Easy Radiant Works HI-30-40N2 Installation & Operating Instructions Manual

Manual is about: The Equator Series

Summary of HI-30-40N2

  • Page 1

    1 this heater may be installed up to a 35 degree angle. Installation above a 35 degree angle will voice warranty on the heater..

  • Page 2: “The Equator”

    2 12288 brawn rd, wainfleet, ontario, canada l0s 1v0 phone 905-899-3473 e-mail erw@vaxxine.Com fax 905-899-2262 installation/operating instructions for: “the equator” models hi-30-40n2 and hi-30-40p2 etl listed comforms to ansi std z83.19 certified to csa std 2.35 cga/csa std 2.17 5003356 liquid pro...

  • Page 3: Warning

    3 “the equator” is c.S.A. Design certified as a non-vented infrared heater for outdoor or indoor installation. All units are equipped with direct spark ignition and 100% safety shutoff for safety and economy. The aluminized steel enclosures and aluminium face grill provides resistance to wind and ra...

  • Page 4

    4 installations in canada must conform to the national standards of canada can/cga-b 149.1&2-m86, and all local codes. In the united states the installation of this appliance must conform with ansi standard z223.1 entitled “national fuel gas code” and any applicable local codes. Heaters installed in...

  • Page 5

    5 clearance guidlines “the equator” must be installed with adequate space around each unit. When placed near wood or other flammable materials, appropriate clearances from combustible materials must be maintained. Even if materials surrounding “the equator” are non-combustible, adequate space around...

  • Page 6

    6 ventilation 1. It is manditory that a minimum building ventilation rate of four (4) cfm per 1000 btuh of installed heater input be provided. This rate of ventilation may be obtained through either gravity or mechanical ventilation of the building. 2. In conjunction with building ventilation system...

  • Page 7

    7 electrical requirements 24 vac / 1ph / 60 hz. 3.0 a 120vac/1-ph/ 60 hz, 1a 6v or 9v battery pack a 120/ 24vac 20 va nec class 2 transformer is installed in “the equator”. “the equator” is supplied with a 3 wire plug in 120 volt connecting wire. If any factory wiring is to be replaced, it must be r...

  • Page 8

    8 “the equator” must be installed in a location so that it is readily accessible for servicing and have no restriction of airflow to the air inlet of the heater’s casing. Patio heating design considerations “the equator” placement is critical for effective and efficient patio heating. If heaters are...

  • Page 9

    9 typical patio layouts at a mounting height of 10 ft.(3 meters), “the equator” will heat an area of approximately 14 ft. X 14 ft. Or196 sq. Ft. (4.2 meters or 18.2 sq. Meters) conditions vary depending upon outdoor temperatures and wind conditions. Supporting structure supporting structure supporti...

  • Page 10

    10 lighting instructions: to start “the equator”: 1. Turn manual gas valve to “on” position. 2. Turn electrical supply “on” to shut down: 1. Turn manual gas valve to “off” position. 2. Turn electrical supply “off”. Caution: if burner fails to ignite, shut down electrical power and wait five (5) minu...

  • Page 11

    11 removal of the burner "the equator" easy radiant "works" 1 800 403 3279 "a" remove 6 screws from cover plate and grill "b" remove cover plate and grill remove pilot screen (2 srews) com com hi m high low o f f o n blue red white 36g54 typ 214 o f f o n red white 36g22 "c" disconnect wiring from v...

  • Page 12

    12 removal of the burner (con’t) "e" turn burner face down and remove (8) screws and remove back panel "f" remove the screws (4) and lift burner from enclosure.

  • Page 13

    13 trouble shooting if no spark from electrode or if gas valve does not work then a. Check your power supply. Should have 24 volts between power wires. Use a voltage meter between inlet 24 volts wire and ground terminal at electrode plate to measure 24 volts. B. Check continuity. Use ohmmeter. For e...

  • Page 14

    14 trouble shooting (continued) problem possible causes no spark  voltage under 24vac  improper spark gap (7/64” or .109)  loose ground wire  broken electrode  faulty electronic module burner won’t light  air in gas line  low gas pressure  bad gas valve  blockage in gas line  manual gas va...

  • Page 15: Warranty

    15 warranty this warranty is applicable to the original owner only in accordance with the warranty terms and conditions specified below easy radiant “works” (the manufacturer) will supply to the original owner. A replacement part or any component part which fails before three (3) years “no if’s and’...

  • Page 16

    16 hi-er-100

  • Page 17

    17.

  • Page 18

    18.

  • Page 19

    19.

  • Page 20

    20

  • Page 21

    21.

  • Page 22

    22.

  • Page 23

    23.

  • Page 24

    24.

  • Page 25

    25 programming instructions for “equator” r24v remote control for models hi-30-40n2br, hi-30-40p2br hi-30-40n2sr, hi-30-40n2sr erw-r (remote control receiver, factory installed in heater) erw-s (hand held remote control sender) for individual control of multiple heaters (i.E. Up to 4 heaters individ...

  • Page 26

    26 2 inputs “equator” with on / off & high / low hand held remote control. Your remote control (erw-s & erw-r) has been pre-programmed to work with your heater. Ensure that the “manual / remote” switch on the heater is in the “remote” position. To turn the heater on depress and hold for 5 seconds th...

  • Page 27

    27 multiple (2, 3 or 4) 2 inputs “equator” heaters with on / off & high / low hand held remote control. Your remote control (erw-s & erw-r) has been pre-programmed to work with your heaters. Ensure that the “manual / remote” switch on all the heaters is in the “remote” position. To turn on heater no...

  • Page 28: Appliance Inspection

    28 appliance inspection and maintenance failure to follow inspection guidelines can result in fire, damage to equipment, property, injury and death. It is ultimately the responsibility of the appliance owner to ensure the safe operation of the appliance. If you are unsure or unable to carry out the ...