Dacor Renaissance Series MRES30S Installation Instructions Manual - page 10
8
Installation Instructions
Removing the Oven Door
To make the range easier to move, remove the door to reduce
weight.
WARNING
• Do not attempt to disengage the hinge catches with the
door removed from the oven. The hinge springs could
release causing personal injury.
• Do not lift or carry the oven door by the handle.
1. Open the door to its fully opened position.
2. Rotate the catch over the retaining arm on both hinges.
3. Lift the oven door to about a 30 degree angle from the
horizontal position.
4. Pull the door away from the oven while continuing to lift.
Remove the Kick Panel
Remove the screw at each top corner of the kick panel. Lift up
slightly on the panel and pull forward to remove..
30º
2) Lift door up to 30º angle, then
pull door away from the oven
1) To remove door, rotate catch up
Catch
Electrical Connection
WARNING
• This range must be connected to a grounded, metallic,
permanent wiring system. Alternatively, a grounding
conductor should be connected to the grounding terminal or
lead on the appliance.
• Do not use an extension cord with this appliance. Such use
may result in fire, electrical shock, or other personal injury.
• Do not install a fuse in the neutral or ground circuit. A fuse
in the neutral or ground circuit may result in an electrical
shock hazard.
• Do not ground the appliance to a gas supply pipe or hot
water pipe.
• A grounded cold water pipe must have metal continuity to
electrical ground and must not be interrupted by insulating
materials. Any insulating materials must be jumped with a
length of No. 4 copper wire securely clamped to bare metal
at both ends. See below.
1. Before proceeding, turn off power to the circuit to which the
oven will be connected at the circuit breaker or fuse box.
2. Position the range directly in front of the cabinet cut out.
3. Feed the appliance conduit into the electrical junction box and
attach it using a UL approved strain relief.
4. Depending upon local codes, utilize one of three methods to
connect the appliance to the electrical power:
◊ Connect to a four-wire electrical system
◊ Connect to a three-wire electrical system, where local
codes permit
◊ Connect to a three-wire electrical system with external
ground, according to local codes.
Meter or other
insulating device
Bare metal
Metal
water pipe
Clamps
Insulated Pipe Jumper
No. 4
copper wire