    Condor instruments ltda. 17/05/2017 acttrust – user manual model: at0503 actstudio version: 1.0.6.0

  • Page 2: Index

    Copyright © 2013, condor instruments ltda. 2 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 index introduction ....................................................................................................... 5 indications of use..........................................................

  • Page 3

    Copyright © 2013, condor instruments ltda. 3 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 data analysis ................................................................................................ 36 sleep scoring .........................................................................

  • Page 4

    Copyright © 2013, condor instruments ltda. 4 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 applicable standards ...................................................................................... 81 manuf acturer’s declaration - electromagnetic immunity and emission ............ 82 sym...

  • Page 5: Introduction

    Copyright © 2013, condor instruments ltda. 5 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 introduction before using the device, read the user manual as a whole. Indications of use the acttrust is an ultra-compact, lightweight, wrist-worn activity, temperature and ambient light monitor th...

  • Page 6: Actdock

    Copyright © 2013, condor instruments ltda. 6 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 actdock description the actdock (common name: usb adapter) is composed of four parts, the lid, the base, the back cover and the pcb. This accessory is intended to adapt the usb pins in the acttrust ...

  • Page 7: Cleaning And Maintenance

    Copyright © 2013, condor instruments ltda. 7 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 cleaning and maintenance only clean using a damp cloth and mild soap. Notes: avoid contact with gasoline, benzine, thinner or acetone and, in case of contact with any of these substances, clean the ...

  • Page 8: Acttrust

    Copyright © 2013, condor instruments ltda. 8 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 1. Guarantee that the golden pins in both the dock and in the acttrust are aligned as shown. 2. Rotate de acttrust in order to dovetail it in dock. 3. Close the dock and pressure it until the click ...

  • Page 9: Actstudio Software

    Copyright © 2013, condor instruments ltda. 9 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 notes: avoid contact with gasoline, benzene, thinner or acetone and, in case of contact with any of these substances, wash the device with mild soap and water as soon as possible. Do not use abrasiv...

  • Page 10: Control Menu

    Copyright © 2013, condor instruments ltda. 10 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 control menu information device name of the connected device. Id unique identifier of the connected device. Battery charge status of the battery of the connected device and its power. Charging char...

  • Page 11

    Copyright © 2013, condor instruments ltda. 11 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 firmware version firmware version of the connected device. Power mode active or power down. Memory percentage of the memory used. Power mode label identifies whether the device is set to power down...

  • Page 12

    Copyright © 2013, condor instruments ltda. 12 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 log memory usage memory usage of the connected device. Erase button clears the data stored in the memory of the connected device. Read button read the data stored in the memory of the connected dev...

  • Page 13: Quick Operations Buttons

    Copyright © 2013, condor instruments ltda. 13 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 quick operations buttons there are 2 buttons in the control menu that do not add any new functionality to the actstudio software, but rather makes operations with the actstudio software quicker. Th...

  • Page 14: Support Menu

    Copyright © 2013, condor instruments ltda. 14 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 2. Read / save / power down: performs the same operation as if the user had pressed the buttons read (in the log section), save (in the log section) and enable (in the power down section) sequentia...

  • Page 15: Data Menu

    Copyright © 2013, condor instruments ltda. 15 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 data menu log list in the log list page, you can manage all logs stored in the database. In the log list page you can select a log to perform analyzes, edit its trial information (e.G. Subject name...

  • Page 16

    Copyright © 2013, condor instruments ltda. 16 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 note 2: this process may take a few seconds to complete (depends on the database size) because it will delete the disabled logs and will rebuild the database file. It will probably decrease the dat...

  • Page 17

    Copyright © 2013, condor instruments ltda. 17 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 note: when you are editing an "edited" log and tries to save it, you can choose if wants to create a new log from it or if wants to override the current log. Created at shows the date and time when...

  • Page 18

    Copyright © 2013, condor instruments ltda. 18 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 as the message explains, this process may take a few seconds to complete (it depends on the database size), and you need to wait until it finishes. Note: this option should be used when you have so...

  • Page 19: Data Import/export

    Copyright © 2013, condor instruments ltda. 19 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 data import/export period selection field used to select the period of the data to be filtered. Initial initial date and time of the sample. Final final date and time of the sample. Reset redefine ...

  • Page 20

    Copyright © 2013, condor instruments ltda. 20 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 change timezone field used to change the time zone of the entire period. Hours the field used to select the time zone. Apply add or subtract hours of the column date/time in the entire period. Rese...

  • Page 21

    Copyright © 2013, condor instruments ltda. 21 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 date format date and time field formatting when exported. Normal: date and time delimited by a space. Delimited: date and time delimited by the delimiter character (data delimiter) chosen. Custom: ...

  • Page 22: Sleep Diary

    Copyright © 2013, condor instruments ltda. 22 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 sleep diary in the sleep diary menu, the user can insert data from a manual sleep diary provided by the patient. This data can be used as a parameter to the sleep scoring algorithm. Data insertion ...

  • Page 23

    Copyright © 2013, condor instruments ltda. 23 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 import/export data field used to import or export data to text file. Import button to import the sleep diary data from a text file. Must be a text file exported by the sleep diary menu. Export butt...

  • Page 24: Light/dark Phase

    Copyright © 2013, condor instruments ltda. 24 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 light/dark phase form used to define parameters to be used in the sleep scoring and statistics menus. These parameters are basically used to define when the day starts and when it ends, and to defi...

  • Page 25

    Copyright © 2013, condor instruments ltda. 25 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 city the user can select a city. The cities will be automatically loaded when the user selects a state. By selecting a city the latitude and longitude will be automatically loaded, but you can alwa...

  • Page 26

    Copyright © 2013, condor instruments ltda. 26 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 configuring acttrust for an operation 1. The user must delete all data on the device used before starting a new sampling to maintain data consistency. In order to do so, click the erase button in t...

  • Page 27

    Copyright © 2013, condor instruments ltda. 27 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 3. It is advisable to synchronize the device time with the time of the user's computer in order to reduce any accumulated drift. To do this, click in the sync button on the time field. 4. It is adv...

  • Page 28

    Copyright © 2013, condor instruments ltda. 28 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 a message asking if you want to delete all the device data: and if you do not delete the device data, you will receive the following message: in this case, the configuration is not applied because ...

  • Page 29

    Copyright © 2013, condor instruments ltda. 29 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 putting acttrust into power down mode 1. In power mode field, click in the power down button. Make sure the field show’s power down. 2. It is recommended to wait until the acttrust’s battery is ful...

  • Page 30

    Copyright © 2013, condor instruments ltda. 30 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 3. Just remove the acttrust from the dock and it will already be in storage mode. In case it is reconnected to the dock, it will automatically come into the datalogger mode. If you want to check th...

  • Page 31: Extracting Acttrust Data

    Copyright © 2013, condor instruments ltda. 31 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 extracting acttrust data 1. Click the read button in the log field. Wait for the reading to be performed. The software will freeze while reading. When the log is completely loaded (100%) the actstu...

  • Page 32

    Copyright © 2013, condor instruments ltda. 32 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 2. Saving the log into the database. Every time you read a new data log from the device the following message will be shown: you can choose if wants to save the log into the database by clicking on...

  • Page 33

    Copyright © 2013, condor instruments ltda. 33 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 4. Select the period of the data to be exported in period selection field 5. Select the data to be exported in the data selection field. 6. Select the types of log to be included in the exported fi...

  • Page 34: Solving Data Problems

    Copyright © 2013, condor instruments ltda. 34 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 11. In the date format field, select which format will be used for the date and time of exported logs. 12. Select include header if you want to include a header in the exported data. Press the save...

  • Page 35

    Copyright © 2013, condor instruments ltda. 35 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 if the actstudio find a gap in the data, the following message will be shown: the user can choose to fill the gap with null values (0) or not. Note: when the data are loaded to process analysis, we...

  • Page 36: Data Analysis

    Copyright © 2013, condor instruments ltda. 36 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 data analysis on this menu the data extracted in the previous steps can be analyzed and additional information can be attached. Sleep scoring the sleep scoring can be plotted and edited for publish...

  • Page 37

    Copyright © 2013, condor instruments ltda. 37 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 ext temperature select if external temperature data will or will not be shown in the graphs. Red light select if red light data will or will not be shown in the graphs. Green light select if green ...

  • Page 38: Action Menu

    Copyright © 2013, condor instruments ltda. 38 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 action menu the action menu is shown when the user clicks the right mouse button on the sleep scoring graph. 1. Menu used to change the sleep scoring state where the user has clicked. Awake (empty)...

  • Page 39: Editing An Editable Area

    Copyright © 2013, condor instruments ltda. 39 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 editing an editable area to edit an editable area just double click on the name or color of the editable region (in the curves menu) and the following window dialog will be shown: you can select a ...

  • Page 40

    Copyright © 2013, condor instruments ltda. 40 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 when you include a sticky note into a graph it will receive a little point on the left upper corner (1) and it will also show a tooltip with the note content when you stop with the mouse cursor on ...

  • Page 41: Sleep Scoring Settings

    Copyright © 2013, condor instruments ltda. 41 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 sleep scoring settings the sleep scoring settings window can be used to configure the sleep scoring algorithms and the respective parameters. Selection of algorithm sleep/awake algorithm detection ...

  • Page 42

    Copyright © 2013, condor instruments ltda. 42 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 sleeping algorithm this option is not in use at the moment. Source the data source to be used to define the sleeping state. N of previous epochs the number of previous epochs to be considered in th...

  • Page 43

    Copyright © 2013, condor instruments ltda. 43 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 buttons reset this button will reset the settings to the default options. Note: these options will not be saved until the user press the “save” button. Load this button will load the settings alrea...

  • Page 44: Statistics

    Copyright © 2013, condor instruments ltda. 44 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 statistics this page will calculate and show the daily analyses of sleep performance. To refresh the information in this page just click at the calculate statistics button in the main menu. Note: o...

  • Page 45

    Copyright © 2013, condor instruments ltda. 45 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 select all rows select all rows (checkboxes) in the statistics table and updates the summary statistics. Deselect all rows deselect all rows (checkboxes) in the statistics table and updates the sum...

  • Page 46: Daily Statistics

    Copyright © 2013, condor instruments ltda. 46 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 daily statistics the daily statistics analysis are calculated based on the results of the statistics analysis. It gets the results from the statistics table and the parameters defined in the "light...

  • Page 47

    Copyright © 2013, condor instruments ltda. 47 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 percentage of main sleep episodes the percentage of the main sleep episodes of each day (main sleep episodes total time / total sleep time). Number of secondary sleep episodes the number of sleep e...

  • Page 48: Chronobiology

    Copyright © 2013, condor instruments ltda. 48 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 chronobiology this page will calculate the chronobiology functions: m10, l5, ra, intradaily variability (iv) and interdaily stability (is). The chronobiology functions were developed based on the r...

  • Page 49

    Copyright © 2013, condor instruments ltda. 49 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 parameters selection field used to select some parameters to the chronobiology functions. M10 and l5 parameters calculate method entire period: the m10 and l5 will be calculated based on the entire...

  • Page 50

    Copyright © 2013, condor instruments ltda. 50 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 iv parameters method 1 this method does not use any offwrist value in the calculation. One point of offwrist is enough to consider all period as offwrist. Method 2 this method calculates the averag...

  • Page 51: Actogram

    Copyright © 2013, condor instruments ltda. 51 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 actogram the actogram shows a time series along two time axes. The x axis represents the period (24 hours – single plot or 48 hours – double plot) and the y axis represents the selected data in day...

  • Page 52

    Copyright © 2013, condor instruments ltda. 52 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 plot type double plot: this option will plot two days (side by side) per line. Single plot: this option will plot only one day per line. Data type original data: it will plot the original data in t...

  • Page 53

    Copyright © 2013, condor instruments ltda. 53 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 data type example original data binary normalized grayscale important the light/dark phases will be printed based on the parameters defined in the light/dark phase page. When using the temperature ...

  • Page 54: Periodogram

    Copyright © 2013, condor instruments ltda. 54 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 periodogram the periodogram was developed based on the sokolove matlab function which in turn was created based on the work entitled "the chi square periodogram: its utility for analysis of circadi...

  • Page 55

    Copyright © 2013, condor instruments ltda. 55 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 period and data selection field used to select the parameters that will be used at the periodogram generation. Periodogram parameters initial date select the initial date. Initial time select the i...

  • Page 56

    Copyright © 2013, condor instruments ltda. 56 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 curves periodogram results select if the periodogram results curve will or will not be shown in the graph. Simple moving average select if the simple moving average curve will or will not be shown ...

  • Page 57

    Copyright © 2013, condor instruments ltda. 57 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 when calculating the periodogram analysis, the actstudio may show the following alert messages: usually, this message appears when the user selects a short time period, but it can also happen when ...

  • Page 58: Cosinor

    Copyright © 2013, condor instruments ltda. 58 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 cosinor the cosinor analysis uses the least squares method to fit a sine wave to a time series. Cosinor analysis is often used in the analysis of biologic time series that demonstrate predictible r...

  • Page 59

    Copyright © 2013, condor instruments ltda. 59 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 period and data selection field used to select the period and the data that will be used in the calculation. Initial date select the initial date. Initial time select the initial time. Days select ...

  • Page 60

    Copyright © 2013, condor instruments ltda. 60 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 results mesor shows the mesor result, that is the average cylce value. Amplitude shows the amplitude result. Half the distance between peaks of the fitted waveform. Acrophase shows the acrophase re...

  • Page 61

    Copyright © 2013, condor instruments ltda. 61 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 the following message can be shown when the user tries to calculate the cosinor analysis: this message represents that the confidence limits for amplitude and acrophase do not have calculable bound...

  • Page 62: Tab System

    Copyright © 2013, condor instruments ltda. 62 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 tab system using the tab system you can generate multiple analysis from the same raw data. For example: you can generate a periodogram analysis using the pim and another one using the tat. You can ...

  • Page 63: Report

    Copyright © 2013, condor instruments ltda. 63 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 report here it is possi ble to include wearer information’s and doctor conclusions. All those information will be included in the pdf report file. Report page used to insert some relevant informati...

  • Page 64: Report Settings

    Copyright © 2013, condor instruments ltda. 64 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 report settings here it is possible to configure some report parameters, such as insert a logo and footer. Header and footer field used to put a logo at the header and a message at the footer (e.G....

  • Page 65

    Copyright © 2013, condor instruments ltda. 65 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 load load the default logo image and the footer text. Save save the logo image and the footer text as default. Ok button used only to close the report settings window. Report options field used to ...

  • Page 66: Making A Report

    Copyright © 2013, condor instruments ltda. 66 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 making a report 1. Extract or load the data to be analyzed. 2. Go to the sleep scoring page and verify the data. 3. If necessary, all the areas (off wrist, sleep, rest) can be edited and reassigned...

  • Page 67

    Copyright © 2013, condor instruments ltda. 67 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 5. On the report menu, insert all relevant data about the subject. 6. On the report settings page, select the options that will be shown in the report. 7. Click on the print report button and selec...

  • Page 68: Rebooting Acttrust

    Copyright © 2013, condor instruments ltda. 68 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 rebooting acttrust 1. In the control menu, navigate to the support menu. 2. Press the reset button and wait. 1 2.

  • Page 69

    Copyright © 2013, condor instruments ltda. 69 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 generating a report of the acttrust 1. Navigate to the support menu. 2. Press the make report button and wait for the report to be generated and displayed in the text box. 3. Press the save report ...

  • Page 70: Important Tips

    Copyright © 2013, condor instruments ltda. 70 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 important tips some useful tips that may facilitate the actstudio use. Calculate analysis you can calculate all the analysis functions at once by clicking the calculate analysis button in the main ...

  • Page 71: Export Graphs

    Copyright © 2013, condor instruments ltda. 71 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 export graphs every graph can be saved as image (png, jpeg or bmp), by right-clicking the mouse on it and selecting the save as image option. Export data tables every data table can be saved as a c...

  • Page 72: Zoom On Graphs

    Copyright © 2013, condor instruments ltda. 72 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 zoom on graphs you can zoom in almost any graphs. Just hold the shift key: and perform zoom in and zoom out using the mouse scroll. Zoom in: zoom out: scroll bar hidden on os x if you are using som...

  • Page 73: General Settings

    Copyright © 2013, condor instruments ltda. 73 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 general settings you can manage the actstudio general settings using the "general settings" menu: you can save all settings, import settings (ini file format), export settings or reset all settings...

  • Page 74: Copying The Database

    Copyright © 2013, condor instruments ltda. 74 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 copying the database the actstudio is portable and it means you can run it without the need of installation (actually, you can run it from a pen drive), but the database is stored on your computer,...

  • Page 75: Selected Log Information

    Copyright © 2013, condor instruments ltda. 75 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 selected log information when you select a database log from the log list page, you will see the following log information in the right upper corner: this information is related to the log that you...

  • Page 76

    Copyright © 2013, condor instruments ltda. 76 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 the following page will be shown: in the "actstudio version log" page you can see the version number, the date that the version was released and all changes that were included. Eset endpoint antivi...

  • Page 77

    Copyright © 2013, condor instruments ltda. 77 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000

  • Page 78: Troubleshooting

    Copyright © 2013, condor instruments ltda. 78 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 troubleshooting most problems with the acttrust can be resolved quickly following the guidelines in this chapter. If the problem persists, please contact condor instruments personnel to receive new...

  • Page 79

    Copyright © 2013, condor instruments ltda. 79 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 known location. After saving the report, try restarting the device. If the problem persists, please contact condor instruments personnel to receive new guidelines. If contacting by email, please at...

  • Page 80: Specifications

    Copyright © 2013, condor instruments ltda. 80 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 specifications general specifications weight without band 19g weight with band 38g dimensions 47mm x 31mm x 12mm ambient conditions operation temperature: 0 °c a 60 °c (32 °f a 140 °f) storage and ...

  • Page 81: Applicable Standards

    Copyright © 2013, condor instruments ltda. 81 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 notes: the manufacturer reserves the right to change these specifications without notice. Applicable standards temperature sensors precision +/-0.5ºc (20°c to 40°c)/ 1°c for other values operating ...

  • Page 82: Immunity And Emission

    Copyright © 2013, condor instruments ltda. 82 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 manufacturer’s declaration - electromagnetic immunity and emission the medical electrical equipment needs special precautions regarding electromagnetic compatibility (emc) and needs to be installed...

  • Page 83

    Copyright © 2013, condor instruments ltda. 83 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 manufacturer’s declaration – electromagnetic immunity ii the product is suitable for use in a specific electromagnetic environment. The customer and/or the user of the product should assure that it...

  • Page 84

    Copyright © 2013, condor instruments ltda. 84 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 environmental information this device should be disposed in accordance with the rules and regulations of the country in which the disposal takes place. For more information about the disposal of pr...

  • Page 85: Symbols

    Copyright © 2013, condor instruments ltda. 85 av. Brigadeiro luis antonio, 551, cj 124 - cep:01318-000 symbols general attention warning read the operation instructions recyclable material weee – waste eletrical and eletronic equipment dispose at appropriate site temperature limits applied part type...