Conrad GX103+GPS Operating Instructions Manual

Summary of GX103+GPS

  • Page 1

    Operating instructions gsm-gps tracker with alarm function „gx103+gps“ item no. 66 24 93 version 07/12.

  • Page 2: Table of Contents

    2 table of contents page 1. Introduction ................................................................................................................................................................................................ 3 2. Intended use ...................................................

  • Page 3: 1. Introduction

    3 page 13. Position determination ............................................................................................................................................................................. 27 a) general gps localisation (command “gps”) ................................................

  • Page 4: 2. Intended Use

    4 2. Intended use the product serves to monitor your property. To secure your property, sensors like vibration, motion detectors (pir), microphone and a gps receiver are available. The integrated gps receiver serves precise determination of the position, geofence monitoring and tracking of movements...

  • Page 5: 5. Safety Information

    5 5. Safety information the guarantee/warranty will expire if damage is incurred resulting from non-compliance with these operating instructions. We do not assume liability for any consequential damage. Nor do we assume any liability for damage to property or personal injury caused by improper use o...

  • Page 6: 7. General Descriptions

    6 7. General descriptions this product is to be used to monitor the customer’s property. In case of alarm, its primary task is in informing the customer of it as quickly as possible by text message. Scaring off by an alarm sound is an addition option that must be configured. Vibrations can be monito...

  • Page 7

    7 gsm led (5): this led shows the current gsm status. For this, the led has the following presentation options: • led is lit green = searching for gsm network • led flashes green (every 1 s) = device registered at the gsm network • led flashes green (every 1/2 s) = call / phone connection • led flas...

  • Page 8

    8 left button (6): this button switches the alarm mode of the product. The change is triggered only after pushing and holding the button for a few seconds. Depending on configuration (see function description on the command “countdown”), a countdown signal is generated upon activation to give the us...

  • Page 9

    9 b) product status and mode the product has the following modes: “alarm enable”: this mode is entered by the text message command “alarm enable”, pushing and holding the left button and, depending on configuration, e.G. Via a call. Whether or not the alarm is active can only be seen by a status tex...

  • Page 10

    10 e) notes on the electrical connection • the external cables must be kept as short as possible and remaining line lengths must not be coiled. • too-strong temperature fluctuations may lead to temporary impairment and require manual reset in extreme cases. • the product is not intended for the “saf...

  • Page 11

    11 c) sim card insertion • the sim card with the pin number “1513” must be inserted in the device as shown in the following. • when the sim card is inserted, the product is still switched off. To switch it on, push the “on/off” button (7) for a few seconds until the gsm led lights up. First, the gsm...

  • Page 12

    12 10. Configuration via text message a) general information to receive the full functional scope of the product, it must be configured first. The entire configuration is performed by simple text message commands you send to the device (the phone number of the sim card in the device) from your mobil...

  • Page 13

    13 a parameter may be the following: list: the customer may choose a parameter from a pre-defined list, e.G.: de, en, lh, hl, lhl,… writing: , number: an integer without decimal digits, optionally with prefix, e.G.: 5 = time [sec.] (set in1 lh 5 #1513) writing: time = xxx to xxx, xxx = …. Examples: ...

  • Page 14: 11. Functional Descriptions

    14 11. Functional descriptions in the following examples, it is assumed that the pin of the sim card in the device is “1513”. A) general configuration commands 1. Changing the pin code (command “pin”) to secure the product from unauthorised access, the standard pin “1513” may be set to any other val...

  • Page 15

    15 3. Setting the language (command “language”) this command sets the product langauge. Set language #1513 example: set language de #1513 this command is needed to reset to german: reset language #1513 there is no test command for this command. 4. Setting time and date (command “time”) the product o...

  • Page 16

    16 5. Administration of phone book (command “tel”) up to 6 phone numbers can be programmed into the device. In case of alarm, a notification text message is sent to each of these phone numbers. Additionally, only these phone numbers are accepted for the incall function. If the same number is in the ...

  • Page 17

    17 deleting the phone numbers saved to delete a phone number, you need the following commands: example: deleting the 1st and 3rd number reset tel1 #1513 reset tel3 #1513 to delete all phone numbers: reset telall #1513 after sending the command “reset tel....”, you will receive a text message answer....

  • Page 18

    18 7. Speaker events (command “soundinfo”) during the setup phase, it may be of benefit to hear what the product does right now. In may places of the firmware, sound outputs are stored that indicate an event. By default, these sounds are deactivated so that the module will not give itself away durin...

  • Page 19

    19 9. Time setting alarm activation/deactivation (command “countdown”) the alarm function is also changed, e.G. Directly at the device using the left button. However, you are in sensor range for the condition change (“alarm enable” to “alarm disable”) when the button is used for the change. To give ...

  • Page 20

    20 b) in- and outputs this is an autonomously working alarm reporting device. Wrong settings or connections can cause undesired txt messages to be sent and possibly high costs! Never enter the phone number that belongs to the sim card that is inserted in the module! Also never enter any phone number...

  • Page 21

    21 2. Setting support (command “diagnose”) for the sensors to be easier to configure, this command was introduced. After activation, this function controls the leds of the three buttons “1”, “2” and “3” in the “alarm disable” mode, as well as the speaker. When a sensor recognises something in its cu...

  • Page 22

    22 the following functions are possible: • function: phone number you may assign a phone number to either of the three buttons. If you want to assign the phone number 015112233… to button “1”, the command is: set key1 tel +4915112233… #1513 • function: switching sensor activation you can use the but...

  • Page 23

    23 c) additional functions 1. Recall in case of alarm (function “recall”) when an event triggers an alarm in the “alarm enable” mode, an alarm text message is sent to all phone numbers in the phone book. This makes it possible to call back another phone number. This is configured with the following ...

  • Page 24

    24 the “incall” event can trigger the following actions: return gps/gpsmap position: to save costs, use the “incall” function to return the current gps position to the calling number. Set incall [all] #1513 here, either the gps coordinates or a link are returned to the caller by an sms message after...

  • Page 25

    25 3. Lifesign (function “alive”) for some providers, the sim card is deactivated if no costs have been incurred within a specific period (e.G. 3 months). To keep the card active, you can have a status text message sent regularly with this function. Alternatively, it may be of interest to regularly ...

  • Page 26: 12. Configure Expansions

    26 12. Configure expansions this lateral 2.5 mm jack socket serves to expand the product with various accessories. There are some items to be observed: • whether and which accessories are offered for the product can only be found out via the website for the product at www.Conrad.Com in the accessori...

  • Page 27: 13. Position Determination

    27 13. Position determination the gps receiver can be used to determine the current gps position. Furthermore, the user is able to be informed when the product leaves a pre-defined (permitted) area. All functions in connection with position determination are explained below. Please note the followin...

  • Page 28

    28 b) submission of a web link with gps position (command “gpsmap”) if you have a mobile phone with internet connection, you may also have the current gps coordinates displayed via a web link to a settable map material provider. This can directly display the current position. The command for this fu...

  • Page 29

    29 d) activate position tracking (command “track”) the term “tracking” means regular saving of the current position, including time stamp, in the internal memory. The number of saved points depends on the firmware version; the current number can only be determined with the test command. At a later t...

  • Page 30

    30 deleting data: to delete all data and release the memory for new recordings, the follwong command is used: reset trackdata #1513 e) programming the gps zone (command “gpszone”) the product may be used for zone monitoring. After programming of the permitted zone (max. 10) and after activation of t...

  • Page 31

    31 the following message is returned for confirmation: gx103gps 1.08 gps zone: 1/1 latitude: 49.549680n to 49.537480n longitude: 011.924780e – 01.957910e observe that every command “set gpszone” will add a new zone. If the storage limit is reached, an error message will be returned. Deleting all sav...

  • Page 32: 14. System Functions

    32 14. System functions this chapter describes technically sophisticated functions. The default settings are already set for most application areas. Therefore, we recommend only adjusting these parameters in the respective application cases. If the product has any malfunctions, first reset the defau...

  • Page 33: 15. Factory Settings

    33 15. Factory settings the device can be manually reset to the factory settings when: • the device no longer reacts • the pin number in the device was forgotten • the product does not behave as configured • the configuration is set to impossible values proceed as follows: • the device is switched o...

  • Page 34: 18. Technical Data

    34 18. Technical data a) gsm-gps-tracker charge cycle ................................................... Approx. 3h (after complete battery discharge) rechargeable battery...................................... Li-po, 1100 mah, 3.7 v/dc gsm module ................................................... ...

  • Page 35

    35.

  • Page 36: Http://www.Conrad.Com

    Legal notice these operating instructions are a publication by conrad electronic se, klaus-conrad-str. 1, d-92240 hirschau (www.Conrad.Com). All rights including translation reserved. Reproduction by any method, e.G. Photocopy, microfilming, or the capture in electronic data processing systems requi...