Dacor Millenia DHW301 Installation Instructions Manual - page 11
9
Insidetheexhaustoutlet(s)therearemetalorplastic
7.
damperflaps.Theflapsclosetohelppreventback-
draftswhenthebloweristurnedoff.Removethe
shippingtapeandmakesurealltheflapsopenand
closefreelybeforeproceeding.
f
inal
i
nstallation
Connecting to the Duct Work
WARNING
Donotusescrewstoattachtheductworktothe
•
hoodexhaustoutlet.Useducttapeonly.Screwsmay
preventthedamperflapsonthetopofthehoodfrom
opening.
Installthelastoftheductworkbetweenthehood
•
exhaustandthepreviouslyinstalledductwork.Attach
theducttothehoodexhaustwithducttapealone.Use
sheetmetalscrews(notprovided)andducttapeonthe
remainingjoints.
I
nstallatIon
I
nstructIons
Final Electrical Installation
WARNINGS
Toavoidelectricalshockorfirehazard,makesure
•
thepowersupplyatthefuseorjunctionboxisturned
offbeforeproceedingwithfinalinstallation.
Improperconnectionofthehoodelectricalwiringmay
•
createanelectricshockorfirehazardandmayresult
indamagetothehoodselectricalsystem.
Donotgroundthehoodtotheneutral(white)power
•
supplywire.Connectthehoodgroundwiretoa
separate,properlygroundedwireinstalledbya
licensedelectrician.
Connect the house power supply wires to the wires
coming out of the top of the hood junction box:
Connectthewhitewirefromthehoodtotheneutral
1.
(white)powersupplywire.
Connecttheblackwirefromthehoodtothehot(black)
2.
powersupplywire.
Connectthegreenandyellowwirefromthehoodto
3.
thehouseground(green)wirefromthejunctionbox.
BLACK TO BLACK
YELLOW/GREEN
TO GREEN
WHITE TO WHITE