  • Page 1

    Snapshot ok on dimmer outdoor ok sound activated dmx/master/slave 115v/230v switch replaceable fuse user serviceable duty cycle q-wash led™ user manual chauvet, 3000 n 29 th ct, hollywood, fl 33020 u.S.A (800) 762-1084 – (954) 929-1115 fax (954) 929-5560 www.Chauvetlighting.Com.

  • Page 2: Able of

    T able of c ontents 1. Before you begin....................................................................................................................................................... 3 u npacking i nstructions .....................................................................................

  • Page 3: Efore

    1. B efore y ou b egin unpacking instructions immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts a...

  • Page 4

    Important safety information this product is designed for professional use. It is not intended for use in a household environment. This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet radiation, lamp explosion, and injury from falls. Read this manu...

  • Page 5: Ntroduction

    2. I ntroduction features • 10-channel dmx-512 led moving yoke color wash • pan: 540 o / tilt: 270 o • rgb color mixing • variable electronic strobe • variable electronic dimmer (0 - 100%) • remote fixture reset and vector speed channel ad d i t i o n a l f e a t u r e s • extremely bright 1w leds •...

  • Page 6

    Product overview yoke base head dmx ou t dmx in 110v~230 v powe r in pu t powe r mi c mod e up dow n ente r fus e dmx connectors control buttons iec power connector power switch microphone lcd display fuse voltage select switch q-wash led user manual 6 revised: 2006-12-11 11:35:30

  • Page 7: Etup

    3. S etup ac power warning! Verify that the voltage select switch on your unit matches the line voltage applied. Damage to your fixture may result if the line voltage applied does not match the voltage indicated on the voltage selector switch. All fixtures must be connected to circuits with a suitab...

  • Page 8

    Fixture linking you will need a serial data link to run light shows of one or more fixtures using a dmx-512 controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determi...

  • Page 9

    3 - p i n t o 5 - p i n c o n ve r s i o n c h a r t note! If you use a controller with a 5 pin dmx output connector, you will need to use a 5 pin to 3 pin adapter. Chauvet model no: dmx5m. The chart below details a proper cable conversion: 3 p in to 5 p in c onversion c hart conductor 3 pin female ...

  • Page 10: Perating

    4. O perating i nstructions navigating the control panel access control panel functions using the four panel buttons located directly underneath the lcd display. Mode up down enter button function used to access the menu or to return to a previous menu option scrolls through menu options in ascendin...

  • Page 11

    Slave mode operation menu run run slave this mode allows the unit to operate as the slave of another master unit. Up to 32 fixtures may be linked together in this mode. 1) in the menu, select “run”. Next, scroll through until “slave” is displayed, and select it. Press until “run” is displayed on the...

  • Page 12

    Additional menu options this fixture can be customized in several different ways at the discretion of the user. This section details how to change the fan speed, invert the pan, invert the tilt, reset the fixture, and restore the fixture to factory default settings. To change the fan speed : 1) in t...

  • Page 13: Ppendix

    5. A ppendix dmx primer there are 512 channels in a dmx-512 connection, though all 512 channels do not need to be used. Channels may be assigned in any manner. A fixture capable of receiving dmx-512 will require one or a number of sequential channels. The user must assign a starting address on the f...

  • Page 14

    Returns procedure returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a return merchandise authorization number (ra #). Products returned without an ra # will be refused. Call chauvet and request an ra # prior to s...

  • Page 15

    Menu map menu menu menu options menu address menu run edit prg run auto1 run auto2 run sound1 run sound2 address 001-499 fan speed invert pan invert tilt reset load default edit program step 001-100 confirm reset pan 000-255 tilt 000-255 red 000-255 green 000-255 blue 000-255 strobe 000-255 time 000...

  • Page 16

    Technical specifications weight & dimensions length........................................................................................................................... 14.0 in (356 mm) width .........................................................................................................