E.T. Systems Wingo 3524HS User Instructions - Ref
Ver: 2015.001
6
Basic operating features.
Manual override and end of travel referencing.
The ends of travel are consistently being monitored by the gate control software.
Whenever the gates are placed in manual override (Gates free to be manoeuvred by hand) the chances of engaging them again in the
exact same position is nearly impossible. For this reason the software will automatically go into an end of travel referencing operation.
NB! A momentary trigger on the BT, PED or BM inputs will pause the referencing routine. A repeat BT or PED trigger will allow it to
resume.
Action
Response
Engage the motors
again after moving the
gates.
No gate movement.
No Buzzer
tones.
Momentary BT trigger.
Gates begin closing if the last
operation before moving them
was an opening operation. If the
gates were closing before the
manual manoeuvre, then they
will begin opening.
No buzzer
tones.
Gates run up hard onto
the end stops as they
are out of reference
with the last position
memorized by the
control card.
Control card begins running the
standard safety overload routine
for that direction.
Buzzer beeps
confirmation of
which gate,
overloaded.
See trouble
shooting guide.
As soon as the first gate
passes the point at
which it was re-engaged
the control card will
know it is out of
reference to the gate
positions.
Buzzer begins beeping
intermittently and display shows
rEF.
Gate 1 continues to open slowly
searching for the open stopper.
ref
Gate 1 reaches the
open stopper and
surges up.
Buzzer continues beeping and
display continues showing rEF.
Gate 2 begins opening slowly.
ref
Gate 2 reaches the
open stopper and
surges up.
Buzzer continues beeping and
display continues showing rEF.
Referencing pauses with both
gates in the open position. The
system now waits for an
instruction to continue.
ref
Momentary BT or PED
trigger.
Buzzer continues beeping and
display continues showing rEF.
Gate 2 begins closing
ref
Gate 2 reaches closed
position.
Buzzer continues beeping and
display continues showing rEF.
Gate 1 begins closing
ref
Both gates reach the
closed position.
Buzzer silences and display
reverts to ready.
rdy
The system is now ready for normal use.