Conel CGU 04i User Manual

Manual is about: GPRS modem

Summary of CGU 04i

  • Page 1

    Gprs modem cgu 04i user´s guide declared system iso 9001:2009.

  • Page 2: Contents

    Contents 2 contents 1. Safety instructions ...................................................................................................... 4 2. Description of the communication module cgu 04i ......................................... 5 2.1. General ...............................................

  • Page 3: Symbols Used

    Contents 3 5.1.1 analogue input ......................................................................................................... 47 5.1.2 binary output ............................................................................................................ 47 5.1.3 i/o signals inside cg...

  • Page 4: 1. Safety Instructions

    Safety instructions 4 1. Safety instructions please observe the following safety instructions: • the communication module must be used in compliance with all applicable international and national laws and in compliance with any special restrictions regulating the utilization of the communication mod...

  • Page 5

    Cgu 04i description 5 2. Description of the communication module cgu 04i 2.1. General gsm/gprs communication module cgu 04i is a wireless data transmission device. The communication module is one of the basic elements of agnes gprs system. The system agnes characteristics are described in reference ...

  • Page 6

    Cgu 04i description 6 2.4. Description of cgu 04i components 2.4.1 gsm module cinterion module is used for gsm network wireless communication. It is integrated into printed circuit board. Fme antenna connector is accessible from the back panel. Release sim card reader is located on the front panel. ...

  • Page 7

    Cgu 04i description 7 the microprocessor further manages numerous functions of servicing, diagnostic and installation purposes. Data transfer statistics, separate port communications, power blackouts, voltage of the reserve supply, cgu 04i temperature and other important information – everything is ...

  • Page 8

    Cgu 04i description 8 2.4.5 user interface protocols there are numerous industrial protocols implemented on the user interface: • arnep ui • profibus • mbus • modbus • at modem • sauter • iwka • sbus • radom • rds conel new protocols, not supported by the communication module yet, can be implemented...

  • Page 9

    Cgu 04i description 9 2.5. Technical parameters gsm module cinterion complies with standards power safety emc radio parameters Čsnen 60 950:2000 Čsn etsi en 301 489-1:v1.2.1; -7:v1.1.1 Čsn en 55022 3gpp ts51.010-1,v5.5.0 Čsn etsi en 301 511,v7.0.1 frequency bands egsm900, gsm1800 and gsm1900 (gsm ph...

  • Page 10

    Cgu 04i description 10 2.6. Module status indication there are two led indicators on the front panel informing on its status. Colour description description green pwr flashes once a sec………..….Proper function lights permanently……….…...Fault off…………………………...….No dc supply or sleep mode red gprs lights...

  • Page 11

    Cgu 04i description 11 2.7. User interfaces (connectors) there are rj45 (port1 and port2), rj12 (pwr) and fme (ant) connectors located on the back panel. The two port1 and port2 (optional) connectors are for user interfaces. The fourth pwr connector is for supply adapter connection. Antenna is conne...

  • Page 12

    Cgu 04i description 12 2.7.1 port1 (port2) connector - rs232 panel socket rj45 (rs232 – dce - data communication equipment). Pin number signal mark description data flow direction 1 rts request to send input 2 cts clear to send output 3 dtr data terminal ready input 4 dsr data set ready – connected ...

  • Page 13

    Cgu 04i description 13 example of the pc connection to the cgu 04i: z cable kd2 is connected to serial port pc (example com1) example of the rs232 equipment connection to the cgu 04i (possibility to use all rs232 ports): cable kd-2 modem cgu 04i port1 port2 pwr cable kd-2 modem cgu 04i port1 port2 p...

  • Page 14

    Cgu 04i description 14 2.7.2 port2 connectors on demand of the client it is possible mounting second interface. The second interface may be rs232, rs422, rs485, m-busd or cnt. If port2 isn't mounted, connector will not active. 2.7.3 connector port2 - rs485 panel socket rj45 pin number signal mark de...

  • Page 15

    Cgu 04i description 15 circuit example of the equipment with a modem with data length less than 10 m: circuit example of the equipment with a modem with data length more than 10 m: at rs485 data cable more than 10m it is need to use overvoltage protection on the modem side! Pin 1 – sgdn pin 2 – sgnd...

  • Page 16

    Cgu 04i description 16 2.7.4 connector port2 - rs422 pin number signal mark description data direction 1 gnd signal and supply ground 2 gnd signal and supply ground 3 rxd- receive data (-) input/output 4 rxd+ receive data (+) input/output 5 txd- transmit data (-) input/output 6 txd+ transmit data (+...

  • Page 17

    Cgu 04i description 17 circuit example of the equipment with a modem with data length more than 10 m: at rs422 data cable more than 10m it is need to use overvoltage protection on the modem side! 1y 2y dc meter sgnd txd (-) txd (+) rxd (-) rxd (+) modem cgu 04i pin 1 – sgnd pin 2 – sgnd pin 3 – rxd ...

  • Page 18

    Cgu 04i description 18 2.7.4.1 connector port2 – mbusd panel socket rj45 pin number signal mark description direction 1 sgnd signal and supply ground 2 sgnd signal and supply ground 3 txrx- mbus b (-) input/output 4 txrx+ mbus a (+) input/output 5 txrx- mbus b (-) input/output 6 txrx+ mbus a (+) inp...

  • Page 19

    Cgu 04i description 19 circuit example of the equipment with a modem with data length more than 10 m: if an m-bus data cable more than 10m it is need to use overvoltage protection on the router side! Dc meter sgnd mbus (-) mbus (+) meter sgnd mbus (-) mbus (+) modem cgu 04i pin 1 – sgnd pin 2 – sgnd...

  • Page 20

    Cgu 04i description 20 2.7.4.2 connector port2 – cnt panel socket rj45 pin number signal mark description direction 1 bin0/cnt0 binary input/counter input input 2 bin1/cnt1 binary input/counter input input 3 bin2 binary input input 4 bin3 binary input input 5 gnd signal ground 6 out0 binary output o...

  • Page 21

    Cgu 04i description 21 2.7.5 cio connector panel socket rj45 pin number signal mark description direction 1 i/o 5 input/output – analogue or binary input or binary output (open collector) input/output 2 i/o 4 input/output – analogue or binary input or binary output (open collector) input/output 3 i/...

  • Page 22

    Cgu 04i description 22 circuit example: the cio 2 modules are connected by the help of kd-51 cable (cable 1:1). The connector k1 is input, k2 output to other cio 2 module. By serial modems connection the addresses are automatically assigned. In the direction from modem the addresses raises uplink: 1...

  • Page 23

    Cgu 04i description 23 2.7.6 pwr supply connector panel socket rj12 pin number signal mark description direction 1 +un positive pole of dc supply voltage (10 to 30 v) 2 pwrsv output open collector (power save) see cio description output 3 inac network supply presence check. Range 0 – 16 v input 4 +u...

  • Page 24

    Cgu 04i description 24 dc supply with backup battery with present supply monitoring dc supply with backup battery without present supply monitoring + dc + modem cgu 04i pin 1 – +un pin 2 – nc pin 3 – inac pin 4 – +un pin 5 – gnd pin 6 – gnd + dc + modem cgu 04i pin 1 – +un pin 2 – nc pin 3 – inac pi...

  • Page 25

    Cgu 04i description 25 2.8. Antenna connection antenna is connected to cgu 04i by fme connector on the back panel. 2.9. Technical specifications of port 2 • for product expansion port m-busd expansion port m-busd power supply voltage +10 .. +30 v supply power max. 4 w environment operating temperatu...

  • Page 26

    Cgu 04i description 26 • for product expansion port rs485 – rs422 expansion port rs485-422 rs485 rs422 power supply external +10 .. +30 v internal .... Supply power max. 1 w supply current max. 4 ma environment operating temperature -20 .. +55 c storage temperature -20 .. +85 c standards emission en...

  • Page 27

    Cgu 04i description 27 the jumper circuitry for rs485 the jumper circuitry for rs422 • for product expansion port rs232 expansion port rs232 power supply internal .... Environment operating temperature -20 .. +55 c storage temperature -20 .. +85 c standards emission en 55022/b immunity ets 300 342 s...

  • Page 28

    Cgu 04i description 28 2.10. Cgu 04i settings configuration and service sw radwin is designed for the module setup (reference [3] ). The software is created for ms windows 95/98/me/2000/xp platforms. Service cable is designed for cgu 04i connection. After service cable (data cable kd-2 and jump serv...

  • Page 29

    Cgu 04i description 29 2.12. Standard accessories 1. Rj12 supply connector for supply voltage cable. 2. Three rj45 connectors for data cables and cio connection. 3. Compliance certificate. 4. Complaint procedure. 5. Warranty. 6. User manual 2.13. Additional accessories 1. Supply adapter 2. Ao-agsm-f...

  • Page 30

    Cgu 04i description 30 2.14. Assembly procedure cgu 04i module is designed as a standard for: 1. Assembly to a panel using the through holes. Through hole for assembly.

  • Page 31

    Cgu 04i description 31 2. Din 35 mm rail assembly using plastic grips. 3. To be put on a worktop.

  • Page 32

    Cgu 04i description 32 2.15. Mechanical external dimensions and mounting recommendations for the majority of applications with a built-in modem in a switch board it is possible to recognize two sorts of environments : z nopublic and industry environment of low voltage with high interference, z publi...

  • Page 33

    Cgu 04i description 33 z for single cables we recommend to bind the bunch according to the following picture, for this use we recommend: • length of the bunch (combination of power supply and data cables) can be maximum 1,5 m, if length of data cables exceeds 1,5 m or in the event of, the cable lead...

  • Page 34

    Cgu 04i description 34 z for correct function of the modem we recommend to use in switch - board earth- bonding distribution frame for grounding of power supply of modem, data cables and antenna, z the circuit diagram of the modem is on the following pictures..

  • Page 35

    Cgu 04i description 35 2.16. Product marking trade name type name antenna connector supply interfaces other cgu 04i cgu-04i fme 10 – 30 v 1x rs232 cio, class 10 2.17. Port2 marking trade name type name supply other expansion port rs232 xc-232 internal from module cgu 04i expansion port rs485-rs422 x...

  • Page 36

    Cgu 04i description 36 2.19. Expansion ports labels.

  • Page 37

    Cgu 04i description 37 2.20. Basic parameters description for monitoring of status, configuration and administration of the modem is radwin program [3]. In right under main menu is function list where is possible choice configuration (ctrl + f1). Next table describes parameters of the tap basic. Por...

  • Page 38

    Cgu 04i description 38 parameter name set value range parameter description interface address x --- interface address information on particular port. Gprs – network x address range auto/256 up to 8182 by this parameter is possible to set maximal usable interface addresses range in particular network...

  • Page 39

    Cgu 04i description 39 parameter name set value range parameter description gprs – enable duplicate registration yes/no when the station is local dns server, then this parameter enable logging of the modem with dynamical ip address to network. The modem changes own ip address after some time and the...

  • Page 40

    Cgu 04i description 40 parameter name set value range parameter description received sms sent to com1/com2/ com3/nowhere if the modem receive new sms message than this sms message will be send to defined modem port by this parameter. Sms format 7-bit/ 8-bit by this parameter is possible to set forma...

  • Page 41

    Cgu 04i description 41 parameter name set value range parameter description preferred gsm operator x 0 up to 9999 by this parameter it is possible define the gsm operator on which the modem will try record. Send m-bus short status yes/no when m-bus short start and end is send information to the glob...

  • Page 42

    Cgu 04i description 42 3. Quality of the gprs signal the agnes system works with the aid of the gsm network. The agnes stations contain gsm-gprs modules, which are on the radio channel connected to a certain gsm cell. Its signal can be evaluated with the aid of this function. The function is used fi...

  • Page 43

    Cgu 04i description 43 3.4. Method of signal measurements run radwin, function “gprs receive signal strength measuring”. Answer is information about serving and remaining cells. Output is from at commands at^moni and at^monp from gprs module. 3.5. At^moni command meaning serving cell: item descripti...

  • Page 44

    Cgu 04i description 44 3.6. At^monp command meaning item description chann arfcn (absolute frequency channel number) of the bcch carrier rs rssi value 0 . 63 (rssi = received signal strength indication) dbm receiving level in dbm plmn plmn id code bcc base station colour code c1 coefficient for base...

  • Page 45: 4. Expansion Port Mounting

    Expansion ports mounting 45 4. Expansion port mounting attention! Expansion port include when the modem cgu 04i is switch off. After unscrewed two screws (position 8) on box bottom part (position 3) and carried out box top part (position 2) the expansion port port2 (position 6) connect to connector ...

  • Page 46

    Expansion ports mounting 46 parts list and description part description number 1 modem cgu 04i motherboard 1 2 cgu 04i box top part 1 3 cgu 04i box bottom part 1 4 cgu 04i rear head 1 5 cgu 04i front head 1 6 expansion port 1 7 distant columns for expansion port port2 mounting to motherboard 3 8 scr...

  • Page 47

    Cio description 47 5. Cio – analogue inputs and binary outputs cgu 04i module is equipped with user interface cio for analogue signal reception and processing and control (settings) of binary signals. User is provided with 5 adjustable inputs/outputs located on cio connector at the front panel. More...

  • Page 48

    Cio description 48 5.1.4 i/o signals parameters signal name measuring range [v] resolution [bit] sampling [ms] average from samples hysteresis control level i/o1-5 0 to 5 10 100 optional 1 – 128 optional 0 – 255 optional 5.2. Measuring other cgu 04i signals 5.2.1 measuring the supply voltage another...

  • Page 49

    Cio description 49 5.2.3 measuring dsr output signal level dsr signals on separate user interfaces are output signals from cgu 04i viewpoint. They are not controlled form the inside. Individual signals are linked through 330 ohm resistors. By placing 100 ohm ground resistor on dsr output the voltage...

  • Page 50

    Cio description 50 name type description cio ani analogue input analogue differential input for small voltage, current and resistance measuring it includes differential amplifier with adjustable power 1 to 10000. Exact current source 0.1 to 3 ma can be used to measure resistance. Configuration of th...

  • Page 51: 6. References

    References and links 51 6. References [1] conel s.R.O.: application cgu server , 2004 [2] conel s.R.O.: arnep protocol description , 2007 [3] conel s.R.O.: radwin programme for control agnes , 2008 [4] conel s.R.O.: cio 2 users guide , 2008 [5] conel s.R.O.: gprs modems – application guide , 2008 7....

  • Page 52

    Product disposal 52 8. Product disposal information the weee (waste electrical and electronic equipment: 2002/96/ec) directive has been introduced to ensure that electrical/electronic products are recycled using the best available recovery techniques to minimise the impact on the environment. This p...

  • Page 53

    Complaints procedure 53 9. Complaints procedure dear customer, the product you have purchased had passed manufacturer’s tests and its functions had been checked by our technician before sale. In case any defect shows up during the guarantee period that prevents normal use we ask you to follow the co...

  • Page 54

    Complaints procedure 54 1. After 12 months since the replaced product was taken over by the customer. 2. On the date when the original guarantee period (subject of the complaint) would have expired should it not have been replaced, whichever comes first. 3. The claim is deemed unsubstantiated when t...

  • Page 55

    Warranty 55 10. Warranty device type serial number guarantee period (months) vendor date of purchase seal of the vendor.

  • Page 56

    Warranty 56 1 2 3 4 5 date of complaint registration complaint protocol number date of reception of the device in repair shop date of finished repair number of repair sheet warranty repair yes – no yes – no yes – no yes – no yes – no new serial number of the device (imei) notes seal of the repair sh...