Dimplex DWF1203 Service Manual

Other manuals for DWF1203: Troubleshooting Manual

Summary of DWF1203

  • Page 1

    Service manual model dwf1203 part number 6908490100 7400580000r00 in keeping with our policy of continuous product development, we reserve the right to make changes without notice. © 2012 dimplex north america limited dimplex north america limited 1367 industrial road cambridge on canada n1r 7g8 1-8...

  • Page 2: Table of Contents

    2 www.Dimplex.Com always use a qualified technician or service agency to repair this fireplace. ! Note: procedures and techniques that are considered important enough to emphasize. Caution: procedures and techniques which, if not carefully followed, will result in damage to the equipment. Warning: p...

  • Page 3: Operation

    3 remote control the fireplace is supplied with a radio frequency remote control. This remote control has a range of approximately 50 feet (15.25 m), it does not have to be pointed at the fireplace and can pass through most obstacles (including walls). It is supplied with one of hundreds of independ...

  • Page 4

    4 www.Dimplex.Com maintenance warning: disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons. Partially reflective glass cleaning the partially reflective glass is cleaned in the factory during the assembly operation. During sh...

  • Page 5

    5 exploded parts diagram replacement parts list heater assembly (with cutout) 1. . . . . . . . . . . . . 2200490800rp front glass 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5902440100rp partially reflective glass 3. . . . . . . . . . . . . . . . . 5902420100rp flame panel 4. . . . . . ...

  • Page 6

    6 www.Dimplex.Com wiring diagram p1 p2.

  • Page 7

    7 switch replacement tools required: philips head screwdriver flat head screwdriver needle-nose pliers warning: if the fireplace was operating prior to ser- vicing, allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Warning: disconnect pow...

  • Page 8

    8 www.Dimplex.Com on either side of the firebox, remove the retaining 1. Screws and carefully remove the glass assembly from the rest of the assembly. (figure 3) carefully remove the glass media from the front tray. 2. Remove the fireplace assembly from the wall by care- 3. Fully lifting it upward, ...

  • Page 9

    9 (7) screws around the outside of the end panel. (figure 5) lay unit on its back and remove the remaining nine (9) 6. Screws from the end panel. Remove the end panel being careful not to add any 7. Strain to the wires connecting to the switches. Follow the wiring from the power cord up to the switc...

  • Page 10

    10 www.Dimplex.Com circuit board replacement remote control receiver or led driver board tools required: philips head screwdriver flat head screwdriver warning: if the fireplace was operating prior to ser- vicing, allow at least 10 minutes for light bulbs and heating elements to cool off to avoid ac...

  • Page 11

    11 place. (figure 8) inside the lower cavity, locate the flicker motor and 11. The flicker rod. The flicker rod can be removed by re- moving the brackets, the two that are attached together in the middle and the one at the end opposite the flicker motor. (figure 9 & 10) once the screws that attach t...

  • Page 12

    12 www.Dimplex.Com center of the back of the unit. (figure 7) lay unit on its back and remove the remaining nine (9) 7. Screws from the end panel. Remove the end panel being careful not to add any 8. Strain to the wires connecting to the switches. Gently guide the partially reflective glass out the ...

  • Page 13

    13 caution: ensure that the remote control wire antenna is placed so that it is not caught between any of the screws or sheets of metal. ! Note: be sure that the flanges on the end panel are positioned on the interior of the outside panel of the fire- place..

  • Page 14

    14 www.Dimplex.Com problem cause solution general circuit breaker trips or fuse blows when unit is turned on short in unit wiring. Trace wiring in unit. Improper circuit current rating additional appliances may exceed the current rating of the circuit breaker or fuse. Plug unit into another outlet o...

  • Page 15

    15 problem cause solution heater heater is not turning off improper operation refer to operation section defective heater on/off switch defective heater on/off switch defective remote control receiver replace remote control receiver. Initialize to re- mote control. Heater is not turning on improper ...