Manual de servicio acondicionador de aire dsc-097l dsc-127l.
Content s p 1 1 contents.....................................................................................1 service and maintenance ..........................................................2 exploded views and part list .....................................................15 disassembly and reas...
1 1 3 3 2 2 1 1 3 3 2 2 air conditioner no use for a long time. Start fan only for 3-4 hours to comple- tely dry the inside of the indoor unit. Set cool mode or heat mode, and select the highest setting tempera- ture, then fan turns. Turn off air conditioner, unplug the power plug. Otherwise, the ac...
3 3 1 1 1 4 4 3 3 2 2 1 1 4 4 3 3 2 2 filters should be cleaned once every two weeks. Take out filters. Clean filters with a vacuum cleaner or by typing them gently. ( if they are very dirty, wash them in warm water below 45 dissolved with neutral scouring agent.) clean filters with clean water, the...
Controls specification 1 1 2 2 abbreviation ts: setting temperature tr: room temperature ti: indoor defrost sensor temperature to: outdoor defrost sensor temperature operation of main board cool mode if tr > ts, cool operation is activated. Compressor and outdoor fan are turned on. Indoor fan runs a...
Outdoor de-ice after 40 minutes of continuous heating operation, if to -4 , the outdoor de-ice operation is activated. Compressor is turned off. Indoor fan speed reduces to low speed. After 30 seconds delay, 4 way value and outdoor fan will be turned off, indoor fan reduces to low speed, 15 seconds ...
Timer timer off can only be set when the system is operating. Timer on can only be set when the system is off. The maximum set time is 12 hours. Changing of on/off state will cancel timer mode. Sleep mode in cool mode, after sleep mode is set, ts will increase 1 in first hours, will increase 2 in se...
Manual swing (stepping motor) if the indoor fan is operating, the louver will swing or can be stopped at a preferred location in any mode. The louver change location follow the order of : if a command is received, the system will respond with a beep. Buzzer in cool mode, if tr-ts if 0 no change in s...
Manual operation button 3 3 operation of control panel on indoor unit every press of this button will turn the system on or off. System led light when system is operating, the run light is on. When system is off, the light is off. (cool only type) every time the switch is pressed, it changes in sequ...
Disassembly and reassembly stop operation of the air conditioner and remove the power cord before repairing the unit indoor unit no parts procedure remark 1 front grille 1.Stop the air conditioner operation and block the main power. 2.Contract the second finger to the left ,and right handle and pull...
5.Loosen the earth screw in evaporator. 8.Separate the electrical box from the indoor unit. 4.Take all the connector of the pcb upper side out. 3.Loosen the screw of the inside terminal board , separate the board. 6.Pull softly the indoor pipe temperature sensor out from the pipe casing. No parts pr...
Disassembly and reassembly 3 3.Separate the evaporator from the indoor unit. Ass’y tray drain 1.Push the left and right hooks to make the ass’y pulled out. 4 evaporator 2.Separete the ass’y tray drain from the body. 1.Push the left hook and separate the left part out of evaporator. 3.Separate the fa...
Disassembly and reassembly 1 cabinet 1.Turn off the unit and remove the power cable. 2.Remove the upper cabinet, the front cabinet and back cabinet. 2.Separate the propeller fan from fan motor. 1.Remove the nut flange. (turn to the right to remove as it a left turned screw ) 1.Loosen the fixing scre...
If problems can not be corrected after doing below items, please stop the air conditioner, contact our air conditioner specially eng- aged service centre nearest to you to get help. Is there a fault ? Fault analysis air conditioner does not operate at all. Does power fail ? Is plug out ? Does power ...
Indoor unit fan stops for about 10 minutes during heating. It is defrosting of the outdoor unit coil.It should complete this process in about 10 minutes at most.( it freezes when outdoor temperature is low and humidity is high. ) issues cracking sounds the friction sounds caused by expansion and con...
Indoor unit exploded views and parts list model :dsc-097l 15 15 model :dsc-127l.
Indoor unit exploded views and parts list 16 16 model :dsc-097l n o . P a r t n a m e q u a n t it y i t e m c o d e 1 a ir filter 1 k f r 3 3 g . 1 . 1 .2 - 8 2 f r o n t p a n e l 1 k f r 3 3 g . 1 . 1 .1 - 1 (5 2 d ) 3 r igh t big ligh t ass em bly 1 k f r 3 3 g . 1 . 1 .2 . 1 4 r igh t sm all li...
Exploded views and parts list outdoor unit 17 17 model :dsc-097l model :dsc-127l.
Exploded views and parts list 18 18 outdoor unit model :dsc-097l model :dsc-127l no. Part name quantity item code 1 air outlet grille 1 kfr20w.1.1-2 2 front panel 1 kfr20w.1.1-1 3 left handle 1 sl05-01 4 top panel 1 kfr20w.1.2-1 5 fan screw nut m6 (left revolve) 1 gb41-86 6 outdoor fan 1 kfr20w.1.5....
Remote controller 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 10 10 quantity 1 1 1 1 1 1 1 1 1 1 4 ass’y pcb remocon screw case up conduct rubber inlay lcd lcd screen spring battery name back body number 11 10 1 2 3 4 5 6 7 8 9 back cover conduct rubber 9 9 11 11 spring battery exploded views and parts list 19 ...
Y l w /g r n r c c compressor mf mf y l w /g r n fan motor red ylw blu y l w /g r n motor mc mc blu n n terminal bed to indoor unit wht 2 2 blu blu wht wht s s blu red capacitor run outdoor unit wiring diagram wiring diagram 20 20 model :dsc-097l dsc-127l.
D r iv e a /o c o n v e r t e r m a il p c b l e d p c b r e m o t e c o n t r o l l e r a c p o w e r in p u t o u td o o r f a n m o to r 4 .7 5 v 1 2 v r e m o te a n d e m e rg e n c y m o d e s le c to r s le e p la m p t im e r la m p t e m p e ra tu re la m p h e a tin g la m p c o o lin g la...