The environmentally friendly ENERVEX EcoDamper
System is the first completely automated draft and
damper system for use with gas fireplaces. The
EcoDamper System quietly manages a perfect draft and
prevents conditioned air from escaping through the
chimney when the fireplace is not in use. It eliminates
the need for glass doors, opening up many new design
options while allowing for a larger view area of the fire
and a more natural look.
The system consists of the RS 9 Chimney Fan,
the Mechanical Fireplace Damper (MFD), the ADC100
Control and the PDS-1 Proven Draft Switch.
RS 9 Chimney Fan
Made of high quality, recycled cast aluminum, RS
Chimney Fans keep the perfect draft for a long time. The
fan features a quiet, enclosed pre-lubricated motor and
is recommended to be used with gas or oil fireplaces,
stoves, ovens, furnaces, water heaters, BBQs and pizza
ovens.
MFD Mechanical Fireplace Damper
The low profile Mechanical Fireplace Damper (MFD)
is an accessory to be used in conjunction with an ADC100
control and a chimney fan as part of the EcoDamper and
Intellidraft System. This damper prevents conditioned air
from escaping through the chimney when the fireplace is
not in use and eliminates the need for glass doors.
ADC100 Draft Control
The ADC100 Control, for gas appliances, has pre-
and postpurge features, an integrated damper relay and
includes a draft switch that shuts the appliance off when
there isn’t enough draft, protecting your family from
dangerous flue-gasses.
PDS-1 PROVEN DRAFT SWITCH
Use the PDS-1 Proven Draft Switch to provide
protection from insufficient draft. When there is an unsafe
draft, the switch shuts down the gas-fired appliance or
fireplace.
Installations must conform to requirements of the
authority having jurisdiction. Where required by the
authority having jurisdiction, the installation must also
conform to the Standard for Draft Equipment and The
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
All electrical wiring must be in accordance with
the requirements of authority having jurisdiction or, in
the absence of such requirements, with the National
Electrical Code, NFPA70.
This installation manual does not contain any system
design documentation. System design documentation is
available from any authorized ENERVEX representative.
Accessories, fans, and variable frequency drives are
not covered by this manual. Please refer to these
component’s individual manuals.
Earthcore Industries
08/2017
BVETTO B-Vent Gas Fireplace
- General Information & Components
Component
Part#
Description
EXH0021
RS 9 Chimney Fan
EXH2810-24
MFD Mechanical Fireplace Damper
EXH0060
ADC100 Draft Control
(includes PDS-1)
EXH1130
PDS-1 Proven Draft Switch
(included with ADC100)