Connerton Co RLRB-A Installation And Operating Insctructions

Summary of RLRB-A

  • Page 1

    Fine cooking equipment for over 70 years 1. Preparation for installation: z223.1 installation must be made by a licensed plumber. Safe and satisfactory operation of the broiler depends, to a great extent, upon it’s proper installation. It should be installed in accordance with the national fuel gas ...

  • Page 2

    2. Clearances and ventilation: keep equipment area free and clear from combustibles. 3. Gas piping: please note: air vent on regulator can plug with grease, thereby shutting gas supply off. Install regulator in drip-free area. Ansi z21.69 ansi z21.41 important: check all gas connections for leaks, u...

  • Page 3

    Rlrb-a budget series char broilers 1. 65-400-xx body 9. 00-675-00 air shutter 2. 60-475-xx firebox 10. 60-125-00 radiant 3. 60-425-xx front panel 11. 60-350-00 pilot w/tubing 4. 65-450-xx grease pan 12. 60-300-xx gas manifold 5. 60-100-02 waffle grate 13. 00-225-00 pilot valve 6. 60-100-01 top grate...

  • Page 4: Troubleshooting Guide

    Small/no burner flame regulator failure unplug regulator vent hole or replace regulator. Plugged orifice hood unplug hole or replace orifice. Plugged burner port unplug burner port(s). Small/no pilot flame pilot valve setting adjust flame height. Plugged pilot tip unplug pilot ports. Yellow burner f...