® world headquarters (see below). · in the uk or ireland, contact chauvet® europe ltd. (see below). · in any other country, do not contact chauvet®. Contact your distributor. See www.Chauvetl...