- DL manuals
- Chauvet
- Light Fixture
- LED Shadow TFX-UVLED
- User Manual
Chauvet LED Shadow TFX-UVLED User Manual
Summary of LED Shadow TFX-UVLED
Page 1
Chauvet, 3000 n 29 th ct, hollywood, fl 33020 u.S.A (800) 762-1084 – (954) 929-1115 fax (954) 929-5560 www.Chauvetlighting.Com 2006-10-11 / 12:19 led shadow™ tfx-uvled user manual.
Page 2: Table of Contents
Tfx-uvled user manual 2 2006-10-11 / 12:19 ©chauvet, 2006, all rights reserved information and specifications in this user manual are subject to change without notice. Chauvet assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual. Table of contents 1. B...
Page 3: 1. Before You Begin
Tfx-uvled user manual 3 2006-10-11 / 12:19 1. Before you begin unpacking instructions immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packin...
Page 4: Important Safety Information
Before you begin tfx-uvled user manual 4 2006-10-11 / 12:19 important safety information this product is designed for professional use. It is not intended for use in a household environment. This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet radi...
Page 5: 2. Introduction
Tfx-uvled user manual 5 2006-10-11 / 12:19 1 2 3 dimmer 000~029 intensity 0% ~ 100% preset programs (1 ~ 6) 030~209 speed slow ~ fast sound mode 225~255 no function intensity 100% ~ 0% control modes & options (rows) dmx channel (columns) for a detailed view of dmx values turn to the appendix section...
Page 6: Product Overview
Introduction tfx-uvled user manual 6 2006-10-11 / 12:19 dmx input dip-switches dmx addressing iec plug for ac input & fuse compartment dmx output led front panel hanging yoke audio sensitivity rotary knob red led: power indicator blue led: signal indicator power link out flush mounting bracket produ...
Page 7: 3. Setup
Tfx-uvled user manual 7 2006-10-11 / 12:19 hanging clamp flush mounting bracket 3. Setup ac power warning! Verify that the power requirement label on your unit matches the line voltage applied. All fixtures must be connected to circuits with a suitable earth ground. • to determine the power requirem...
Page 8: Fixture Linking
Setup tfx-uvled user manual 8 2006-10-11 / 12:19 fixture linking you will need a serial data link to run light shows of one or more fixtures using a dmx-512 controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required ...
Page 9
Setup tfx-uvled user manual 9 2006-10-11 / 12:19 this drawing provides a general illustration of the dmx input/output panel of a lighting fixture. Universal dmx controller continue the link often, the setup for master-slave and standalone operation requires that the first fixture in the chain be ini...
Page 10: 4. Operating Instructions
Tfx-uvled user manual 10 2006-10-11 / 12:19 1 2 3 4 5 6 7 8 9 10 1 2 4 8 16 32 64 128 256 option sound auto on 4. Operating instructions the tfx-uvled is a dmx-512 controllable, flash uv led panel made up of highly efficient and super bright uv leds. The tfx-uvled can operate in stand-alone, master/...
Page 11: Dmx Control Mode
Operating instructions tfx-uvled user manual 11 2006-10-11 / 12:19 dmx control mode the tfx-uvled can be operated from a dmx controller. This control mode environment gives the user the greatest flexibility when it comes to customizing or creating a show by enabling the control of each individual tr...
Page 12: 5. Appendix
Tfx-uvled user manual 12 2006-10-11 / 12:19 5. Appendix dmx primer there are 512 channels in a dmx-512 connection. Channels may be assigned in any manner. A fixture capable of receiving dmx-512 will require one or a number of sequential channels. The user must assign a starting address on the fixtur...
Page 13
Appendix tfx-uvled user manual 13 2006-10-11 / 12:19 unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components. Clean all glass when the fixture is cold with a mild solution of glass cleaner or isopropyl alcohol and ...
Page 14
Appendix tfx-uvled user manual 14 2006-10-11 / 12:19 binary addressing quick reference chart dmx & binary address quick reference chart dip-switch position dmx dip-switch set #9 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0=off #8 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 1=on #7 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 x=off or ...
Page 15: Dmx Channel Values
Appendix tfx-uvled user manual 15 2006-10-11 / 12:19 dmx channel values note! Please read all instructions carefully on fixture dmx control mode and addressing. Dmx channels 2, and 3 functions are determined by the current settings of channel 1. For example, while channel 1 is set between 000 and 02...
Page 16: Technical Specifications
Appendix tfx-uvled user manual 16 2006-10-11 / 12:19 technical specifications weight & dimensions length........................................................................................................................ 355.6 mm (14.0 in) width .....................................................