Digitus Biometrics dbNEXII User Manual

Manual is about: Networked Access Control Solution. Networked Access Control Solution . Standalone Access Control Solution. Time and Attendance System

Summary of dbNEXII

  • Page 1

    User manual db nexus (dbnexii) - networked access control solution db nexus (dbnexiii) - networked access control solution db sentry (dbsai) - standalone access control solution db tracker (dbtri) - time and attendance system.

  • Page 2

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 2 of 27 table of contents initial setup............................................................................................................................. 3 using the unit to gain access ......................

  • Page 3

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 3 of 27 fcc notice for db nexus iii this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonab...

  • Page 4

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 4 of 27 initial setup › on a new unit, all fingerprint indexes are unused. › when a new unit is powered up, it will immediately go into the initial setup menu. The menu consists of a number of options that can be sel...

  • Page 5

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 5 of 27 if you have reached this stage following a firmware upgrade and wish to preserve the existing enrolled users, it is recommended that you choose no. If you select no, this completes the setup procedure. If you...

  • Page 6

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 6 of 27 print stored remove finger › remove the finger from the fingerprint scanner. › the head unit will then display: place finger on scanner › place the same finger on the scanner to verify the enrollment. › the h...

  • Page 7

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 7 of 27 using the unit to gain access all the digitus units are configurable as to which credentials are enabled or disabled. The dbnexii, dbsai and dbtri have 2 credentials, a pin number and a fingerprint. The dbnex...

  • Page 8

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 8 of 27 correct use of fingerprint correct placement of the fingerprint is important. Following these simple steps will ensure that you have a very high percentage success rate when attempting fingerprint verificatio...

  • Page 9

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 9 of 27 successful access once all credentials have been presented, a successful verification or identification will be indicated by 07/04/10 2:00pm access granted and displayed on the lcd, the status led on the head...

  • Page 10

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 10 of 27 entering the menu after initial setup other than at initial setup, the menus can be accessed by any enrolled manager in the following way: › press and release the # key. › present the first enabled credentia...

  • Page 11

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 11 of 27 add a user via the menus note. Before you add users, if you are going to want to restrict the permitted times a user will have access, you first need to go into the time mney and setup time codes. After you ...

  • Page 12

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 12 of 27 edit user enter id [ ] press the 1 (one) key. Follow the instructions on the lcd to edit the user. Deleting a user via the menus after you enter the menus, you will see the following displayed on the head un...

  • Page 13

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 13 of 27 unit configuration any settings that are specific to the unit can be set via the operations menu. User menu? Yes=1 no=0 press the 0 (zero) key, you see the following displayed: operations menu? Yes=1 no=0 pr...

  • Page 14

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 14 of 27 setting the unit's real-time clock via the menus after you enter the menus, you will see the following displayed on the head unit's lcd: user menu? Yes=1 no=0 press the 0 (zero) key until you see the followi...

  • Page 15

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 15 of 27 each day allows for up to 2 non-contiguous blocks of time to be entered for each day. If only a single block of time is required for a given day, leave the 2nd time code set to 00:00-00:00. Note that times a...

  • Page 16

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 16 of 27 setting the ip address via the menus after you enter the menus, you will see the following displayed on the head unit's lcd: user menu? Yes=1 no=0 press the 0 (zero) key until you see the following displayed...

  • Page 17

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 17 of 27 appendix 1 - menu maps.

  • Page 18

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 18 of 27.

  • Page 19

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 19 of 27.

  • Page 20

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 20 of 27.

  • Page 21

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 21 of 27.

  • Page 22

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 22 of 27.

  • Page 23

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 23 of 27 appendix 2 - troubleshooting head unit problems problem the following message is displayed on the head unit lcd: base status: cannot connect solution there is a communication problem between the head unit an...

  • Page 24

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 24 of 27 if after powering the unit back up, the same message is displayed, contact your vendor for support. ---------------------------/--------------------------- problem the following message is displayed on the h...

  • Page 25

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 25 of 27 solution there may be a wiring problem between the head unit and control unit. Check the cable that connects the head and control units together. Ensure the cable is wired "straight-thru", i.E. Terminal a on...

  • Page 26

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 26 of 27 problem when you power the control unit up you hear the buzzer sound for 1 second, the buzzer turns off and them immediately turns back on and stays on. Solution one of 3 conditions can cause this: 1.) the t...

  • Page 27

    Digitus biometrics, inc. User manual - models: dbnexii, dbnexiii, dbsai, dbtri page 27 of 27 solution the jumper on the control unit pcb is set incorrectly or is missing. Refer to the door sensor section of the installation manual for correct configuration of the jumper. ---------------------------/...