Da-Lite Senior Electrol Instruction Book

Other manuals for Senior Electrol: Instruction Book, Instruction Book

Summary of Senior Electrol

  • Page 1

    Da-lite screen company, inc. 3100 north detroit street post office box 137 warsaw, indiana 46581-0137 phone: 574-267-8101 800-622-3737 fax: 574-267-7804 www.Da-lite.Com e-mail: info@da-lite.Com instruction book for senior electrol® the da-lite difference..

  • Page 2: Save These Instructions

    Pre-installation 1 installation hangers (if required) 1. Make sure one hanger is approximately 25" from end of case (motor end). 2. Make sure second hanger is approximately 11 1 ⁄ 2 " from opposite end of case. 3. Place a third hanger on the center line of fabric. 4. Make sure hangers are placed to ...

  • Page 3

    Note: adjustments should not be necessary to screen in the rolled up or closed position. If necessary, use the following procedures: picture surface rolls too far into case 1. Lower picture surface approximately two feet with operating switch. 2. Place operating switch in “off” position. 3. Turn the...

  • Page 4

    Senior electrol ® instructions 3 side view end view bottom view outlet box suggested slot width picture surface wall or ceiling type hanger 12 3 ⁄ 16 12 3 ⁄ 16 3 ⁄ 4 3 ⁄ 4 3 ⁄ 4 3 ⁄ 4 3 ⁄ 4 11 3 ⁄ 8 ± 1 ⁄ 16 18 5 ⁄ 8 2 9 1 ⁄ 2 ± 1 ⁄ 4 “b“ 3 ⁄ 4 hinged access panel in bottom (for all wiring & adjustm...

  • Page 5

    Senior electrol ® installation 4 up limit switch down limit switch black black black black black black (down) red (up) black (down) capacitor red red (up) white white (common) up up adj. Down adj. White white black with yellow down off internal wiring external wiring to be completed by installer red...

  • Page 6

    Troubleshooting symptom 1. Screen will not operate or will not go “down”. 2.Motor hums. Cause (a) blown fuse. (b) tripped circuit breaker. (c) improper wiring to operating switch. (d) improper wiring to junction box in screen. (e) thermal overload tripped (exces- sive overheating). (f) burned out mo...

  • Page 7

    6 troubleshooting symptom 3. Screen will not move “up.” motor does not hum. Motor hums. Cause (a) blown fuse or tripped circuit breaker. (b) no power between red and white leads in junction box. (c) thermal overload tripped. (d) burned out motor winding. (e) temporary binding. (f) burned out capacit...

  • Page 8

    Troubleshooting symptom 9. Inconsistent stopping points. Cause (a) limit switch travel plate not mov- ing. (b) excessive end play in lead screw of limit switch assembly. Solution (a) tighten set screws located on nylon gears (drives limit switch). (b) tighten nut between adjusting knobs. Tighten lea...