Chauvet S-Mover User Manual

Other manuals for S-Mover: Supplementary Manual, User Manual
Manual is about: 8-channel DMX-512 stage mover

Summary of S-Mover

  • Page 1

    Snapshot ok on dimmer outdoor ok sound activated dmx512 master/slave 115v/230v switch replaceable fuse user serviceable duty cycle s-mover stage mover™ user manual chauvet, 3000 n 29 th ct, hollywood, fl 33020 u.S.A. (800) 762-1084 – (954) 929-1115 fax (954) 929-5560 www.Chauvetlighting.Com.

  • Page 2: Able of

    T able of c ontents 1. Before you begin....................................................................................................................................................... 3 w hat is included ............................................................................................

  • Page 3: Efore

    1. B efore y ou b egin what is included ¾ 1 x stage mover™ ¾ power cord ¾ warranty card ¾ user manual unpacking instructions immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify th...

  • Page 4

    Safety instructions please read these instructions carefully, which includes important information about the installation, usage and maintenance of this product. • please keep this user guide for future consultation. If you sell the unit to another user, be sure that they also receive this instructi...

  • Page 5: Ntroduction

    2. I ntroduction features • 8-channel dmx-512 stage mover • pan: 540° / tilt: 270° • variable electronic dimmer (0 – 100%) • remote fixture reset, lamp on/off & vector speed channel ad d i t i o n a l f e a t u r e s • automatic pan/tilt correction • built-in automatic programs via master/slave • bu...

  • Page 6

    Product overview yoke control panel head gel housing & protective screen carrying handle base voltage selector switch rear of base dmx input connector dmx output connector ac power input & fuse holder stage mover manual 6 2007-04-13/09:39.

  • Page 7: Etup

    3. S etup lamp optional 500w or 1000w lamps may be purchased from any chauvet dealer. Warning! When replacing the lamp, please wait 15 minutes after powering down to allow the unit to cool down! Always disconnect from main power prior to lamp replacement. Do not touch the envelope (glass area) of th...

  • Page 8

    Fixture linking you will need a serial data link to run light shows of one or more fixtures using a dmx-512 controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determi...

  • Page 9

    3 - p i n t o 5 - p i n c o n v e r s i o n c h a r t note! If you use a controller with a 5 pin dmx output connector, you will need to use a 5 pin to 3 pin adapter. Chauvet model no: dmx5m, or dmx5f. The chart below details a proper cable conversion: 3 p in to 5 p in c onversion c hart conductor 3 ...

  • Page 10: Perating

    Mounting o r i e n t a t i o n this fixture may be mounted in any position provided there is adequate room for ventilation. R i g g i n g it is important never to obstruct the fan or vents pathway. Mount the fixture using, a suitable “c” or “o” type clamp. Adjust the angle of the fixture by loosenin...

  • Page 11

    Menu map enu functions d escription m m enu o ption dmx: the fixture will be controlled by a dmx signal coming from a dmx controller. Ess must be selected, and can be set using the up and down the starting addr buttons. Stand alone – automatic: the built in programs will trigger automatically to a p...

  • Page 12

    T o s e t t h e t i l t t o i n v e r t i n g o r n o n - i n v e r t i n g : 1) press until is d ptions. Isplayed. 2) use the and buttons to scroll through the two o is non- inverting; is inverting. T o r e v e r s e t h e d i s p l a y : 1) de/esc> un press til or is displayed. Own> buttons to scr...

  • Page 13

    Master/slave mode (master sound, master auto): this mode will allow you to link up to 32 units together without a controller. 1) use standard dmx cables to daisy chain your units together via the dmx connector on the rear of the units. For longer cable runs we suggest a terminator at the last fixtur...

  • Page 14

    General troubleshooting applies to symptom solution(s) lights foggers & snow controllers dimmers & chaser auto shut off check fan thermal switch reset 9 beam is very dim or not bright clean optical system or replace lamp check 220/110v switch for proper setting 9 breaker/fuse keeps blowing check tot...

  • Page 15: Ppendix

    If you still have a problem after trying the above solutions, please contact chauvet technical support at the location on the next page. Technical support address: service dept. 3000 n 29th ct, hollywood, fl 33020 (u.S.A.) support (email): tech@chauvetlighting.Com telephone: (954) 929-1115 - (press ...

  • Page 16

    General maintenance to maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance a...

  • Page 17

    Technical specifications weight & dimensions length.............................................................................................................................. 14 in (356 mm) width ........................................................................................................