Daewoo DSA-095L Service Manual

Summary of DSA-095L

  • Page 1

    Manual de servicio split acondicionador de aire modelo:.

  • Page 2: Contents

    Contents 1. Specifications ..........................................................................................................2 2. Outline and dimensions .........................................................................................6 3. Operation ......................................

  • Page 3: 1. Specifications

    2 model dsa-095l item function cooling class t1 power ac 230v/ 60hz capacity kj/h 9,000 btu/h 8,531 dehumidification l/h 1.1 running current a 3.6 power input w 800 type rotary model qk125kb ✳ (lge) capacitor 25µf / 400vac indoor unit outdoor unit type cross flow fan propeller fan capacitor 1.0µf 40...

  • Page 4

    3 model dsa-125l, 125p item function cooling class t1 power ac 230v/ 60hz capacity kj/h 12,500 btu/h 11,848 dehumidification l/h 1.35 running current a 4.7 power input w 1,010 type rotary model qk156ka ✳ (lge) capacitor 35µf/ 370vac division indoor unit outdoor unit type cross flow fan propeller fan...

  • Page 5

    4 model dsa-185l, 185p item function cooling class t1 power ac 230v/ 60hz capacity kj/h 17,500 btu/h 16,588 dehumidification l/h 2.0 running current a 7.2 power input w 1,620 type rotary model qj250ka ✳ (lge) capacitor 35µf/ 370vac division indoor unit outdoor unit type cross flow fan propeller fan ...

  • Page 6

    5 model dsa-245l, 245p item function cooling class t1 power ac 230v/ 60hz capacity kj/h 23,500 btu/h 22,275 dehumidification l/h 2.7 running current a 10.0 power input w 2,220 type rotary model qp325kbb (lge) capacitor 40µf/ 400vac division indoor unit outdoor unit type cross flow fan propeller fan ...

  • Page 7: 2. Outline and Dimensions

    6 750 plate mounting remocon connecting pipe grille insert 179 245 remote controller frame grille body plate mounting 2. Outline and dimensions 1 indoor unit ◆ dsa-095l mode sleep on/off timer enter/ cancel fan speed turbo/mild fan dir. Remocon.

  • Page 8

    7 insert grille frame grille body connecting pipe plate mounting 815 195 285 ◆ dsa-125l, 125p mode sleep on/off timer enter/ cancel fan speed turbo/mild fan dir. Remocon.

  • Page 9

    8 ◆ dsa-185l, 185p 1035 205 322 453 ¿‹ Æ˘˜ ˙` ”fi `⁄˘˙ `⁄„«…–‚fi‚ ˜ ‰˙‡»– ‚Ø– ‚– ‰˙‡»– ‚ ˆ … connecting pipe filter-l filter-r grille insert body plate mounting 453 1035 mode sleep on/off timer enter/ cancel fan speed turbo/mild fan dir. Remocon.

  • Page 10

    9 connecting pipe body f rame gr ille gr ille inser t plate mounting 430 710 1080 filter-l filter-r remocon ◆ dsa-245l, 245p 200 298 mode sleep on/off timer enter/ cancel fan speed turbo/mild fan dir. Remocon.

  • Page 11

    10 ◆ installing the installation plate unit : mm • dsa-245l, 245p • dsa-185l, 185p • dsa-125l, 125p • dsa-095l.

  • Page 12: Outdoor Unit

    11 2 outdoor unit ◆ dsa-095l outlet foot cushion cabinet front cabinet side panel t o p guide support svc cover servise v alve inlet outlet inlet 256 286 324 539 549 460 654.

  • Page 13

    12 ◆ dsa-125l, 125p, 185l, 185p inlet outlet outlet foot cushion cabinet front cabinet side panel t o p guide support svc cover servise v alve 580 800 320 360 400 589 615 inlet.

  • Page 14

    13 ◆ dsa-245l, 245p inlet 325 350 380 673 697 outlet outlet foot cushion cabinet front cabinet side panel t o p guide support svc cover servise v alve inlet 549 872.

  • Page 15: Name and Function of Parts

    14 1 name and function of parts indoor unit 3. Operation ◆ dsa-095l fan direction (up/down) connection cover remove cover to access the ac connection from this unit to the outdoor unit. On of f en te r ca nc el tim er re se t fa n d ir . Fa n s pe ed m od e sl ee p on /o ff te m p. Electrostatic fil...

  • Page 16: Indoor Unit

    15 indoor unit ◆ dsa-125l, 125p removes small dust and generates (-) ions. (dsa-125p) electrostatic filter removes dust particles from the air (dsa-125l) electric dust collector (air clean plasma) air cleaning filters removes dust and prohibits germs. Emergency/remote switch slide to select the desi...

  • Page 17: Indoor Unit

    16 indoor unit ◆ dsa-185l, 185p indoor cover deodorizing filter removes bad smells from the air. Test/emergency/ remote switch slide to select the desired position. Indicators indicate the ac setting. Remote sensor power plug lcd remote controller air cleaning filters removes dust and prohibits germ...

  • Page 18

    17 indoor cover deodorizing filter removes bad smells from the air. Emergency/ remote switch indicators indicate the ac setting. Remote sensor power plug lcd remote controller air cleaning filters removes dust and prohibits germs. Air out air in fan direction (up/down) mo de sl ee p on /o ff tim er ...

  • Page 19: Name of Each Button

    18 name of each button 2 remote controller mode sleep plasma on/off timer enter/ cancel fan speed turbo/mild display displays information pertaining to unit. ( dsa-125p, 185p, 245p) turbo/mild press to be colder the unit. Plasma buttons press to clean the polluted air. (dsa-125p, 185p, 245p) timer e...

  • Page 20: Off-Timer

    19 if you set time in off-timer mode, the unit will stop at the set time. If you set time in on-timer mode, the unit will run at the set time. (1) range of setting temperature: 18~32°c (2) setting temperature: operating temperature of compressor (3) during the time of test operating, fan (indoor, ou...

  • Page 21: Fan Speed (Indoor Unit)

    20 fan speed (indoor unit) (1) motor speed (high speed, normal speed, low speed). (2) remote controller setting fan speed. (auto, l, m, h, natural) (3) relation of operating mode between fan speed. (legned: x-no relation) (4) automatic operation if the unit is set in 'auto' mode, the unit operates a...

  • Page 22: Sleep Mode

    21 (1) when the remote controller is lost, damaged or the battery is discharged, the emergency operation can be used to run the unit. (2) the setting conditions of emergency operation are as follows. • operation mode: quick • preset temperature:18°c • fan speed: high * you cannot operate with remote...

  • Page 23: Auto Mode

    22 frost prevention of indoor unit when the unit operates at low ambient temperature, frost may appear on the evaporator. When the indoor coil temperature is lower than 0°c at the end of 10 minutes of continuous compressor operation from the start, the microcomputer of the unit stops the compressor ...

  • Page 24: Dehumidification Mode

    23 1) cooling mode 1 fan speed: super high speed 2 air discharge direction: fixed 3 set temperature: 18°c (fixed) 4 compressor and outdoor fan the air discharge direction procedure is below fixed up/down up/down fixed dehumidification mode air discharge direction(only remocon operation) quick mode(p...

  • Page 25: Self-Diagnostic Function

    24 self-diagnostic function the control will contain diagnostic test to verify the integrity of the system. (1)error code display pattern 1 on lamp: blink self diagnostic function description 1. Sensor error open or short circuit of sensors (room and indoor coil sensor) open : micom, input voltage 0...

  • Page 26: 4. Wiring Diagram

    25 4. Wiring diagram indoor unit ◆ dsa-095l ◆ dsa-125l ◆ dsa-185l, 245l.

  • Page 27: Indoor Unit

    26 indoor unit ◆ dsa-125p ◆ dsa-185p ◆ dsa-245p.

  • Page 28: Outdoor Unit

    27 outdoor unit ◆ dsa-095l ◆ dsa-125l, 125p ◆ dsa-185l, 185p ◆ dsa-245l, 245p.

  • Page 29: 5. Control Block Diagram

    28 5. Control block diagram ◆ dsa-095l, dsa-125l, 125p.

  • Page 30

    ◆ dsa-185l, 185p 29.

  • Page 31

    ◆ dsa-245l, 245p 30

  • Page 32: 6. Electric Circuit Diagram

    31 2 1 3 i.D.C s r swing motor room air sensor remote controller trans- former rl1 comp. Relay triac overload pro- tector compressor outdoor unit fan motor terminal block n l indoor coil sensor display part control part signal receiver fmc cmc y l indoor unit fan motor 6. Electric circuit diagram ◆ ...

  • Page 33: Description

    32 description 1. After the power on/off button is pressed once, the relay and triac are turned on or off per the remote control setpoint. – triac is controlled per the fan speed selection. – relay is controlled per the operation mode selection. 2. If the power on/off button is pressed once more, th...

  • Page 34: 7. Trouble Shooting

    33 7. Trouble shooting outdoor unit does not run?(note. 1) does the compressor run normally? Indoor unit does not run(note 1) check the failure code according to the self diagnostic (note 2) is the unit display mormal? Check the failure code according to the self-diagonostic (note 2) normal check th...

  • Page 35: Self-Diagnostic Function

    34 note 1) 1 neither indoor unit nor outdoor unit runs. Check the following points first. (there are following case in normal operation) a. Is the timer mode set the "timer on". B. Is the timer mode set the "timer-off" and the time had passed? 2 neither outdoor fan nor compressor runs while indoor f...

  • Page 36

    35 confirm following statement. When the unit operate normally, sometimes the outdoor unit and indoor unit cannot operate. 1 check the function select switch. Is it timer mode? 2 the function select switch locate the sleep mode and is the setting time over? 3 is the setting mode dehumidifier mode? 4...

  • Page 37

    36 check rotation of indoor fan rotate indoor fan by hand check input voltage of fan motor connector at power p.C.B check the winding resistance of indoor unit fan motor check the fan motor capacitor check the connecting wire of indoor fan motor run again check the starting of indoor fan motor run a...

  • Page 38

    37 confirm following statement. When the unit operate normally, sometimes the outdoor unit and indoor unit cannot operate. 1 is the setting temperature proper? 2 is the unit during 3min. Time delay of compressor. 3 during frost prevention of lndoor unit. 4 during dehumidifier mode. Outdoor fan and c...

  • Page 39: Only Compressor Do Not Run

    38 - check the following at cooling mode check the voltge between and of indoor unit terminal y l check the voltge between and of outdoor unit terminal y l check the wiring of outdoor unit check the compressor (check the winding resistance) check the compressor capacitor check the connecting wire be...

  • Page 40: 8. Pcb Driving Description

    39 ◆ dsa-095l, dsa-125l, 125p 8. Pcb driving description.

  • Page 41

    40 ◆ dsa-185l, 185p.

  • Page 42

    41 ◆ dsa-245l, 245p.

  • Page 43

    ◆dsa-095l part list (control pcb assy) no. Part code part name spec. Q'ty unit remark bd1 ds1nb80--- diode bridge s1nb80,800v 1 ea bz1 3105698200 buzzer dp-2520ba 1 ea ca1 cn5xd104m- c-array 6p(f5)x 104z 1 ea ca2 cn4xd104m- c-array 5p(f4)x 104z 1 ea ca3 cn3xd104m- c-array 4p(f3)x 104z 1 ea cap1 cmxz...

  • Page 44

    No. Part code part name spec. Q'ty unit remark pcb 3104398104 pcb control 162.5x140x1.6t 1 ea pt1 1tlp560j-- ic photo coupler tlp 560j 1 ea r1 rd-4k101j- r carbon film 1/4 100 ohm j 1 ea r11 rd-4k103j- r carbon film 1/4 10k ohm j 1 ea r12 rd-4k102j- r carbon film 1/4 1k ohm j 1 ea r13 rd-4k102j- r c...

  • Page 45

    44 ◆dsa-125l, 125p part list (control pcb assy) no. Part code part name spec. Q'ty unit remark bd1 ds1nb80--- diode bridge s1nb80,800v 1 ea bz1 3105698200 buzzer dp-2520ba 1 ea ca1 cn5xd104m- c-array 6p(f5)x 104z 1 ea ca2 cn4xd104m- c-array 5p(f4)x 104z 1 ea ca3 cn3xd104m- c-array 4p(f3)x 104z 1 ea ...

  • Page 46

    45 no. Part code part name spec. Q'ty unit remark pc2 1tlp421--- ic photocoupler tlp421 1 ea pcb 3104398113 pcb control 180x126x1.6t 1 ea pt1 1tlp560j-- ic photo coupler tlp 560j 1 ea r1 rd-4k101j- r carbon film 1/4 100 ohm j 1 ea r11 rd-4k103j- r carbon film 1/4 10k ohm j 1 ea r12 rd-4k102j- r carb...

  • Page 47

    46 ◆dsa-185l, 185p part list (control pcb assy) no. Part code part name spec. Q'ty unit remark ca1 cn5xd104m- c-array 6p(f5)x 104z 1 ea ca2 cn3xd104m- c-array 4p(f3)x 104z 1 ea cc1 ccxe1e104m c-cera 104z 25vdc 1 ea cc13 cdxe1h104m c-multi cr501b-z5u,104z,50v 1 ea cc2 ccxe1e104m c-cera 104z 25vdc 1 e...

  • Page 48

    47 no. Part code part name spec. Q'ty unit remark r1 rd-4k103j- r carbon film 1/4 10k ohm j 1 ea r10 rd-4k562j- r carbon film 1/4 5.6k ohm j 1 ea r11 rd-4k102j- r carbon film 1/4 1k ohm j 1 ea r12 rd-4k102j- r carbon film 1/4 1k ohm j 1 ea r13 rd-4k102j- r carbon film 1/4 1k ohm j 1 ea r14 rd-4k102j...

  • Page 49

    48 no. Part code part name spec. Q'ty unit remark bz1 3105698200 buzzer dp-2520ba 1 ea c1 clv-b3104m c-line across 275v 104k(pilkor) 1 ea c2 clv-b3104m c-line across 275v 104k(pilkor) 1 ea cc1 ccxe1e104m c-cera 104z 25vdc 1 ea cc2 ccxe1e104m c-cera 104z 25vdc 1 ea cc3 ccxe1e104m c-cera 104z 25vdc 1 ...

  • Page 50

    49 ◆dsa-245l, 245p part list (control pcb assy) no. Part code part name spec. Q'ty unit remark bz1 3105698200 buzzer dp-2520ba 1 ea ca1 cn5xd104m- c-array 6p(f5)x 104z 1 ea ca2 cn4xd104m- c-array 5p(f4)x 104z 1 ea ca3 cn3xd104m- c-array 4p(f3)x 104z 1 ea cc 3108803500 pin gp881206-2(250) 1 ea cc1 cc...

  • Page 51

    50 no. Part code part name spec. Q'ty unit remark j1 14 3109400100 jumper 10mm 14 ea j1~14 3109400100 jumper 10mm 14 ea l1 52c1374001 coil 130uf 3a 1 ea osc 5pcrtl8ms0 resonator crtl8.00msot 1 ea pcb 3104398102 pcb main 160.5*140*1.6t(42) 1 ea pt1 1tlp560j-- ic photo coupler tlp 560j 1 ea r1 rd-4k10...

  • Page 52

    ◆ led pcb ass`y (model : dsa-095l) no part code part name spec q'ty unit remark cc1 cdxe1h104m c-multi cr501b-z5u,104z,50v 1 ea cn1 3108804800 wafer smaw250-08 1 ea hold 3103002700 holder led abs 1 ea l1 ddls05031d led dlso-5031d(red) 1 ea l2 ddlg05031d led dlg-5031d(grn) 1 ea l3 ddls05031d led dlso...

  • Page 53: Power Supply(1)

    52 power supply(1) description dc power supply in circuit needs +12v and +5v. +12v is used for compressor driving relay, triac driving photo triac, buzzer driving swing, sweep motor. Ac voltage of secondary power transformer is rectified by bridge diode, and it is filtering by main condensor ce1. Fi...

  • Page 54: Sensor(3)

    53 room temperature and evaporator temperature sensor input description number 24, 25 of micom is terminal of a/d convertor input. Room temperature and evaporator temperature is sensing by change of thermister resistance, micom is put in 5v by ratio between r10 (12.7k Ω ) and r11 (12.7k Ω ). Relatio...

  • Page 55: Triac Driving(4)

    54 triac driving(4) description number 38 terminal of micom is put out pulse output, by way of buffer it is driving photo triac is supplied trigger signal. Trigger test of triac is detected zero cross part of ac input and it is triggered from zero cross part to time delay part according to fan speed...

  • Page 56: Remote Controller(5)

    55 description signal from remote controller put in only control data signal at micom terminal of number 33, which is gotten fid of carrier (38khz) from receive module. Signal wave repeat third as following fig 5-1. But in secondary wave custom code is reversed face. Leader code custom code data cod...

  • Page 57: Micom Power Supply(7)

    56 description micom power is supplied 5v at number 42 using vdd, number 19, 20 vsing oscillator, cc13 is noise filter. Micom power supply(7) vdd 42 ce5 10 µ f 16v cc11 104 cc13 104 + 5v 41 40 39 22 21 19 osc 8mhz 20 vss micom.

  • Page 58: Reset(8)

    57 description voltage less than about 0.8v put in micom terminal of number 18 and then micom reset. Reset ic detect power on and voltage less than 4.25v, and then send reset signal. Reset(8) r13 5.6k 1k r12 18 cc9 ce4 4.7uf/50v ic5 7042p 10.3 micom 4.25v h l t t power on vcc (+5v) delay time for po...

  • Page 59: Buzzer Driving(10)

    58 description micom 34 terminal put out buzzer driving pulse, its output is driving buzzer through buffer. Ocillatory frequency of buzzer is selected by internal micom. This unit is setting at 4khz. Vcc 12v kid 65004 micom 34 6 11 r4 1k bz1 buzzer driving(10) description selecting function is as fo...

  • Page 60: Zero Crossing Detect(11)

    59 description it defect zero cross part of trans output voltage, transistor tr1 is used to put in the micom. Detail driving is as following fig 11-1. R19 is resistance to limit current. Micom trans output d5 d6 r2 5.6k 1 2 cc4 103 tr1 krc120m 1 2 1 2 3 2 1 r3 10k r27 1k vcc 31 detect point h the nu...

  • Page 61: Stepping Motor Driving(12)

    60 description there are one stepping motor for flap (up and down) and it is used 4 face drive method. It is driving as following fig 12-1. (ring count method of 8 status) Ø 4 Ø 3 Ø 2 Ø 1 b+ 6 5 4 3 2 1 12v ic6 kid65004 cn13 1 micom 2 3 4 m1 for swing Ø 4 Ø 3 Ø 2 Ø 1 fig 12-1 (normal rotating) (reve...

  • Page 62

    Error no error no error no no no no yes select on/off button select mode button select fan speed button select fan dir. Button power supply test start power supply again check the following battery spring micom pcb lcd is display at the beginning on? Is display at the beginning on? Is it normal? Is ...

  • Page 63

    62 (0.5~24 hour) error no select timer on button select timer enter button select cancel button select on/off button select off (timer) button select sleep button select sleep button test ok! Is lcd display off? Is it normal display? Timer is all display off? Is it normal? Sleep mode display on? Is ...

  • Page 64: (1) U1 (Micom)

    63 (1) u1 (micom) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 vdd (xtout)p22 (xtin)p21 (int5/stop)p20 p17 p16 (tc2)p15 (ppg)p14 (dvo)p13 (int2/tc1)p12 (int1)p11 (into)p10 (ain7)p67 (ain6)p66 (ain5)p65 (ain4)p64 (ain3)p63 (ain2)p62 (ain1)p61 (ain0)p60 varef p77(hso) p76(hsck) p75(so) p74(si...

  • Page 65

    64 (2) u2, 4 (kid65004) darlington arrays (3) u8 (kia7805p) : voltage regulator (5vdc) (4) u7 (kia7812p) : voltage regulator (12vdc) in1 1 16 out 1 in2 2 15 out 2 in 3 3 14 out 3 in 4 4 13 out 4 in5 5 12 out 5 in6 6 11 out 6 in7 7 10 out 7 gnd 8 9 common free wheeling diodes common 10.5k Ω 7.2k Ω 3k...

  • Page 66: (5) U9 (Kia7042P) : Reset Ic

    65 (5) u9 (kia7042p) : reset ic kia70 42p outline input ground output vcc 1 3 2 out gnd.

  • Page 67: Indoor Unit

    66 1 indoor unit procedures photos 1. Stop the air conditioner and disconnect the power cord from the wall outlet. 2. Removing the insert grille and frame grille. (fig 1~2) 1 draw up the insert grille and remove it. 2 loosen one screw for fixing the cover ter-block. 3 loosen two screw at the frame g...

  • Page 68

    67 ◆ dsa-185l, 185p procedures photos 1. Stop the air conditioner and disconnect the power cord from the wall outlet. 2. Removing the insert grille and frame. ! Loosen three screws for fixing the the insert grille and frame. (pull out the frame cap before loosening three screws) (fig 1) @ loosen thr...

  • Page 69

    68 procedures photos 7. Removing the blower. After doing above procedures: ! Loosen a screw for fixing holder bearing. @ remove the blower. Fig 8 fig 7.

  • Page 70

    69 procedures photos 1. Stop the operation of the air conditioner and disconnect the power cord from the wall outlet. 2. Removing the insert grille and frame grille. (fig 1~2) 1 draw up the insert grille and remove it. 2 loosen the screws fixed at the cover ter-block. 3 loosen two screw at the frame...

  • Page 71: Outdoor Unit

    2 outdoor unit 70 ◆ dsa-095l procedures photos 1.Stop the operation of the air conditioner and disconnect the wire from indoor unit to outdoor unit. 2. Disassemble the case. (fig 1~2) 1 remove the top panel. (loosen thirteen screws) 2 remove the front cabinet. (loosen six screws) 3 remove the side c...

  • Page 72

    71 ◆ dsa-125l, 125p, dsa-185l, 185p procedures photos 1.Stop the operation of the air conditioner and dis connect the wire from in door unit to out door unit. 2. Disassemble the case. (fig 1~2) 1 remove the top panel. 2 remove the side cabinet. 3 remove the front cabinet. 3. Removing the propeller f...

  • Page 73

    ◆ dsa-245l, 245p 72 procedures photos 1.Stop the operation of the air conditioner and disconnect the wire from in door unit to out door unit. 2. Disassemble the case. (fig 1~2) 1 remove the top panel. 2 remove the front cabinet. 3 remove the side cabinet and back cabinet. 3. Removing the propeller f...

  • Page 74

    73 3 exploded view & parts list (indoor unit) ◆ indoor unit exploded view: dsa-095l.

  • Page 75

    74 ◆ indoor unit part list; dsa-095l no part code part name q'ty spec remark 1 3100400301 body 1 hips t2.0 2 3108008700 motor idu 1 ydk-8-4a 3 3101500400 cushion motor 2 cr ø30 4 3106400400 bearing plastic ass`y 1 5 3100053700 fan cross flow ass`y 1 ø90.0 x l540 6 7485401012 set screw 1 6s-4x10-e mf...

  • Page 76

    75 26-1 ◆ indoor unit exploded view: dsa-125l, 125p.

  • Page 77

    76 ◆ indoor unit part list; dsa-125l, 125p no part code part name q'ty spec remark 1 3110400301 body 1 hips t2.0 2 3118003500 motor idu 1 rb13b(220v, 50/60v) 3 3106400400 bearing plastic ass`y 1 4 3110046000 fan cross flow ass`y 1 san+g.F 30% ø100xl615 5 7485401012 set screw 1 6s-4x10-e mfzn 6 31130...

  • Page 78

    77 t 0 o w a p y 16-1 7 5 q j 4 s z k h e g 1 6 l c r 8 9 i x u d 2 3 ; f ◆ indoor unit exploded view: dsa-185l, 185p.

  • Page 79

    78 ◆ indoor unit part list; dsa-185l, 185p no part code part name q'ty spec remark 1 3100400101 body 1 hips 2 3107600100 flap top 1 hips 3 3107600200 flap under 1 hips 4 3106500401 blade vertical 16 pp (gy171a) 5 3103000500 holder motor r 1 hips 6 3103000600 holder motor l 1 hips 7 3103000700 holder...

  • Page 80

    79 28 -1 28 27 ◆ indoor unit exploded view: dsa-245l, 245p.

  • Page 81

    80 ◆ indoor unit part list; dsa-245l, 245p no part code part name q'ty spec remark 1 3100400600 body 1 2 3108007510 motor idu 1 ic-9430dwkf7a 3 3101500400 cushion motor 2 cr i.D30 4 3106400200 bearing plastic ass`y 1 o.D37.0*i.D6.0 5 3100076400 fan cross flow ass`y 1 od 100*l864 6 7485401012 set scr...

  • Page 82

    81 4 exploded view & parts list (outdoor unit) ◆ outdoor unit exploded view: dsa-095l.

  • Page 83

    82 82 ◆ outdoor unit part list; dsa-095l no part code part name q'ty spec remark 1 3100014720 pan base ass`y 1 secc t1.2 2 3106000900 comp. Bolt 3 m8 x l46.5 3 3102100800 foot 1 secc t1.2 4 3108104ae0 comp. Grommet 3 epdm 5 3117104470 compressor ass`y 1 qk125k** lg 6 7400208411 comp. Washer 3 m8.4 x...

  • Page 84

    83 ◆ outdoor unit exploded view: dsa-125l, 125p.

  • Page 85

    84 ◆ outdoor unit part list; dsa-125l, 125p no part code part name q'ty spec remark 1 3110007500 pan base ass`y 1 2 3102100201 foot 4 secc t2.0 3 3106000100 bolt comp. 3 m8xl46.5 4 3117104390 compressor ass`y 1 qk164k** lg 5 3108104ae0 comp. Grommet 3 6 7400208411 washer plain 3 m8.4 x 22 x t1.6 7 7...

  • Page 86

    85 ◆ outdoor unit exploded view: dsa-185l, 185p.

  • Page 87

    86 ◆ outdoor unit part list; dsa-185l, 185p no part code part name q'ty spec remark 1 3110007500 pan base ass`y 1 2 3102100201 foot 4 secc t2.0 3 3106000100 bolt comp. 3 m8xl46.5 4 3117104390 compressor ass`y 1 qj250k** lg 5 3108104ae0 comp. Grommet 3 6 7400208411 washer plain 3 m8.4 x 22 x t1.6 7 7...

  • Page 88

    87 ◆ outdoor unit exploded view: dsa-245l, 245p.

  • Page 89

    88 ◆ outdoor unit part list; dsa-245l, 245p no part code part name q'ty spec remark 1 3100031102 base pan ass`y 1 secc t1.2 2 3102100901 foot 2 secc t1.6 3 3106003100 bolt comp 3 m8*p1.0*l48 4 3117141200 compressor ass`y 1 qp325kbb lg 5 3108104ae0 comp. Grommet 3 6 7400208412 washer plain 3 id8.4*od...

  • Page 90: Control Box Assembly

    89 5 control box assembly 3 8 7 4 5 1 9 q 6 2 0 ◆ dsa-095l.

  • Page 91

    90 ◆ dsa-095l no part code part name q'ty spec remark 1 3114302010 control pcb ass’y 1 2 3108914100 terminal block 1 jxo-ch-3p 3 3106900300 capacitor sh.M.B 1 1.0µf 400vac 4 3104896300 sensor id ass’y 1 ptm-kd43c-d2 5 3101301700 power cord ass’y 1 250v 15a 6 3102797610 harness 1 i/d comp 7 310279791...

  • Page 92

    91 9 ◆ dsa-125l, 125p.

  • Page 93

    92 ◆ dsa-125l, 125p no part code part name q'ty spec remark 1 3110504000 control box 1 hips t2.0 (black) 2 3101301700 power cord 1 250v 15a 3 3114302020 control pcb ass’y 1 4 3118900200 terminal block 1 jxo-ch-2p 5 3108003910 stepping motor 1 24byj-48-1 6 3112716100 harness led pcb 1 ul1007 8*26awg ...

  • Page 94

    93 ◆ dsa-185l, 185p.

  • Page 95

    94 no part name spec q’ty part code remark 1 control box ass’y 1 3100058210 2 box control-2 abs (version2) 1 3100506900 3 pcb trans ass’y dwa-220v 1 5epv633110 4 screw tapping t2s trs 4x12 mfzn 3 7122401211 5 capacitor idm 1.2µf/400v 1 3106900210 6 screw tapping t2s trs 4x24 mfzn 1 7141402411 7 term...

  • Page 96

    96 ◆ dsa-245l, 245p no part code part name q'ty spec remark 1 3100077060 control pcb ass’y 1 2 3101200400 clamp power cord 1 da-5n 3 3113701800 voltage generator 1 4 3102797910 harness earth 1 green/yellow l170mm 5 3102714400 harness capacitor 1 6 3102704410 harness comp signal 1 ul1015#18 7 3102704...

  • Page 97

    95 ◆ dsa-245l, 245p.

  • Page 98

    Deawoo electronics co., ltd 686, ahyeon-dong mapogu, seoul, korea. C.P.O. Box 8003 seoul korea telex: dwelec k28177-8 cable:"daewooelec" fax: +82-2-364-5588 tel: +82-2-360-7114, 8114 http://www.Dwe.Daewoo.Co.Kr s/m no. : 3113914300 printed date: mar. 2004.