D&R Lyra Maintenance Manual - page 15
Index
Lyra Maintenance Manual. D&R Electronica Weesp B.V. tel. +31 294 418041.
info@d-r.nl
V1.0.0.3: 18 May 2004.
• Peak Led now works. The peak led will go on when the level reaches 17dBFS
(3dB below Fullscale).
• Fixed bug regarding encoder 5 (in an 8 Fader control surface).Pushing the encoder
button resulted in a chip card security level change
V1.0.0.4: 8 June 2004.
• The FPGA now displays a version string in the “System Information” page of the
Web server.
V1.0.0.5: 24 Nov 2005.
• Added SNMP community names in the “CobraNet Settings” page.
• Added compatibility for CobraNet CM-2 module, this requires FPGA version1.2.
• Added Sub pre switch in “Global Settings”.
• Lyra now also checks MfgID and ProdID.
• Snapshot format changed. Previously saved snapshots do not work anymore..
V1.0.0.6: 1 March 2005.
• Fixed error in FTP transfer which resulted in 0 Byte files size when trying to save
Snapshot.
• Added FTP command CDUP
• Changed FTP reply of Anonymous login to 230 instead of 200.
V1.0.0.7: 3 May 2005
.
• When Idle level is given full access (all boxes ticked in “Security Settings” pages
you will Not see a log in screen.
• Updated the CobraNet CM-2 module web page.
• CobraNet Remotes now work between a CM-1 and CM-2 modules.
• Due to reorganisation of the flash it is now possible to see COPIER.BIN when
using an FTP program.
• Added Update&Reboot button in “Network Settings”.
• An IP address with a “0” in it is now valid.
• New channel “mono” modes added, Mono (Left+Right), Mono from Left channel
only, Mono from Right channel only.
• Clear Log button added on Connection Log page.