Summary of M6

  • Page 1

    M m6 manual 1.1 en.

  • Page 2

    S y m b o l s o n t h e p r o d u c t p l e a s e r e f e r t o t h e i n f o r m a t i o n i n t h e m a n u a l . W a r n i n g ! D a n g e r o u s v o l t a g e ! General information m6 manual version: 1.1 en, 09/2017, d2605.En .01 copyright © 2017 by d&b audiotechnik gmbh; all rights reserved. K...

  • Page 3

    1. Safety precautions............................................................. 4 1.1. Information regarding the use of loudspeakers....................... 4 2. M6 loudspeaker.................................................................. 5 2.1. Product description................................

  • Page 4

    1.1. Information regarding the use of loudspeakers potential risk of personal injury never stand in the immediate vicinity of loudspeakers driven at a high level. Professional loudspeaker systems are capable of causing a sound pressure level detrimental to human health. Seemingly non-critical sound ...

  • Page 5

    2.1. Product description the m6 is a high performance stage monitor employing an integrated"12/1.3" exit coaxial driver design with neodymium magnet and constant directivity horn loading. Its dispersion of 50° x 80° (hor. X vert.) provides an accurately defined coverage area on stage. Used upright t...

  • Page 6

    2.3. Operation notice! Only operate d&b loudspeakers with a correctly configured d&b amplifier, otherwise there is a risk of damaging the loudspeaker components. Applicable d&b amplifiers: d80/d20/d12/d6/10d/30d. Application setup cabinets per channel m6 passive m6 (dual channel or mix top/sub mode)...

  • Page 7

    Active operation ("2–way active" mode) selecting "2–way active" mode with the m6 setup enables up to two m6 cabinets to be driven actively by the respective amplifier. In "2–way active" mode separate lf and hf signals are routed to the amplifier channels. Pins 1+/1– of both nl4 output connectors (ep...

  • Page 8

    2.4. Dispersion characteristics the graphs below show dispersion angle over frequency of a single m6 cabinet plotted using lines of equal sound pressure (isobars) at –6 db and –12 db. The characteristics refer to monitor operation. When used as a front-of-house system, the horizontal dispersion corr...

  • Page 9

    2.5. Technical specifications m6 system data frequency response (–5 db standard) 65 hz - 17 khz frequency response (–5 db cut mode) 95 hz - 17 khz max. Sound pressure (single cabinet, 1 m, free field) with d6/10d/e-pac passive mode 132 db with 10d active mode 133 db with d80/d20/d12/30d passive mode...

  • Page 10

    3.1. Eu conformity of loudspeakers (ce symbol) this declaration applies to: d&b m6 loudspeaker, z0820 manufactured by d&b audiotechnik gmbh. All production versions of these types are included, provided they correspond to the original technical version and have not been subject to any later design o...

  • Page 12

    D2605.En .01, 09/2017 © d&b audiotechnik gmbh www.Dbaudio.Com.