Easydoor e Tel User Manual - 2. Operation Instructions
2. Operation Instructions
3. Setup Instructions
1) Door opening function:When visitor calls from outdoor station, the monitor rings,
pick up handset to talk with the visitor, then press the Unlock button to open the door.If
the system connect 2 locks,press Unlock 2nd button to open the second door.
2) Entrance monitoring: Pick up handset in standby mode,the LED will be shown a
scroll information "Intr Call",press Up button or Down button to stop the scroll,and
the LED show "ds-x"(x=1~4,refer to part 3-Numbers of door station),it means that the
monitor select "x" door station to mionitor.Press Up / Down button to increse/decrese
the value,then press Menu button to activate the monitoring.
3) Inner call: Use Up / Down button to select "-ALL" item on LED,then press Menu
button to activate the inner call,all monitors connected to the system will ring at the
same time.Pick up any monitor,the others will stop ringing immediately.(note that the
user code must be the same for all monitors to activate the inner call function)
4) Intercom call:Use Up / Down button to select "C-xx" (xx=00~31,refer to part3-
Numbers of indoor monitor)item on LED,then press Up / Down button to increse/
decrese the value,and press Menu button to confirm the intercom calling.(note that the
user code must be different for all monitors to activate the intercom call function)
Press Menu button and hold for 2s in standby mode,the LED will be shown a scroll
information "User Set-",press Up button or Down button to stop the scroll,and the LED
show the setting items.Press Menu button to select next setting items.
Setting
Item
L E D
state
Description
Default
Door station
call tone
1-xx
Set the ring tone calling from outdoor station.Total
12 pieces ring tones can be selected(xx=01~12),press
Up button or Down button to increse/decrese the
value,settings will be performed immediately.
02
Intercom
call tone
2-xx
Set the ring tone calling from intercom call
or inner call.Total 12 pieces ring tones can be
selected(xx=01~12),press Up / Down button to
increse/decrese the value,settings will be performed
immediately.
12