Earth Stove 2800HT Installation And Operation Manual

Other manuals for 2800HT: Installation And Operation Manual
Manual is about: Noncatalytic Wood Burning Fireplace Insert

Summary of 2800HT

  • Page 1

    Installation and operation manual model 2800ht retain these instructions for future reference epa certified wood burning fireplace insert this appliance must be installed by a qualified installer. Read entire manual thoroughly before installation. P/n 775004m, rev. J, 11/03.

  • Page 2

    Important warnings caution: please read this entire manual before you install and use your new room heater. For your safety, follow the installation, operation and maintenance instruc- tions exactly, without deviation. Failure to follow these instructions may result in property damage, bodily injury...

  • Page 3

    Page 3 table of contents important warnings .................................................2 testing / listing, epa, using this manual................ 3 planning your installation ..................................... 4-7 installation .......................................................... 8-12...

  • Page 4

    Planning your installation page 4 questions to ask local building official a correct installation is critical and imperative for reduc- ing fire hazards and perilous conditions that can arise when wood burning appliances are improperly installed. The installer must follow all of the manufacturer's i...

  • Page 5

    Planning your installation page 5 clearances warning: it is very important that you observe the minimum clearances. Do not store firewood within this clearance space. Failure to maintain clearances to all combustibles may result in a house fire. There are listed clearances for your fireplace insert,...

  • Page 6

    Planning your installation page 6 factory built fireplaces (not approved in canada) in the usa, this appliance is approved for installation into a listed factory built solid fuel burning fireplace (built to ul 127 or ulc s610 standards). The fireplace fire- box must accept the insert without modific...

  • Page 7

    Planning your installation page 7 masonry fireplaces this appliance is approved for installation into a ma- sonry fireplace built to ubc 37 or ulc s628 standards. Do not remove brick or mortar form the masonry fire- place to accommodate this appliance. If the fireplace has been modified to accommoda...

  • Page 8

    Installation page 8 fireplace installation • usa only - all masonry fireplace installations re- quire a minimum positive flue connection using a block-off plate or a positive seal past the bottom of the chimney flue tile liner. In canada, a full reline is required. • measure fireplace size to make c...

  • Page 9

    Installation page 9 power cord changeover danger: risk of electrical shock. Disconnect power before servicing appliance. Do not route power cord under or in front of appliance. To change the power cord from one side of insert to the other, perform the following steps: 1. Ensure power cord in not plu...

  • Page 10

    Installation page 10 10. Offsets can be handled using an offset adapter (it aligns starter pipe with flue. See offset adapter , page 26 for ordering information). Do not push insert in completely until surround assembly is installed. Care should be used to ensure that this adjustable connector is or...

  • Page 11

    Installation page 11 surround assembly important: do not face seal over chimney cooling air system on superior brand or any brand fireplace which is designed with the chimney cooling air system. 13. Pull the insert slightly forward to its desired position; attach the face shield using the sur- round...

  • Page 12

    Installation product features and controls page 12 positive flue connection for masonry fireplace (continued) a preferable installation is the positive flue connection (a positive seal between the flue extension and the chimney). This can be achieved by using a filler plate. A filler plate can be ma...

  • Page 13

    Care and operation page 13 gold door the doorframe is plated with 24-karat industrial grade gold and requires curing to harden the gold. Once it is cured it will never tarnish. Prior to burning this appliance the door- frame should be cleaned thoroughly with a good window cleaning solution and a sof...

  • Page 14

    Care and operation page 14 air draft controls this appliance has two combustion air controls located under the hearth extension. The control on the left is the start-up air control. The control in the center is the pri- mary air control. Start-up air control to provide sufficient combustion air to a...

  • Page 15

    Care and operation page 15 blower system the blower system consists of a on / off rocker switch, a variable speed blower speed control switch (rheostat) located on the right side panel, a thermally activated switch (fan disc) and 4 axial blowers. When starting a fire, leave the blower system off unt...

  • Page 16

    Fuel maintenance page 16 burn recommended fuel this appliance is approved for use with wood only. Use only natural dry untreated wood (see important warn- ings , page 2, #10). Do not burn particleboard scraps or pressed logs using bonding agents because they can produce conditions which will deterio...

  • Page 17

    Maintenance page 17 door gasket a spun fiberglass gasket (3/4" [19 mm] in diameter) pro- vides the seal around the fuel door. Should this become frayed or damaged it should be replaced. Spun fiberglass "rope" gasketing can be purchased from your dealer. It must be the same diameter as the original. ...

  • Page 18

    Maintenance page 18 cleaning – if the chimney is to be cleaned without re- moving the insert from the fireplace, the baffle plate (in the firebox) must first be removed. Chimney cleaning should only be done by a qualified chimney sweep. See following – cleaning / removing baffle plate . Cleaning / r...

  • Page 19

    Troubleshooting page 19 * smokes out fuel door when open 1. The primary air control is closed. 2. The chimney is too cool. Set the primary air control on high setting with start-up control open for a few minutes before opening the fuel door. 3. Excess creosote will not only restrict your draft but i...

  • Page 20

    Troubleshooting page 20 overfiring damage if the heater or chimney connector glows, you are overfir- ing. Other symptoms may include: cracking, warping or burning out of components, gold door may turn color, stove glass may develop a haze, which will not come off with cleaning. Overfiring of a stove...

  • Page 21

    Specifications - model 2800ht page 21 approx. Heat capacity up to ~1800 sq. Feet up to ~ 550 sq. Meters maximum log length 18" (457 mm) flue size 6" (152 mm) width w / standard surround 42" (107 cm) width at fireplace opening 24" (610 mm) width at rear of firebox 22 ½” (572 mm) depth into fireplace ...

  • Page 22

    Replacement parts list – model 2800ht page 22 part no. Description door parts g300 door assembly, gold (handle included) 86-128 gasket kit, 3/4" door rope (includes adhesive) 27m81 gasket kit, glass channel 27m67 clip set, glass g400-7 glass, large arched 11 1/8 x 17" (glass gasket not included) 103...

  • Page 23

    Replacement parts list – model 2800ht for the location of the nearest dealer for replacement parts, contact: lennox hearth products 1110 west taft avenue orange, ca 92865 page 23 part no. Description ms2805 marble set, green (also requires 1 each 1053 & 4 each 1051) 1053 cerawool pad for marble (req...

  • Page 24

    Component diagrams – model 2800ht page 24 firebrick (1 ¼” thick) air controls firebox parts door assembly handle assembly.

  • Page 25

    Safety/listing label page 25 catalog # model description (model) 14m78 oa2800-66 offset adapter, 6” to 6” diameter 14m74 zcfk-28 zero clearance fireplace kit 14m75 mfk-28 masonry fireplace kit 70k99 tspk-b touch-up spray paint kit, black 12 oz spray can offset adapter installations requiring offsets...

  • Page 26

    Safety/listing label page 26.

  • Page 27

    Epa label page 27.

  • Page 28

    Page 28 ownership records dealer’s name: dealer’s address: city: state: zip code: serial number: date of purchase: date installed: notes: service and maintenance log service service service date technician description.

  • Page 29: 1110 West Taft Avenue

    1110 west taft avenue orange, ca 92865.