DAB DRENAG 1000 Instructions For Installation, Maintenance And Use

Summary of DRENAG 1000

  • Page 1

    Istruzioni per l'installazione e la manutenzione instructions de mise en service et d'entretien instructions for installation and maintenance installationsanweisung und wartung instructies voor ingebruikname en onderhoud pokyny k inŠtalÁcii a ÚdrŽbe ИНСТРУКЦИИ ПО МОНТАЖУ И ТЕХНИЧЕСКОМУ БСЛУЖИВАНИЮ k...

  • Page 2

    Italiano franÇais applicazioni dati tecnici e limitazioni d’uso avvertenze installazione installazione feka vs-vx installazione drenag 1000-1200 allacciamento elettrico controllo del senso di rotazione (3 ~) avviamento regolazione dell’interruttore a galleggiante precauzioni manutenzione e pulizia c...

  • Page 3

    English 17 instructions for installation and maintenance installation and functioning must comply with the safety regulations in force in the country in which the product is installed. The entire operation must be carried out in a workmanlike manner. Failure to comply with the safety regulations not...

  • Page 4

    English 18 warnings 1. Use is allowed only if the electric system is in possession of safety precautions in accordance with the regulations in force. The appliance is not intendend for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience an...

  • Page 5

    English 19 3. Connect the delivery pipe or hose directly to the pump mouth. If the pump is used in fixed installations it is advisable to connect it to the pipe with a coupling so as to facilitate disassembly and reinstallation. If a hose is used, fit a threaded hosetail on the pump mouth. Wrap the ...

  • Page 6

    English 20 3. When the pump is to be in a fixed installation, with a float, a check valve must always be fitted in the delivery pipe. This is also advisable on pumps with manual operation. Electric connection caution! Always follow the safety regulations. 1. Ensure that the mains voltage is the same...

  • Page 7

    English 21 ensure that the stop level does not uncover the strainer. (fig.5) precautions 1. The intake strainer must always be in place during pump operation. 2. The pump should not be started more than 20 times in one hour so as not to subject the motor to excessive thermal shock. 3. Danger of fros...

  • Page 8

    English 22 checking and changing the sealing oil feka vs-vx to perform this operation, slacken the six screws (45) so as to be able to remove the strainer cover , the strainer and the pump body (1). Retain the o-ring (28) and the nuts (51). Using a suitable spanner, unscrew the impeller retaining nu...

  • Page 9

    English 23 checking and changing the sealing oil drenag 1000-1200 to perform this operation you must unscrew the six screws of the flange (45) so as to be able to remove the flange (105) and the outer jacket (77). Unscrew the three screws of the filter cover (136) and remove the cover (92) and the f...

  • Page 10

    English 24 modifications and spare parts any modification not authorized beforehand relieves the manufacturer of all responsibility. All the spare parts used in repairs must be original ones and the accessories must be approved by the manufacturer so as to be able to guarantee maximum safety of the ...

  • Page 11

    135 modello / modèle / model /modell / model /modelo modell / model / Модель qy¥} / malli / model prevalenza / hauteur d'élévation / head up förderhöhe / overwicht / prevalencia maximal pumphöjd / manometrik yükseklik / Напор x¥tk{a / nostokorkeus / wysoko ść ci ś nienia hmax (m) 2 poles 50 hz hmax...

  • Page 12

    Dab pumps ltd. Units 4 & 5, stortford hall industrial park, dunmow road, bishop’s stortford, herts cm23 5gz - uk salesuk@dwtgroup.Com tel.: +44 1279 652 776 fax: +44 1279 657 727 dab pumpen deutschland gmbh tackweg 11 d - 47918 tönisvorst - germany info.Germany@dwtgroup.Com tel.: +49 2151 82136-0 fa...