Chauvet LED PAR 64 TRI-B User Manual

Manual is about: Chauvet Work Light - LED Worklight User Manual

Summary of LED PAR 64 TRI-B

  • Page 1

    Led par 64 tri-b user manual.

  • Page 2: Able Of

    Chauvet®, 2013, all rights reserved information and specifications in this user manual are subject to change without notice. Chauvet® assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual. T able of c ontents 1. Before you begin............................

  • Page 3: Efore

    1. Before you begin 3 6/21/2013 4:33 pm 1. B efore y ou b egin what is included · 1 x led par 64 tri-b · 1 x gel frame · 1 x warranty card · 1 x user manual unpacking instructions immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are prese...

  • Page 4

    1. Before you begin 4 6/21/2013 4:33 pm safety instructions · please keep this user manual for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. · always make sure that you are connecting to the proper voltage, and that the line volta...

  • Page 5: Ntroduction

    2. Introduction 5 6/21/2013 4:33 pm 2. I ntroduction product overview dmx in power in microphone sensitivity adjustment knob microphone bracket adjustment knob power out fuseholder control panel (led display) dmx out hanging bracket secondary bracket.

  • Page 6: Etup

    3. Setup 6 6/21/2013 4:33 pm 3. S etup ac power this fixture runs on 100~240 vac, 50/60 hz. Before powering on the unit, make sure the line voltage to which you are connecting it is within the range of accepted voltages. To determine the power requirements for a particular fixture, see the label aff...

  • Page 7

    3. Setup 7 6/21/2013 4:33 pm mounting orientation mount the led par 64 tri-b in any position, provided there is adequate room for ventilation. Rigging be sure that the structure can support the weight of the fixture. Please see the “technical specifications” section of this manual for a detailed wei...

  • Page 8: Perating

    4. Operating instructions 8 6/21/2013 4:33 pm 4. O perating i nstructions configuring the starting address the led par 64 tri-b fixture uses up to seven dmx channels. The highest channel that the fixture may be set to in order to function properly is 506. Any address higher than this will prevent ac...

  • Page 9

    4. Operating instructions 9 6/21/2013 4:33 pm menu map m ain f unction s ub -f unction s election s ub -s election i nstruction p-- p1 7 color switching - select between 2 switching and 2 fading built-in programs p2 7 color fading p3 3 color switching p4 3 color fading p5 7 color sound active use th...

  • Page 10

    4. Operating instructions 10 6/21/2013 4:33 pm dmx operation this is the operating mode which will allow for control with an external dmx controller. You must set the starting address for this mode. If this is your first time using dmx, then it is recommended that you refer to the “dmx primer” secti...

  • Page 11

    4. Operating instructions 11 6/21/2013 4:33 pm standalone automatic this fixture has preprogrammed chases. These are accessed via the control panel, and the speed may be adjusted for the chases. Please see the instructions below for further explanation. 1. Press until p-- appears on the led screen. ...

  • Page 12

    4. Operating instructions 12 6/21/2013 4:33 pm dmx channel values 7-channel personality c hannel v alue f unction 1 000 ó 255 red dimmer: 0%~100% 2 000 ó 255 green dimmer: 0%~100% 3 000 ó 255 blue dimmer: 0%~100% 4 000 ó 015 016 ó 255 color macros no function color macros 5 000 ó 255 speed (ch.6 @ v...

  • Page 13: Ppendix

    5. Appendix 13 6/21/2013 4:33 pm 5. A ppendix general troubleshooting s ymptom p ossible c ause ( s ) p ossible a ction ( s ) breaker/fuse keeps blowing · excessive circuit load · check total load placed on the electrical circuit. · short circuit along the power wires · check for a short in the elec...

  • Page 14

    5. Appendix 14 6/21/2013 4:33 pm dmx primer there are 512 channels in a dmx connection. A fixture capable of receiving dmx will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There ar...

  • Page 15

    5. Appendix 15 6/21/2013 4:33 pm cable connectors cabling must have a male xlr connector on one end and a female xlr connector on the other end. Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a ground loop, and your fixture may perform errati...

  • Page 16

    5. Appendix 16 6/21/2013 4:33 pm 3-pin to 5-pin conversion chart if you use a controller with a 5-pin dmx output connector, you will need to use a 5-pin to 3-pin adapter. The chart below details a proper cable conversion: 3-p in to 5-p in c onversion c hart conductor 3-pin female (output) 5-pin male...

  • Page 17

    5. Appendix 17 6/21/2013 4:33 pm general maintenance to maintain optimum performance and minimize wear, fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up ...

  • Page 18: Echnical

    T echnical s pecifications weight & dimensions length ..............................................................................................................11.9 in (302 mm) width ....................................................................................................................

  • Page 19: Ontact

    C ontact u s world wide general information chauvet® 5200 nw 108 th ave sunrise, fl 33351 voice: 954.557.4455 fax: 954.929.5560 toll free: 800.762.1084 technical support chauvet® 5200 nw 108 th ave sunrise, fl 33351 voice: 954.577.4455 (press 4) fax: 954.929.5560 (attention: service) world wide web ...