STEP 2
Planning Installation - Base Construction Structure (continued)
Locate the electrical supply box within reach of the 48 inch (1219mm) long power cord so the connection is accessible when the grill is
completely installed in the enclosure.
For self contained LP-gas supply systems, refer to the detail in the Gas Installation section of this manual.
LP-gas cylinder shall be ventilated by openings at the level of the cylinder valve and the floor level. The effectiveness of the openings for
purposes of ventilation shall be determined with the LP-gas supply cylinder in place. Refer to installation details in this manual.
Plan to install the grill in a base structure that has one of the following structural details:
1. One side of the base structure enclosure completely open.
2. For an enclosure having four sides, a top, and bottom:
•
At least two ventilation openings at cylinder valve level shall be provided in the side wall, equally sized, spaced at 180 degrees and
unobstructed.
•
Each opening shall have a total free area of not less than 10 square inches (254 square mm).
•
Ventilation openings shall be provided at floor level and shall have a total free area of not less than 10 square inches (254 square
mm). If the ventilation openings at floor level are in a side wall, there shall be at least two openings. The bottom of the openings
shall be at floor level and the upper edge no more than 5 inches (127mm) above the floor. The openings shall be equally sized,
spaced, and unobstructed.
The LP cylinder valve shall be readily accessible for hand operation. A door on the enclosure to gain access to the cylinder vales is
acceptable, provided it is non-locking and can be opened without the use of tools.
The enclosure for the LP-gas cylinder shall isolate the cylinder from the burner compartment to provide shielding from radiation, a flame
barrier, and protection from foreign materials such as hot drippings.
There shall be a minimum clearance of 2 inches (51mm) between the floor of the LP-gas cylinder enclosure and the ground.
The design of the outdoor cooking enclosure must allow the LP-gas cylinder to be connected, disconnected and the connections inspected
and tested outside the cylinder enclosure.
Connections, which may be disturbed when installing the cylinder in the enclosure can be leak tested inside the enclosure.
Internal mounting means shall be provided on the outdoor gas grill for mounting the LP-gas supply cylinder. If the outdoor grill is not in use,
the gas must be turned off at the supply cylinder.
Storage of an outdoor grill is permissible only if the cylinder is disconnected and removed from the outdoor cooking appliance.
Optional Finish Trim (Model AOGT)
An optional finish trim can be installed on the countertop to finish the sides and back of the countertop opening. The stainless steel finish trim
can be caulked to the countertop and should be secured to the base enclosure with flat head decking screws (supplied by others). Center the
trim within the cutout dimensions noted in this manual, then utilizing the deck screws and holes located along the vertical sides of the finish
trim install them securely to the base enclosure countertop sub-straight. Install the trim before installing the grill.
NOTE:
The rotisserie mounting bracket on the
right side of the grill chassis and the
slot in the right side finish trim must
line up for proper rotisserie motor
installation. (Selected models only)
EOG303/36/52 Cutout Dimensions
Side View
Junction
Box
Trim frame
(accessory)
3/4" (19mm)
Min. to any
material
8" (203mm) Min. to combustibles
2" (51mm) Min. to non-combustible
1"
(25mm)
23" (584mm)
24" (610mm)
EOSB162 Cutout Dimensions
Side View