DigiWeight DWP-10000R User Manual - Chapter 2 Installation

Manual is about: Floor / Pallet Scale

Summary of DWP-10000R

  • Page 1

    A12-51007 v1.0 floor / pallet scale dwp-5500r (floor scale) dwp-102e (indicator) user manual.

  • Page 2: Content

    Floor / pallet scale - 1 - content chapter 1 main specification chapter 2 installation 2.0 scale base set up 2.1 front and back view of indicator 2.2 key functions 2.3 connecting load cell to indicator chapter 3 operation 3.1 power on & zero setting 3.2 manual zero setting 3.3 tare 3.4 accumulating ...

  • Page 3

    Floor / pallet scale - 2 - chapter 1 main specification 1. Model: dwp-5500r floor / pallet scale 2. Accuracy: grade Ⅲ, n=5000 3. Sample rate: 10 times / second 4. Load cell sensitivity 1.5 ~3mv / v 5. Scale interval: 1/2/5/10/20/50 for option 6. Display: 6 bits led ,6 state indicating signals 7. Pow...

  • Page 4: Chapter 2 Installation

    Floor / pallet scale - 3 - chapter 2 installation 2.0 scale base setup a. Open the scale base box (box 1) with a knife very carefully. Sharp blade may scratch the scale surface. B. Take out the scale feet (total 4 feet packed in the box inside the scale base).

  • Page 5

    Floor / pallet scale - 4 - c. Screw each foot onto the load cell at each corner of the scale base. D. Take out the indicator from box 2. Plug the scale serial cable into the socket on the back of the indicator. And use a screw driver to tighten the two screws of the plug. E. Plug in power to recharg...

  • Page 6: Chapter 3 Operation

    Floor / pallet scale - 5 - 2.3 connecting load cell to indicator 1. The 9-pin socket is used to hook up load cell, please refer to graph 2-3. 2. The 4-pin shielded cable is used, and the indicator does not have the function of long distance compensation. 3. Indicator must be reliably connected to lo...

  • Page 7

    Floor / pallet scale - 6 - 3.4 counting function (when f3 key=1) sampling: tare the weight of any container that is used and leave the container on the scale. Place samples on the scale. The quantity of the samples should match the options for the pre-set values: 10, 20, 50, 100 or 200 pieces. Press...

  • Page 8

    Floor / pallet scale - 7 - the high-limit and the low-limit are set as same value, the indicator will set alarm for one key point. If the high-limit is set higher than the low-limit, the indicator will set alarm for a weighing range. To set check-weighing parameters: when the indicator is off, turn ...

  • Page 9

    Floor / pallet scale - 8 - slp 5: the indicator will enter sleep mode if it is idle for 5 minutes. Slp 10: the indicator will enter sleep mode if it is idle for 10 minutes. Press [fun] to select and [tare] to move to the next parameter. 4.3 “f3 key” function switch press [fun] to enter function sele...

  • Page 10: Chapter 5 Calibration

    Floor / pallet scale - 9 - press [fun] to confirm and go to label format selection. Options: 1/2 “p11 fl”: weight adjustment for acceleration of gravity change. “p12 kb”: on: keyboard beep is on; off: keyboard beep is off “p13 ut”: unit setting. Default unit: lb/kg lb on/off u1 on/off u2 on/off (uni...