Dacor EG366 Planning Manual - Eg366, Eg486
All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
EG366, EG486
Renaissance
36” and 48” Wide
Slide-in Gas Rangetops
Document # PG04-001
Revised 10/20/14 Page 4/4
CABINET/COUNTERTOP CUTOUT DIMENSIONS WITH DOWNDRAFT VENT - TOP VIEW
CABINET/COUNTERTOP CUTOUT DIMENSIONS
WITH DOWNDRAFT VENT - SIDE VIEW
Model
No.
B - Cutout
Width
D - Hole
Offset
E - Downdraft
Vent Cutout
EG366
36”
(91.4 cm)
16 5/8”
(42.2 cm)
33 1/2”
(85.1 cm)
EG486
48”
(121.9 cm)
20 13/16”
(52.9 cm)
43 1/2”
(110.5 cm)
Model
No.
Approved Downdraft
Vent Models
EG366
ERV36, ERV3615, PRV36
EG486
ERV48, PRV48
Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated
Non combustible rear
wall recommended
10” (2.5 cm) min. to
combustible wall
above countertop,
both sides
Cabinet face
below countertop
overhang
3/8” (1.0 cm) min.
countertop overhang
2 5/8”
(6.7 cm)
Hole 1/2” dia. (1.3 cm),
2 places, through platform
for hold down bolts
1/2” (1.3 cm)
countertop
overhang
1” (2.5 cm) thick mounting platform min.
Open to below to allow for downdraft
vent, gas and electrical connections
Countertop
Countertop
1/2” (1.3 cm)
countertop
overhang
2” (5.1 cm)
1” (2.5 cm)
11 7/16”
(29.1 cm)
15”
(38.1 cm)
24 5/8”
(62.5 cm)
CL
D
D
E
B
CL
CL
CL
Stiffener
Cabinet face
Control panel
Countertop
Dacor approved
downdraft vent
IMPORTANT: See downdraft
vent installation instructions
for duct system
layout/planning
EG366 or EG486 rangetop
3/8” min. (1.0 cm)
space behind
downdraft vent
chassis to clear
stiffener
3/8” min. (1.0 cm)
flat countertop overhang
required behind cutout
Minimum
countertop
height:
30 1/4"
(76.8 cm)
IMPORTANT:
Use only the downdraft vents specified.