Daewoo DOB-092RH Service Manual

Summary of DOB-092RH

  • Page 1

    Service manual split system air conditioner model: dob-092rh dob-122rh s/m no. : r1a1g0a004 mar., 2006 ✔ caution : in this manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to ppl(parts pric...

  • Page 2: Contents

    Contents service and maintenance ................................................................1 trouble shooting .............................................................................2 trouble display................................................................................2 control ...

  • Page 3

    4. Wipe the filter with a soft cloth soaked in water and dry it up in the shade. 1. Do not use gasoline, thinner or other chemicals to clean the unit. As these substances may cause damage to the finish and deformation of plastic parts. 2. Do not wash the unit directly under a tap or using a hose. 3....

  • Page 4

    -water full indicator lamp blinks, water tank is full. Dump the water out of the water tank. -room temperature is higher than the setting temperature. (electric heating mode) reset the temperature. -the windows or doors in the room are not closed. -there are heat sources inside the room. -exhaust ai...

  • Page 5: Abbreviation

    2 abbreviation ts: setting temperature tr: room temperature td: defrost sensor temperature operation of main board cool mode if tr > ts, cool operation is activated. Compressor is turned on and the fan runs at the setting speed. If tr ts-1 cool operation is terminated. Compressor and fan are turned ...

  • Page 6

    Explode view and parts list 4.

  • Page 7

    Name quantity 28 number 1 2 3 4 5 6 7 8 9 10 11 29 30 quantity number 31 32 33 34 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 35 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 name front panel electrical control assembly air outlet hole left cover cap supporting panel for left/r...

  • Page 8

    Disassembly and reassembly stop operation of the conditioner and remove the power cord before repairing the unit. 6. Loosen the screw of the electric control board and take out the electric control board. 1. Switch off the air conditioner and remove the power plug. 2. Remove the fixing screw of the ...

  • Page 9

    Wiring diagram kyw-02 7 ry-y room thermistor pipe thermistor ry-y dob-122rh dob-092rh.

  • Page 10

    Daewoo electronics corp. 686, ahyeon-dong mapo-gu seoul, korea c.P.O. Box 8003 seoul, korea telex: dwelec k28177-8 cable: “daewooelec” printed date: mar. 2006.

  • Page 11: About This Manual

    담 담 당 당 이윤석님 t te el l m mo od de el l s/m_수출용 b bu uy ye er r d do ob b- -009922r rh h,, d do ob b- -112222r rh h 1차 06.4.14 6차 2차 7차 일 일 정 정 3차 8차 4차 9차 5차 10차 제 제 판 판 인 인쇄 쇄 규 규 격 격 m me em mo o 0 06 6..4 4..1 14 4- - 1 1.. 겉 겉표 표지 지와 와 뒷 뒷표 표지 지 만 만들 들어 어 주 주십 십시 시오 오..((겉 겉표 표지 지 맨 맨앞 앞,, 뒷 뒷표 ...