Dacor DRT304S Use And Care Manual - page 12
10
Cleaning the Rangetop (cont.)
Knobs and Trim Rings
WARNING
Never block the holes in the control panel behind the
knobs. Doing so will impair the flow of combustion air
and adversely affect burner operation, possibly creating a
hazardous condition.
To prevent damage, do not expose the knobs to direct
flame, hot utensils or other sources of heat.
• Turn the knobs to the off position before remov-
ing them for cleaning or replacement.
Care and Cleaning
Accessories and Replacement Parts
• To remove the knobs, gently grasp each knob
and pull straight out, off of the valve shaft.
• Wash the knobs regularly with a solution of
warm soapy water. Dacor recommends hand
dishwashing liquid.
• Clean the outside edges of the trim rings while
the knobs are removed. Do not remove the trim
rings. Wipe them with a soft damp rag. Use cau-
tion to avoid getting moisture into the control
panel behind the trim rings.
• Replace the knobs according to the directions on
page 5. Be sure to install the knobs in their
proper positions.
Description
Dacor Part Number
Dacor Stainless Steel Cleaner
A302
Wok ring
AWR4
Griddle for model DRT304S
ADRT14
Grill for model DRT304S
AGDRT14
Griddle for model DRT366S
ADRT12
Grill for model DRT366S
AGDRT12
To order parts and accessories, contact your Dacor dealer or visit www.everythingdacor.com.
Before You Call for Service
Problem Solution Guide
Problem
May Be Caused By
What to Do
Nothing works.
Rangetop not connected to
electrical power.
Check to make sure power cord is con-
nected to electrical outlet.
Power to electrical outlet is off.
Turn on power at circuit breaker or fuse
box. Check for tripped breaker or blown
fuse.
Power outage.
Contact power company.
Igniters do not spark (no
clicking sound).
Power not supplied to unit.
See Nothing Works above.
Wet or dirty igniter(s).
Clean and dry igniter and burner assem-
bly according to Care and Cleaning
section.
Burner goes out at low set-
ting.
Air intake holes obstructed.
Check to make sure air holes above knobs
are not blocked.
Low gas pressure.
Contact gas company to have pressure
tested.