D&b Audiotechnik D12 Hardware Manual

Other manuals for D12: Hardware Manual, Hardware Manual

Summary of D12

  • Page 1

    D12 amplifier hardware manual (2.0e).

  • Page 2

    References in the manual warning! This refers to a potentially dangerous situation which may lead to personal injury. Caution! This refers to a potentially dangerous situation which may lead to personal injury. Important! This refers to a situation which may cause the equipment to malfunction. Note:...

  • Page 3

    Contents 1. Safety precautions...........................................................5 1.1. Information regarding use of the d12 amplifier...............................5 2. Introduction......................................................................7 2.1. Scope of supply.....................

  • Page 4

    7.2. Technical drawings..................................................................................28 8. Eu declaration of conformity (ce symbol)....................29 8.1. Eu conformity d12..................................................................................29 index.................

  • Page 5

    1. Safety precautions before you use our products, read the manual carefully and observe all the safety precautions. They will protect you and help to avoid equipment failures. Keep this manual in a safe place so that it is available for future reference. If you supply d&b products, please draw the ...

  • Page 6

    Warning! All other work should be performed by trained service staff, especially in the following cases: - mains power cable, socket or plug has been damaged - objects or liquids have entered the unit - the unit is not operating normally - the unit was dropped or the housing is damaged caution! The ...

  • Page 7

    2. Introduction this manual describes the facilities and functions of the hardware of the d&b d12 amplifier. A detailed description of the d12 software and remote control is given in the d12 amplifier software manual, which is also provided with the d12 amplifier. A number of publications with suppl...

  • Page 8

    3. D12 amplifier 3.1. D12 based systems fig. 1: d12 amplifier the d&b d12 amplifier is a two channel power amplifier that incorporates digital signal processors (dsp) providing loudspeaker specific controller functions. It is designed for use with all current d&b loudspeakers, and a linear mode is a...

  • Page 9

    3.3. Digital signal processing the digital signal processing provides loudspeaker specific set ups that are selected using the front panel controls. These set ups include all loudspeaker equalization and protection functions. A 4-band parametric equalizer is incorporated in each channel to provide o...

  • Page 10

    3.4. D12 power amplifiers the two power amplifiers fitted to the d12 can deliver 2 x 750 w continuous sine wave power into an 8 ohms load, increasing to 2 x 1200 w continuous sine wave power into a 4 ohms load. These maximum output ratings measured with sine wave are valid for minutes only until the...

  • Page 11

    3.6. Power supply the d12 utilizes an autosensing switch mode power supply for mains voltages 115/230 v, 50 - 60 hz (optional 100/200 v) and overvoltage protection. Where voltages outside of this range are present, a self-resetting protective circuit responds quickly to isolate the internal amplifie...

  • Page 12

    3.6.1. Inrush current limiter a mains inrush current limiter provides a "soft start" and enables several d12s to be powered up at the same time without overloading the mains power supply. The maximum current drawn during the power up phase is dependant on the mains voltage, however nominal values ar...

  • Page 13

    4. Controls and indicators d12 level push menu mute power a b on off ovl gr isp ovl gr isp [1] [3] [2] [4] [5][6][7] fig. 3: d12 controls and indicators 4.1. Controls 4.1.1. Mains power switch [1] power on off [1] fig. 4: d12 mains power switch the on/off rotary switch is located on the right hand s...

  • Page 14

    - regular short flashes (1:8 duty cycle): ⇒ standby: in standby mode the loudspeaker outputs are electronically isolated and the d12 idles, drawing minimal mains power. Only the most essential functions are provided. Display and network remain functional, the display illumination is switched off aft...

  • Page 15

    4.2. Indicators 4.2.1. Lc display [4] ovl gr isp ovl gr isp [4] [5][6][7] [5][6][7] ch a ch b fig. 6: d12 indicators in detail serves as a user interface and display for all configuration settings and status information. The display is illuminated and can be set to "on/off/timeout 10s." a detailed d...

  • Page 16

    4.2.4. Ovl led (a/b) - overload (red) [7]: - illuminates depending on the input signal ⇒ overload: either the input signal level is too high or the d12 is trying to deliver too high an output current. If in doubt reduce the input gain at the d12 level control. If the error message disappears, the ou...

  • Page 17

    5. Connections out a out b input link ch b analog digital aes/ebu ch a analog service remote voltage see label ~ 50/60 hz 3500 w max. Caution risk o f elect ric shock do not open www.Dbaudio.Com mains supply risk of fire - replace fuse as marked t10a h / 250 v fuse t10a h / 250 v fuse made in german...

  • Page 18

    5.1.3. Remote [10] 1......8 1......8 pin 1 n.C. Pin 2 n.C. Pin 3 n.C. Pin 4 can_h pin 5 can_l pin 6 n.C. Pin 7 rib data pin 8 rib data shield can ground fig. 9: pin assignment for remote control (rj45) the d12 is fitted with a 2-wire serial remote control interface, (2 x rj 45) carrying both the rib...

  • Page 19

    5.1.5. Connector panel (i/o panel) out a out b input link ch b analog digital aes/ebu ch a analog fig. 11: d12 i/o panel all signal input and output connections are located on the rear i/o panel. These include analog and digital (aes/ebu) signal inputs, link outputs for each channel. Loudspeaker out...

  • Page 20

    5.1.8.1. Dual channel mode out a sensedrive when sub selected out b sensedrive when sub selected amp b amp a input a input b fig. 15: d12 input/output routing dual channel mode with standard input routing the "dual channel mode" is dedicated to all d&b passive systems and max/max12 in passive mode. ...

  • Page 21

    5.2. Pin assignments/pin equivalents the passive full range/top systems and passive subwoofers use pins 1 and 2 of the ep5 connector (1+ and 1– of the nl4 connector). Active driven subwoofers use pins 3/4 and pin 5 of the ep5 connectors (2+ and 2– of the nl4 connector). Ep5 nl4 top+ 1 1+ top– 2 1– s...

  • Page 22

    5.3. D12 i/o modes (default input routing) lo + lo – hi + hi – d12 output modes (displayed with default input routing) dual channel mode mix top/sub mode ou t a sensedrive when sub sel e ct ed ou t b sensedrive when sub sel e ct ed am p b am p a 2- way- ac tive mode input a input b input a 1 2 3 4 5...

  • Page 23

    6. Installation and operation 6.1. Installation d12 amplifier enclosures are designed to fit a standard 19" equipment rack or cabinet. The front panel vent slot serves as a useful handle for lifting and moving amplifiers in and out of racks. When specifying a rack, be sure to allow extra depth (10 c...

  • Page 24

    6.2. Operation 6.2.1. Power consumption and power loss the power required from the mains supply and the waste heat produced by the amplifiers power loss vary depending on the load impedance and the signal levels and characteristics (e.G. Speech, music). In practice, the theoretical peak power consum...

  • Page 25

    6.2.2. Operating conditions the following diagram shows the thermal operating range within which the technical data will be maintained. The operation beyond this range is possible for a short time and for thermal reasons this will trigger the amplifier protection circuit into thermal overload. 0 5 1...

  • Page 26

    7. Technical documentation 7.1. Technical specifications displays isp a/b...................................................................Input signal present indicator (green) gr a/b.........................................................................Gain reduction indicator (yellow) ovl a/b....

  • Page 27

    Protection circuits mains inrush current limiter..................................................................5 a rms at 230 v ........................................................................................................10 a rms at 115/100 v speaker switch on delay.......................

  • Page 28

    7.2. Technical drawings d12 level push menu mute power a b on off ovl gr isp ovl gr isp fig. 21: d12 front view fig. 22: d12 rear view 348 [13.70"] 328 [12.91"] 483 [19.00"] 443 [17.44"] 338 [13.31"] 132 [5.20"] 5 [0.20"] d12 level push menu mute power a b on off ovl gr isp ovl gr isp fig. 23: d12 e...

  • Page 29

    8. Eu declaration of conformity (ce symbol) 8.1. Eu conformity d12 this declaration applies to the d12 amplifier manufactured by d&b audiotechnik ag consisting of the amplifier unit. - d12, z2600.000/001 - d12, z2600.300/301 all products of type d12 starting from variant z2600.000 are included, prov...

  • Page 30

    Index figures used in the manual fig.# titel page fig. 1: d12 amplifier.....................................................................8 fig. 2: d12 amplifier block diagram........................................8 fig. 3: d12 controls and indicators.......................................13 fig....

  • Page 32

    D2012.E.02, 08/2004 © d&b audiotechnik ag d&b audiotechnik ag, eugen-adolff-str. 134, d-71522 backnang, germany, phone +49-7191-9669-0, fax +49-7191-95 00 00 _______.