Concorde Battery BC-8000 Instruction manual - page 13
Page 12
Manual: BC-8000
9. To import DDR data into a spreadsheet, run the spreadsheet program and open the DDR CSV file.
DC POWER SUPPLY MODE
Danger:
Never leave the BC-8000 unattended while operating in the power supply mode.
The BC-8000 Power Supply Mode can be used to supply DC power to batteries that have built in battery chargers and or
isolation diodes. Consult the battery manufacturer for proper connections and voltage settings. Always use the correct
mating connectors. For any questions on setup or operation of the BC-8000 Power Supply contact:
support@cofko.com
When the BC-8000 is operating in the power supply mode, the BC-8000 DC output cord gray connector will
have voltage on the output terminals regardless if connected to anything.
1.
Place the BC-8000 on a stable surface and connect the AC power cord (4161-10) to AC power outlet. Connect
the DC output cord (4161-50) to the BC-8000 and the equipment to be powered.
Warning:
If an extension cord is used to connect the BC-8000 to the AC power source, make sure the
cord is properly sized for the AC current draw. Long power cords of insufficient wire gauge size can cause
excessive voltage drops in the cord. Always consult your local electric codes for guidance in proper sizing of the
extension cord.
Danger
: Never use an extension cord or power source that does not have a proper AC grounding
connection. Review your local AC power codes for proper grounding configurations.
2. Set the BC-8000 AC power switch to the ON position.
3. Using the UP or DOWN button, set the display to the PWR SUPPLY option. Then press NEXT.
4. Using the UP or DOWN button, adjust the output DC voltage to the proper level for the equipment being powered.
Then press NEXT.
Warning:
Always review the equipment manufacturer’s maximum input voltage level for safe operation.
Never exceed these settings.
5. Using the UP or DOWN button, set the maximum DC output amperage value. This setting should meet the maximum