E2v AVIIVA EM2 User Manual

Other manuals for AVIIVA EM2: User Manual
Manual is about: Line Scan Camera

Summary of AVIIVA EM2

  • Page 1

    Aviiva em2/em4 line scan monochrome camera user manual.

  • Page 2: Aviiva® Em2/em4

    Aviiva® em2/em4 line scan camera 2 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 summary 1 camera overview.............................................................................5 1.1 features...............................................................................................

  • Page 3: Aviiva® Em2/em4

    Aviiva® em2/em4 line scan camera 3 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5.3.5 exposure and synchronization ............................................................................................................................... 27 5.3.6 gain and offset........................

  • Page 4: Aviiva® Em2/em4

    Aviiva® em2/em4 line scan camera 4 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 10 appendix e : command summary .................................................... 64 10.1 information...........................................................................................................

  • Page 5: Aviiva® Em2-Em4

    Aviiva® em2-em4 5 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 1 camera overview 1.1 features sensor : o 512 14x14µm or 1024 14x14µm or 2048 14x14µm or 4096 10x10µm pixels for machine vision versions (ba0) o 1024 14x28µm or 2048 10x20µm or 2048 14x28µm pixels for oct/spectrometer version...

  • Page 6: Aviiva® Em2-Em4

    Aviiva® em2-em4 6 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 1.2.2 oct/spectrometer versions (ba9) characteristics typical value unit sensor characteristics at maximum pixel rate resolution 1024 2048 2048 pixels pixel size (square) 14x28 14x28 10x20 µm max line rate – em4 (4 taps) 126 ...

  • Page 7: Aviiva® Em2-Em4

    Aviiva® em2-em4 7 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 1.3 description the aviiva em2/em4 is designed to set new standards for line scan cameras in term of speed and image quality. With resolutions of up to 4096 pixels, and the design of new ccd image sensors, it delivers state o...

  • Page 8: Aviiva® Em2-Em4

    Aviiva® em2-em4 8 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 2 camera performances 2.1 camera characterization 2.1.1 machine vision versions (ba0) unit min gain (-24db) av. Gain (-12db) max gain (0db) min typ. Max min typ. Max min typ. Max dark noise rms lsb - 1,6 2,6 6,4 27 - dynamic ...

  • Page 9: Aviiva® Em2-Em4

    Aviiva® em2-em4 9 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 2.2 image sensor the tap structure of the sensors is the following : on the ba9 versions, the pixel is rectangular in order to facilitate the positioning of the camera in the spectrometer : 20µm height for the 10µm pitch. 28µ...

  • Page 10: Aviiva® Em2-Em4

    Aviiva® em2-em4 10 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 2.3 response & qe curves 2.3.1 quantum efficiency 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 400 500 600 700 800 900 1000 1100 qe(%) 2.3.2 spectral response 0 20 40 60 80 100 120 140 160 180 200 400 500 600 700 800 900 1000 1100 ...

  • Page 11: Aviiva® Em2-Em4

    Aviiva® em2-em4 11 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 3 camera hardware interface 3.1 mechanical drawings em2 em4.

  • Page 12: Aviiva® Em2-Em4

    Aviiva® em2-em4 12 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 sensor alignment z = -10.3 ±150µm 4k 10µm : x = 7.52mm 2k 14µm : x = 13.66mm 1k 14µm : x = 20.83mm 512 14µm : x = 24.41mm ±100 µm y = 30mm ±100 µm planarity ±35 µm rotation (x,y plan) ±0,2° tilt (versus lens mounting plane) ...

  • Page 13: Aviiva® Em2-Em4

    Aviiva® em2-em4 13 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 3.2 input/output connectors and led double cameralink connectors for all possible modes : medium / dual base power connector : hirose 6pts 12v to 24v multi-colored led for status and diagnostic base cameralink connector powe...

  • Page 14: Aviiva® Em2-Em4

    Aviiva® em2-em4 14 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 status led behaviour after less than 2 seconds of power establishment, the led first lights up in orange. Then after a maximum of 30 seconds, the led must turn in a following colour : colour and state meaning green and conti...

  • Page 15: Aviiva® Em2-Em4

    Aviiva® em2-em4 15 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 3.3 cameralink output configuration aviiva em2: mode base connector cl1 2 channels 8bits 2 x 40mhz 2 channels 10bits 2 x 40mhz 2 channels 12bits 2 x 40mhz aviiva em4: modes connector cl1 connector cl2 base 80mhz : connector ...

  • Page 16: Aviiva® Em2-Em4

    Aviiva® em2-em4 16 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 connector cl2 assignment table: (em4 only) port/bit medium 8 bits medium 10bits medium 12bits port d0 d0 d0 d0 port d1 d1 d1 d1 port d2 d2 d2 d2 port d3 d3 d3 d3 port d4 d4 d4 d4 port d5 d5 d5 d5 port d6 d6 d6 d6 port d7 d7 ...

  • Page 17: Aviiva® Em2-Em4

    Aviiva® em2-em4 17 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 4 standard conformity the aviiva em2/em4 cameras have been tested using the following equipment: ¾ a shielded power supply cable ¾ a camera link data transfer cable ref. 14b26-szlb-500-olc (3m) e2v recommends using the same ...

  • Page 18: Aviiva® Em2-Em4

    Aviiva® em2-em4 18 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 4 getting started 4.1.1 out of the box the contains of the camera box is the following : there is no cdrom delivered with the camera : this user manual , but also the pleora puregev package, demogev and all documentation ass...

  • Page 19: Aviiva® Em2-Em4

    Aviiva® em2-em4 19 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 4.2 setting up in the system vocabulary : w = size of the sensor line (40,96mm for the 4k 10µm) fov = field of view (width of the web inspected by the sensor line) in mm. L = working distance (from the lens to the web) in mm...

  • Page 20: Aviiva® Em2-Em4

    Aviiva® em2-em4 20 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5 camera software interface 5.1 control and interface as all the e2v cameras, the aviiva ii is delivered with the friendly interface control software commcam.Ucl (as “ultimate camera link”) which is based on the genicam stan...

  • Page 21: Aviiva® Em2-Em4

    Aviiva® em2-em4 21 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5.2 serial protocol and command format the camera link interface provides two lvds signal pairs for communication between the camera and the frame grabber. This is an asynchronous serial communication based on rs-232 protoco...

  • Page 22: Aviiva® Em2-Em4

    Aviiva® em2-em4 22 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5.3 camera commands 5.3.1 information these values allow to indentify the camera. They can be accessed in commcam software in the “info” section all these values are fixed in factory and can’t be changed (shaded) except the ...

  • Page 23: Aviiva® Em2-Em4

    Aviiva® em2-em4 23 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 • device user id ( deviceuserid ) : camera user identifier id read function : “r cust”; returned by the camera : string of 128 bytes (including “/0”) write function : “w cust ” 5.3.2 dump and communication • dump : allows to...

  • Page 24: Aviiva® Em2-Em4

    Aviiva® em2-em4 24 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5.3.3 status, temperature & standby it can be accessed in commcam software in the “status” section : • temperature ( temperature ) : get internal temperature read function : “r temp”; return by the camera : temperature in q1...

  • Page 25: Aviiva® Em2-Em4

    Aviiva® em2-em4 25 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 • camera status : get the camera status register read function : “r stby”; returned by the camera : 32bits integer : bit 0 : ( statuswaitfortrigger ) : no trig received from more than 1sec bit 1 : ( statustriggertoofast ) : ...

  • Page 26: Aviiva® Em2-Em4

    Aviiva® em2-em4 26 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 • output mode ( outputmode ) : set the cameralink output mode (refer to chap 3.2.3 : cameralink output configuration). This command is available in the commcam “image format” section : read function : “r mode”; returned by t...

  • Page 27: Aviiva® Em2-Em4

    Aviiva® em2-em4 27 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 o medium 40mhz : 4 x channels diverging, interlaced by 2 5.3.5 exposure and synchronization • synchronisation mode ( synchromode ) : timed or triggered, it defines how the grabbing is synchronized. This command is available ...

  • Page 28: Aviiva® Em2-Em4

    Aviiva® em2-em4 28 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 timing specifications for all the modes detailed below, the readout is given as : nbpixels / (nbtaps * 40mhz) the necessary delay between the end of integration and the beginning of the readout (tdr) is calculated as 53 pixe...

  • Page 29: Aviiva® Em2-Em4

    Aviiva® em2-em4 29 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 ext trig with exposure time set in the camera this mode requires an external trigger ( via cc1) but the exposure time is the one defined in the camera. If the line period of the trig signal provided to the camera is lower th...

  • Page 30: Aviiva® Em2-Em4

    Aviiva® em2-em4 30 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 ext trig with exposure time controlled (itc) with one trig this mode requires an external trigger ( via cc1). Both exposure time and line period are defined by this trig signal : the exposure time during the low level of the...

  • Page 31: Aviiva® Em2-Em4

    Aviiva® em2-em4 31 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 • exposure time ( exposuretimeabs ): defines the exposure time when set in the camera. This command is available in the commcam “exposure” section : read function : “r tint”; returned by the camera : integer from 10 to 65535...

  • Page 32: Aviiva® Em2-Em4

    Aviiva® em2-em4 32 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5.3.6 gain and offset ultimate concept: a different way to set the gain in order to improve the tap balance the “u” concept has been developed to get a real improvement in term of tuning for the multi-tap sensors : as each s...

  • Page 33: Aviiva® Em2-Em4

    Aviiva® em2-em4 33 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 out ccd x preamp gain + x tap balance offset gain x amp gain + x ffc offset gain x ffc adjust + x lut or contrast exp. Offset gain action on whole line action per pixel action per sensor’s tap the global chain of gain is des...

  • Page 34: Aviiva® Em2-Em4

    Aviiva® em2-em4 34 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5.3.6.2 tap balance how to perform a tap balance ? Why and when performing a tap balance ? Each output of the sensor (tap) has its own analog chain and behavior. There could have some discrepancies between these outputs in e...

  • Page 35: Aviiva® Em2-Em4

    Aviiva® em2-em4 35 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 • automatic gain & offset tap balance : all the commands are available in the commcam “gain & offset / automatic balance” section : o offsets balance ( blacklevelautobalance ) : read function : “r balo”; returns the offset b...

  • Page 36: Aviiva® Em2-Em4

    Aviiva® em2-em4 36 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 o tap gain (blacklevelraw with blacklevelselector=tapx) : read function : “r fga”; is 1 to 4 (em4) or 1 to 2 (em2) returns the gain value for the tap. Ex : “ r fga1” returns gain value tap1. Write function : “w fga ” : 1 to ...

  • Page 37: Aviiva® Em2-Em4

    Aviiva® em2-em4 37 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5.3.7 flat field correction how is performed the flat field correction ? What is the flat field correction (ffc) ? The flat field correction is a digital correction on each pixel which allows : to correct the pixel prnu (pix...

  • Page 38: Aviiva® Em2-Em4

    Aviiva® em2-em4 38 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 how to perform the flat field correction ? Fpn/dsnu calibration cover the lens launch the fpn calibration : grab and calculation is performed in few seconds prnu calibration the user must propose a white/gray uniform target ...

  • Page 39: Aviiva® Em2-Em4

    Aviiva® em2-em4 39 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5.3.7.1 activation, filter and auto-adjust • ffc activation ( ffcenable ) : enable/disable the flat field correction. This command is available in the commcam “flat field correction” section : read function : “r ffcp” : retu...

  • Page 40: Aviiva® Em2-Em4

    Aviiva® em2-em4 40 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 • ffc adjust function : this feature is available in the commcam “flat field correction/ automatic calibration” section : o gains adjust ( ffcadjust ) : enable/disable the function read function : “r ffad”. Returns the statu...

  • Page 41: Aviiva® Em2-Em4

    Aviiva® em2-em4 41 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 o fpn coefficient reset ( fpnreset ) : reset the fpn (offsets) coefficient in memory. This command is available in the commcam “flat field correction / manual calibration ” section : write function : “w rsto 0” : reset (set ...

  • Page 42: Aviiva® Em2-Em4

    Aviiva® em2-em4 42 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5.3.7.3 manual flat field correction the ffc coefficients can also be processed outside of the camera or changed manually by accessing directly their values in the camera : this is the “manual” ffc. In commcam, the user can ...

  • Page 43: Aviiva® Em2-Em4

    Aviiva® em2-em4 43 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5.3.7.4 ffc user bank management the new-processed ffc values can be saved or restored in/from 4 x user banks. Both gains and offsets in the same time but also the ffc adjust user target and associated gain. These functions ...

  • Page 44: Aviiva® Em2-Em4

    Aviiva® em2-em4 44 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5.3.8 look up table the user can define an upload a lut in the camera that can be used at the end of the processing. The lut is defined as a correspondence between each of the 4096 gray levels (in 12 bits) with another outpu...

  • Page 45: Aviiva® Em2-Em4

    Aviiva® em2-em4 45 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 write function :” w lutc : write 128 lut coefficients starting from address form 0 to 4095-128. Is the concatenation in hexadecimal of individual lut values, without space between values. (one unsigned short per coefficient)...

  • Page 46: Aviiva® Em2-Em4

    Aviiva® em2-em4 46 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5.3.9 statistics and line profile this function allows the user to get some statistics on a pre-defined roi. On request, the camera acquires and then calculates some key values as the min, the max, the average or the standar...

  • Page 47: Aviiva® Em2-Em4

    Aviiva® em2-em4 47 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 pixel access line number ( pixelaccesslinenumer ) : set the number of lines to accumulate. Read function : “r pixl” : get the number of line returned by the camera : 1, 256, 521 or 1024 write function : “w pixl ” : set the n...

  • Page 48: Aviiva® Em2-Em4

    Aviiva® em2-em4 48 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 5.3.11 save & restore settings the settings (or main configuration) of the camera can be saved in 4 different user banks and one integrator bank. This setting includes also the ffc and lut enable this function is available i...

  • Page 49: Aviiva® Em2-Em4

    Aviiva® em2-em4 49 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 6 appendix a : test patterns 6.1 test pattern 1 : vertical wave the test pattern 1 is a vertical moving wave : each new line will increment of 1 gray level in regards with the previous one. In 12 bits the level reaches 4095 ...

  • Page 50: Aviiva® Em2-Em4

    Aviiva® em2-em4 50 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 6.2.3 2048 pixels pixel : 1 2 3 … 8 9 … 2040 2041 … 2047 2048 value : 0 0 0 … 0 1 … 254 255 … 255 255 6.2.4 4096 pixels pixel : 1 2 3 … 16 17 … 4080 4081 … 4095 4096 value : 0 0 0 … 0 1 … 254 255 … 255 255.

  • Page 51: Aviiva® Em2-Em4

    Aviiva® em2-em4 51 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 6.3 test pattern 2 : in 10 bits format 6.3.1 512 pixels em4 pixel : 1 2 3 … 256 257 258 … 509 510 511 512 value : 0 2 4 … 510 513 515 … 1017 1019 1021 1023 em2 pixel : 1 2 3 … 509 510 511 512 value : 0 2 4 … 1016 1018 1020 1...

  • Page 52: Aviiva® Em2-Em4

    Aviiva® em2-em4 52 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 6.3.3 2048 pixels pixel : 1 2 3 4 5 6 … 2044 2045 2046 2047 2048 value : 0 0 1 1 2 2 … 1021 1022 1022 1023 1023 6.3.4 4096 pixels pixel : 1 2 3 4 5 … 4092 4093 4094 4095 4096 value : 0 0 0 0 1 … 1022 1023 1023 1023 1023.

  • Page 53: Aviiva® Em2-Em4

    Aviiva® em2-em4 53 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 6.4 test pattern 2 : in 12 bits format 6.4.1 512 pixels em4 pixel : 1 2 3 … 255 256 257 … 510 511 512 value : 0 8 16 … 2040 2055 2063 … 4079 4087 4095 em2 pixel : 1 2 3 … 510 511 512 value : 0 8 16 … 4072 4080 4088 6.4.2 102...

  • Page 54: Aviiva® Em2-Em4

    Aviiva® em2-em4 54 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 6.4.3 2048 pixels em4 pixel : 1 2 3 … 1024 1025 1026 … 2045 2046 2047 2048 value : 0 2 4 … 2046 2049 2051 … 4089 4091 4093 4095 em2 pixel : 1 2 3 … 2045 2046 2047 2048 value : 0 2 4 … 4089 4091 4093 4094 6.4.4 4096 pixels pi...

  • Page 55: Aviiva® Em2-Em4

    Aviiva® em2-em4 55 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 7 appendix b : thermal management 7.1 heat sinks the most important source of heat in the camera is around the sensor. The em4 camera dissipates around 11w max with 4 taps at 40mhz (4k pixels version) the camera has been des...

  • Page 56: Aviiva® Em2-Em4

    Aviiva® em2-em4 56 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 7.2 temperature dropping some measurements have been done to establish the dropping temperature steps between different control points : ambient room temperature (burning room with controlled pulsed air) front face of the ca...

  • Page 57: Aviiva® Em2-Em4

    Aviiva® em2-em4 57 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 7.3 performance curves versus temperature these curves have been established with a 4k pixel camera (worst case). The “camera temperature” is given by the internal sensor of the camera. All the values in lsb are in 12 bits n...

  • Page 58: Aviiva® Em2-Em4

    Aviiva® em2-em4 58 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 the mean offset is the average value of the whole line of the sensor. The fpn peak to peak is the worst value for the whole line of the sensor. All the lsb values are in 12 bits average offset vs temperature : at min preamp ...

  • Page 59: Aviiva® Em2-Em4

    Aviiva® em2-em4 59 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 8 appendix c : optical mounts available 8.1 f-mount f mount : kit10 (part number at71kfpaviva-aba).

  • Page 60: Aviiva® Em2-Em4

    Aviiva® em2-em4 60 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 8.2 c-mount.

  • Page 61: Aviiva® Em2-Em4

    Aviiva® em2-em4 61 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 8.3 t2 & m42x1 mounts m42x0,75 (t2 mount) : kit30 (part number at71kfpaviva-aka) m42x1 mount : kit40 (part number at71kfpaviva-ada).

  • Page 62: Aviiva® Em2-Em4

    Aviiva® em2-em4 62 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 9 appendix d : troubleshooting 9.1 camera camera power up 20s no led red led color blinking green fixed green hardware failure or firmware loading defect. Contact hotline for rma if commcam connection possible : then the led...

  • Page 63: Aviiva® Em2-Em4

    Aviiva® em2-em4 63 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 9.2 commcam connection defect detail solutions commcam can’t find the camera : after launching commcam, the icon of the camera is not visible. • the camera is not powered up or the boot sequence is not finished. • the camera...

  • Page 64: Aviiva® Em2-Em4

    Aviiva® em2-em4 64 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 10 appendix e : command summary 10.1 information feature ( genicam ) cl command description (devicevendorname) r vdnm get camera vendor name as a string (32 bytes long including ‘\0’) (devicemodelname) r mdnm get camera mode...

  • Page 65: Aviiva® Em2-Em4

    Aviiva® em2-em4 65 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 10.3 standby, temperature and status feature ( genicam ) cl command description internal temp. Sensor (temperature) r temp read internal temperature (format signed q10.2 = signed 8 bits, plus 2 bits below comma. Value from -...

  • Page 66: Aviiva® Em2-Em4

    Aviiva® em2-em4 66 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 10.5 exposure and synchronization feature ( genicam ) cl command description w sync 0 set free run mode, with integration time and line period programmable w sync 1 set line period synchronisation with integration time progr...

  • Page 67: Aviiva® Em2-Em4

    Aviiva® em2-em4 67 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 feature ( genicam ) cl command description w offs set global offset from –4096 to +4095 in 12bits lsb (numeric offset) digital offset ( blacklevelraw with blacklevelselector = all ) r offs get global offset r fga1 get tap 1 ...

  • Page 68: Aviiva® Em2-Em4

    Aviiva® em2-em4 68 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 10.7 flat field correction feature ( genicam ) cl command description w ffco write128consecutive fpn user coefficients starting from the address. Is the concatenation of individual fpn values, without space between the value...

  • Page 69: Aviiva® Em2-Em4

    Aviiva® em2-em4 69 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 10.8 look up table feature ( genicam ) commands description r lute get lut status w lute 0 disable lut (“false”) (lutenable) w lute 1 enable lut (“true”) r lutc read 128 lut coefficients starting from address from 0 to 4095-...

  • Page 70: Aviiva® Em2-Em4

    Aviiva® em2-em4 70 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 10.10 privilege level feature ( genicam ) cl command description (privilegelevel) r lock get camera running privilege level 0 = privilege factory 1 = privilege advanced user 2 = privilege user w lock 2 lock camera privilege ...

  • Page 71: Aviiva® Em2-Em4

    Aviiva® em2-em4 71 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 11 appendix f : revision history manual revision comments / details firmware version 1 st commcam compliant version em4 4010 ba0 1.0.3c em4 2014 ba0 1.02c em4 2014 ba9 1.0.3c em4 2010 ba9 1.02c em2 4010 ba0 - em2 2014 ba0 - ...

  • Page 72: Aviiva® Em2-Em4

    Aviiva® em2-em4 72 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 em4 4010 ba0 1.0.4c em4 2014 ba0 1.0.3e em4 2014 ba9 1.0.5b em4 2010 ba9 1.0.5b em2 4010 ba0 1.0.2b em2 2014 ba0 1.0.2b em2 2014 ba9 1.0.3b em2 2010 ba9 1.0.3b em2 1014 ba0 1.0.0a em4 1014 ba0 1.0.0a em2 1014 ba9 1.0.0a em4 ...

  • Page 73: Aviiva® Em2-Em4

    Aviiva® em2-em4 73 1013d - aviiva em2/em4 02/11 e2v semiconductors sas 2011 how to reach us home page: www.E2v.Com sales office: europe regional sales office e2v ltd 106 waterhouse lane chelmsford essex cm1 2qu england tel: +44 (0)1245 493493 fax: +44 (0)1245 492492 mailto: enquiries@e2v.Com e2v sas...