D.T.Systems Ultra-e 2010 Owner's manual - How to Test Your Collar
16
How to Test Your Collar
A)
Place the test lamp on the electrodes of the receiver (as shown below).
B)
Set the stimulation to level 4 or 5.
C)
Push Button II.
D)
A red light on the test light should light up and the unit will either vibrate
or sound a “Beep”.
Trouble Shooting Questions & Answers
1) Q : My Collar’s range is not as far as when I first bought the unit.
A : (a) Test batteries. They may be low.
(b) Fully extend transmitter antenna.
2) Q : All of a sudden, “Nick” (momentary stimulation) works like
continuous stimulation.
A : This indicates a low battery in receiver unit. You may continue
to use the unit until it stops working.
3) Q : The unit is not working after I replaced the battery.
A : You might have installed the batteries incorrectly. Re-read the
section of this manual on “How to Change the Battery” very
carefully and try again.
4) Q : When I hold the Magnet to the M to turn the unit on it emits a
continuous string of quick beeps.
A : This indicates that the battery is almost dead. Simply replace the
battery.
5
Ultra-
e
TM
Model and Function
Ultra-
e
2020
Button Functions:
# I
- “Nick”
# II - Continuous Stimulation & Vibration Simultaneously
# III - Vibration only
# IV - Intensity Level adjustment
(See page 11 for instructions on how to change Ultra-
e
TM
batteries)