Summary of NOVA

  • Page 1

    Owner’s manual c us.

  • Page 2: Declaration of Conformity

    Dab pumps reserves the right to make modifications without notice declaration of conformity (it) dichiarazione di conformitÀ ce noi, dab pumps s.P.A. - via m.Polo, 14 – mestrino (pd) – italy, dichiariamo sotto la nostra esclusiva responsabilità che i prodotti ai quali questa di- chiarazione si rifer...

  • Page 3: 1.  Safety Measures

    Dab pumps reserves the right to make modifications without notice 1. Safety measures before starting the pump, read this instruction booklet carefully. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience ...

  • Page 4: 1.  Safety Measures

    Dab pumps reserves the right to make modifications without notice overload protection: the pump has a thermal overload safety device. In the event of any overhea- ting of the motor, this device automatically switches off the pump. The cooling time is roughly 15 to 20 minutes, then the pump automatic...

  • Page 5: 4. Recommendations

    Dab pumps reserves the right to make modifications without notice to ensure the proper operation of the pump, it is important to comply with the following recommendations: • the pump must never be allowed to run dry. • never leave the pump in operation when the delivery pipe is clogged. • place the ...

  • Page 6: 5.  Technical Data

    Dab pumps reserves the right to make modifications without notice 5. Technical data model power input 60 hz p1 max p2 in a max submersion hp w hp w nova 4100 1 x 115~ 0.9 670 0.5 380 7.1 22 ft nova 4100 1 x 230~ 0.9 670 0.5 380 3.2 22 ft model a b h dnm gas packing dimensions cable lenght weight lbs...

  • Page 7: 7. Troubleshooting

    Dab pumps reserves the right to make modifications without notice fault possible causes solutions the pump does not run. Power cord unplugged. Plug cord securely into the socket and check if there is voltage on the line. Impeller jammed. Disconnect the power cord, disassemble hydraulic part and chec...

  • Page 8: Www.Dabpumps.Com

    Via marco polo, 14 - 35035 mestrino (pd) italy - tel. +39.049.5125000 - fax +39.049.5125950 www.Dabpumps.Com nov a-4100-usa - 02/2016 on-line selection tool dab pumps ltd. Unit 4 and 5, stortford hall industrial park, dunmow road, bishops stortford, herts cm23 5gz - uk salesuk@dwtgroup.Com tel. +44 ...