Dsb-f0983elh-v dsb-f1283elh-v dsb-f1883elh-v dsb-f2483elh-v.
Safety precautions 3 safety instructions 1 indoor unit 4 outdoor unit 4 display introduction 5 preset 2 safeguarding the envirionment 2 identification of parts 4 maintenance 6 protection 7 troubleshooting 8 select the installation locations 10 indoor unit installation 11 outdoor unit installation 15...
1 safety instructions to guarantee the unit work normally, please read the manual carefully before installation, and try to install strictly according to this manual. Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner. After installing, the consume...
2 preparation before use the air conditioner has an auto-restart function. Each time after the remote control is replaced with new batteries or is energized, auto presetting heat pump.If the air conditioner you purchased is a cooling only one, heat pump remote controller can also be used. Remote con...
Safety precautions symbols in this use and care manual are interpreted as shown below. Be sure not to do. Pay attention to such a situation. Grounding is essential. Warning: incorrect handling could cause a serious hazard, such as death, serious injury, etc. 3 do not use the power supply circuit bre...
The figures in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner you have selected. Air intake air outlet air outlet louver vertical adjustment louver horizontal adjustment air filter remote controller connection cord ...
The symbols may be different from these models, but the functions are similar. Display introduction 5 running indicator it lights up when the ac is running. It flashes during defrosting. Timer indicator it lights up during set time. Sleep indicator it lights up in sleep mode. Compressor indicator it...
Emergency button 10 10 the symbols may be different from these models, but the functions are similar. 5 display introduction on/off to let the ac run or stop by pressing the button. Tlseries 2 3 4 9 1.
Turn off the appliance first before disconnecting from power supply. It is necessary to clean the air filter after using it for about 200 hours. Clean it as follows: front panel maintenance air filter maintenance cut off the power supply never use volatile substance such as gasoline or polishing pow...
Features of heating mode preheat defrost at the beginning of the heating operation, the airflow from the indoor unit is discharged 2-5 minutes later. In heating operation the appliance will defrost (de-ice) automatically to raise efficiency. This procedure usually lasts 2-10 minutes. During defrosti...
Trouble analysis does not run no cooling or heating air ineffective control does not operate immediately peculiar odor a sound of flowing water cracking sound is heard spraying mist from the outlet the compressor indicator lights on constantly, running indicator flashes and indoor fan stops. The uni...
9 distance from ceiling distance from wall should be over 50mm distance from the wall air intake distance from the wall should be over 250mm air intake distance from the wall over 250mm air outlet distance from the wall should be over 500mm should be over 200 mm should be over 50mm distance from flo...
Outdoor unit outdoor unit indoor unit indoor unit pipe length is 15 meters max. Pipe length is 15 meters max. Be less than 5m be less than 5m height should height should 10 installation instructions select the installation location location for installing outdoor unit where it is convenient to insta...
Piping direction 1 2 3 4 trough note: when installing the pipe at the directions 1,2 or 4, saw the corresponding unloading piece off the indoor unit base. Unloading piece saw the unloading piece off along the trough 11 installation instructions indoor outdoor wall hole sleeve ( hard polythene tube p...
12 installation instructions piping joints thermal insulation: wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape. Piping thermal insulation: a. Place the drain hose under the piping. B. Insulation material uses polythene foam over 6mm in thickness. Note: drain ...
13 4. Connecting of the cable outdoor unit indoor unit 1) remove the access door from the unit by loosening connect the power cord to the indoor unit by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit connection. The screw. Connect the wire...
14 installation instructions make sure that the color of the wires in the outdoor unit and terminal no. Are the same as those of the indoor unit. 7k* 12k* model ~ wiring diagram 7k 30k model ~ indoor unit outdoor unit terminal terminal power connecting cord 1(n) 2(l) 3(si) blue(gray) black brown yel...
Fix with bolts and nuts tightly on a flat and strong floor. If installed on the wall or roof, make sure to fix the supporter well to prevent it from shaking due to serious vibration or strong wind. 3. Outdoor unit piping connection 4. Outdoor unit cable connection (see previous page) remove the valv...
(1) unscrew and remove caps from 2 and 3-way valves. (4) start vacuum pump for 10-15 minutes until reaching a vacuum of 10 mm hg absolutes. (6) open 2-way valve ,1/4 turn, then close it after 10 seconds. Check tightness of all joints using liquid soap or an electronic leak detector. (7) turn 2 and 3...