Earlex Spraystation 5021 Operating Instructions Manual

Summary of Spraystation 5021

  • Page 1

    Operating instruction manual thank you for purchasing the professional earlex spraystation ® . This highly versatile hvlp (high volume of air, low-pressure) painting system can be used for a wide variety of applications. Before use – please read the manual and safety instructions. Please retain for ...

  • Page 2: Safety Instructions

    Safety instructions warning! Fire and explosion hazard • caution: to reduce the risk of electric shock or injury, do not expose to rain, store indoors. • the substances used with this spray gun (paint, thinners, etc) may contain hazardous, harmful, explosive or corrosive materials. Always comply wit...

  • Page 3

    • use only genuine earlex replacement parts. • only use the spray equipment as detailed in these instructions. • do not use the air hose (21) or power cord to pull the unit. • check the air hose (21), hose connectors and power cord before each use. Any worn or damaged parts should be replaced immedi...

  • Page 4: Parts List

    4 1 2 3 4 5 6 7 8 21 9 10 11 18 17 19 12 13 14 15 16 20 no. Description part no. 1. Air cap ring l1440 2. Air cap l1439 3. Air distributor plate l1438 4. Fluid tip l1444 5. Hang hook n/a 6. Main gun body l1475 7. Needle sleeve n/a 8. Adjuster adapter l1451 9. Fluid needle 1.5mm l1452 10. Spring l145...

  • Page 5: Selecting Spray Material

    Your earlex spraystation ® 5021 can be used with a wide variety of paints, stains and coatings such as latex, deck and fence stain, sealers, varnishes, wood preservatives, enamels, oil and water-based paints and automotive paints. However, some materials cannot be sprayed so please check the recomme...

  • Page 6: Spray Patterns

    6 the gun has 3 different spray patterns – horizontal, vertical and round (fig.1). The horizontal and vertical sprays are recommended for large surfaces. The round spray is used for small objects or for areas - such as corners – that are difficult to reach. To change the spray pattern simply rotate ...

  • Page 7: Periodic Maintenance

    7 the gland nut seal (18) prevents leakage of paint pass the fluid needle (9). This leakage reduces the performance of the spray gun and must, therefore, be kept to a minimum. After a period of use the gland nut seal (18) will wear. This is normal and can be compensated by gradual adjustment of the ...

  • Page 8: Problem

    8 problem cause action required the paint runs on the item being sprayed paint too diluted add undiluted material paint volume too high reduce the paint flow by turning adjuster cap (11) clockwise moving too slowly increase speed of application gun trigger held too long release trigger (19) earlier ...

  • Page 9: Mains Connection

    9 mains connection this unit is a class ii appliance which means it is double-insulated for your protection, no earthing wire is necessary. If the supply cord is damaged, it must be replaced by earlex ltd or our appointed agents to avoid a hazard. Your unit has been supplied with a mains cord with a...

  • Page 10

    10 ec declaration of conformity we declare that the unit hv5021 conforms to: lvd 2006/95/ec, en 60335-1, emf en50366, en 62233; emc 2004/108/ec, en55014-1, en55014-2, en 61000-3-2, en 61000-3-3. Tim hopper technical director please note: we have done all we can to ensure that if used correctly and a...

  • Page 11: Notes

    11 notes.

  • Page 12

    © 2012 earlex ltd l0936 12/12 earlex ltd , opus park, moorfield road, guildford, surrey, gu1 1sz, uk. Tel : +44 (0)1483 454666 fax : +44 (0)1483 454548 email : enquiries@earlex.Co.Uk website : www.Earlex.Com.