Daewoo DWA-182R Use & Care Manual

Other manuals for DWA-182R: Service Manual

Summary of DWA-182R

  • Page 1

    1 please observe the following instructions. 1. Operate the power button to run or stop the unit. - do not operate main power switch or auxiliary power switch to do it. 2. Do not stick anything into the air outlet or inlet. - it is a danger and it can cause trouble. 3. You must frequently open doors...

  • Page 2: Table of Contents

    2 1. General specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. Names of major components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3. Operation instructions . . . . . . . . . . . . . ....

  • Page 3: Names of Major Components

    3 names of major components 6 3 1 2 7 4 8 5 no part name 1 air filter 2 grille front 3 cabinet 4 blade vertical no part name 5 panel control 6 remote controller 7 blade horizontal 8 air vent • dwa-182r.

  • Page 4: Operation Instructions

    4 operation instructions room air-conditioner fan turbo cooling room temp temp desired temp timer sensor mode power fan speed auto swing temp./timer display • it displays the temperature and the timer. Mode display • it displays the operating mode. Remocon signal receiver temperature set • it is the...

  • Page 5

    5 operation instructions (continued) ✽ do not use the remote controller before the lamp lights. If use, the “ °f ” temperature display can change to “ °c ” temperature display (only “ °f ” temperature display model). Remocon signal transmitter timer/cancel • everytime you push this button, timer is ...

  • Page 6

    6 operation instruction(continued) function power on push power button cooling mode push the ‘mode’ button until ‘cooling’ lamp lights. Change desired room temperature push the ‘temp ▲▼ ’ button. Change ‘fan speed’ push the ‘fan speed’ button. Operation 1. The unit starts working. (it is delayed 3 m...

  • Page 7

    7 operation instructions (continued) function fan mode push the ‘mode’ button until ‘fan’ lamp lights. On/off auto swing push the ‘auto swing’ button. Turbo mode push the ‘mode’ button until ‘turbo’ lamp lights. Off timer push the ‘timer/cancel’ button when unit is working. (remocon only) operation ...

  • Page 8

    8 operation instructions (continued) function on timer push the ‘timer/cancel’ button when unit is off. (remocon only) sleep mode push the ‘sleep’ button in ‘cooling’ mode. (remocon only) operation 1. Timer is changed to as follows by pushing “timer/cancel” button. (1hr → 2hr → 3hr → 4hr → 5hr → 6hr...

  • Page 9

    9 operation instructions (continued) • how to insert batteries remove the cover from the back of the remote controller. • slide the cover according to the arrow direction insert two battaries. • be sure that the (+) and (–) directions are correct • be sure that both batteries are new re-attach the c...

  • Page 10: General Information

    10 • air flow around unit check in door grill and outdoor louvers for air flow obstructions. Do not block air flow to and from unit. The outdoor coil should be checked and periodically cleaned for debris that may collect and block unit air flow. If air flow is obstructed or deflected back into unit,...

  • Page 11: Care and Maintenance

    11 • air filter clean the air filter, which removes dust inside the room. It should be washed at least once every week during operation. 1. Remove the air filter from the front grille by pulling up. 2. Clean air filter with a vacuum cleaner or lukewarm, soapy water. 3. Shake it when clean to remove ...

  • Page 12: Electrical Requirements

    12 • electrical grounding instructions this appliance is equipped with a three-prong(grounding) plug for protection against possible shock hazards. If a two-prong wall receptacle is encountered, the customer is required to contact a qualified electrician and have the two-prong wall receptacle replac...

  • Page 13: Installation Instructions

    13 • location of installation 1. Install the unit at a place having sufficient strength to support the unit securely. 2. Do not install the unit at a place where leakage of combustible gas is suspected. 3. If the air conditioner is operated in an atmosphere containing oils (including machine oil), s...

  • Page 14: Installation Instructions

    14 • how to remove the front grille 1. Remove the air filter from the front grill by pulling up. 2. Remove two screw tapping from front grill (2 point) 3. Push the “latch position” at the right side of cabinet. (the latch position of the grill front and the cabinet is 4 point) 4. Separate the latch ...

  • Page 15

    15 7. If you need reinstall the front grill, do the reverse order in page 14. Installation instructions (continued) caution • when the front grille is reinstalled, the door vent should be in position first so that it would not be vent by grille. Fig. 5 door vent.

  • Page 16

    16 • how to install the drain cap install the drain cap like fig. Of the right side. There are two kinds of method to install the drain cap. The first method is that the shape of hole like it is good for the household. The second method is that the shape of hole is like it is good for the shop. • wi...

  • Page 17: Before Calling For Service

    17 when you find something wrong with your room air conditioner, please carefully check the following items. If you are unable to find the cause of trouble, contact your service dealer. Before calling for service difficulty • air conditioner do not operate. • little or no cooling • noisy unit • odor...

  • Page 18: Room Air Conditioner

    Model #: dwa-182r room air conditioner use & care manual window type room air conditioner please read carefully and thoroughly this manual before operating the unit. If you still have any difficulties or problems, consult your dealer for help or electronics. Please keep this manual well. W1.