Dacor Millennia MRES30 Installation Instructions Manual - page 4
3
2
36" (914mm) Recommended
30" (762mm) Min.
25"
(635mm)
30 1/16"
(764mm) 10"
(254mm)
14"
(356mm)
Hood
30" (762mm)
Min.
10" (254mm) Min.
to combustible side
walls above the range
(both sides)
13"
(330mm)
Max.
1
10"
(254mm)
Top of
finished
counter
Vertical
combustible
surface
18" (457mm)
Min.
Freestanding Cabinet Dimensions and Clearances to Combustible Surfaces
Planning the Location
NOTE:
The shaded areas shown in the
illustrations, denote the location
of the electrical junction box/
receptacle. This is the suggested
location. For replacement
purposes, the location of the
existing electrical supply may be
utilized provided that it does not
interfere with the sides or rear of
the range. Verify that the electrical
service meets local building
codes.
Access to the remote circuit breaker panel/
fuse box, with the range in place and
operating, must also be allowed for in
the installation. Any openings in the wall
behind the appliance and in the floor under
the appliance must be sealed.
The electrical junction box/receptacle must
be located so that it does not interfere
with the range when it is installed and
under operation. In addition, the junction
box must be located so the range can
be removed for service when the conduit
supplied with the unit is attached to the
junction box. Do not lengthen the conduit
or wiring provided with the range.
All dimensions shown are based on
standard American cabinets 36 inches
(914mm) high at the finished countertop
by 24 inches (610mm) deep, with a 25
inch (635mm) overall countertop depth.
When installing the range into nonstandard
cabinets, minimum clearances shown in
the diagrams must be maintained.
Cabinet and Countertop Preparation
NOTES:
1. If cabinet storage space is to
be provided directly above
the range, the risk of personal
injury may be reduced by
installing a ventilating hood
that projects horizontally a
minimum of 5 inches (127mm)
beyond the face of the
cabinets.
2. The range may be installed
flush to the rear wall. We
recommend installing a non-
combustible material on the
rear wall above the range
and up to the vent hood. It
is not necessary to install
non-combustible materials
behind the range below the
countertop height.
3. The minimum distance from
the sides of the range above
the countertop to combustible
side walls must be at least 10
inches (254mm).
Utilities may be located:
1. In the lower left corner of the adjacent
right cabinet. (Recommended)
2. Alternate location, in the lower right
corner behind the range.
Contact your local building department
to verify compliance with local code
interpretation.