PRObLEM
MAY bE CAUSED bY
WHAT TO DO
Nothing Works. Control panel is not lit.
Blower does not work.
Power to hood is off.
Turn on power at junction or fuse box.
Check for tripped breaker or blown
fuse.
Hood main power switch is off.
Make sure hood main power switch is
on (see page 3).
Power outage.
Call electric company.
Hood not connected to electric power. Have qualified electrician connect
hood to electric power.
Light does not work. Control panel is
not lit.
See
Nothing Works
above.
Light does not work. Control panel is lit. Loose light bulb.
Check to make sure that both prongs
on the light bulb are inserted into the
holes on the light socket (see
page 6).
Light bulb burned out.
Replace light bulb (see page 6).
Blower does not draw heat and smoke
properly.
Filters clogged or dirty.
Check filters. Make sure they are
completely clean and not blocked by
foreign objects.
Blower set to low setting.
See
Operating Instructions
section.
Damper jammed shut or duct work
clogged.
Consult with a qualified installation
professional.*
Blower shuts off by itself after being left
on for a long time.
Normal operation.
To conserve energy, the blower
automatically turns itself off if it is left
on for four hours continuously.
Blower does not work. Control panel
not lit.
See
Nothing Works
above.
Blower does not work. Control panel lit. Blower malfunction.
Call for service.
* The duct work connected from the range hood chimney to outside the house or building required to vent heat and
smoke is not manufactured, warranted or serviced by Dacor
®
. The customer is responsible for having a qualified installer
install and maintain the duct work.