EasyRAID S8A2-U4R2 Hardware User Manual

Manual is about: ultra 320 SCSI to Serial ATA II Disk Array System

Summary of S8A2-U4R2

  • Page 1

    Easyraid s8a2 hardware user manual ultra 320 scsi to serial ata ii disk array systems version 1.1 www.Easyraid.Com.

  • Page 3: Easyraid S8A

    Easyraid s8a 2-u4r2 ultra 320 scsi to serial ata ii disk array system hardware user manual.

  • Page 5

    I table of contents preface................................................................................................................... I chapter 1 system requirements operating environment ....................................................................................1 vt100 terminal se...

  • Page 7

    I preface about this manual this manual is designed to make the disk array system as easy to use as possible. Information contained in this document has been checked for accuracy, but no guarantee is given that the con- tents are correct. Information and specifications are subject to change without ...

  • Page 8: Preface

    Ii easyraid s8a2 serial ata ii disk array systems preface – impo rtan t safety instru ctio ns, car e an d ha ndlin g important safety instructions, care and handling before starting, take a few minutes to read this manual. Read all of these instructions and save this manual for later reference. Prot...

  • Page 9: III

    Easyraid s8a2 serial ata ii disk array systems iii preface – impo rtan t safety instru ctio ns, car e an d ha ndlin g the appliance must be grounded. The disk array system is equipped with a 3-wire grounded type of power cord. This power cord will only fit into a grounded type of power outlet. If an...

  • Page 10: Preface

    Iv easyraid s8a2 serial ata ii disk array systems preface – impo rtan t safety instru ctio ns, car e an d ha ndlin g placement notes • the disk array system lcd panel can be damaged by exposure to direct sunlight. Limit exposure to subdued or indirect sunlight only. • the disk array system should be...

  • Page 11

    1 1 system requirements ensure that the following requirements are met before installing the disk array system. Operating environment • 15 cm (6-inches) of space around the disk array system for proper ventilation • ambient temperature of 5°c to 40°c (40°f to 104°f) • ambient non-condensing relative...

  • Page 12

    2 easyraid s8a2 serial ata ii disk array systems 1 syste m re quir em ents – host interface the disk array system has dual scsi interfaces. Refer to the following sections to understand host interface system requirements. Small computer systems interface the easyraid-s8a2 has dual ultra320 scsi inte...

  • Page 13

    3 2 basic configuration this chapter describes disk array system connections and disk installation. Unpacking contact your supplier if any of the following items are missing or damaged. Caution the disk array system is heavy. Be careful when lifting and moving it. Hardware user manual sa -43 40s ult...

  • Page 14

    4 easyraid s8a2 serial ata ii disk array systems 2 b asic c onfig ura tio n – c omp one nts components front panel no. Name description 1-8 disk trays 1 to 8 removable hot swap disk trays. 9 lcd panel displays warning, operating, and configuration information. 10 down function button moves down in t...

  • Page 15

    Easyraid s8a2 serial ata ii disk array systems 5 2 ba sic co nfigu ra tio n – co mpo nen ts disktray no. Name description 1 status led • green-disk online • red-no disk 2 access led this orangeled indicates that the disk is being accessed. 3 tray handle releases the disk tray. 2 1 front 3.

  • Page 16

    6 easyraid s8a2 serial ata ii disk array systems 2 ba sic co nfigu ra tio n – co mpo nen ts easyraid s8a2 rear view com ca t.5e lan host port 1 host port 2 fan 2/4 p/s 2 fan 1/3 1 8 9 10 3 11 12 13 2 7 4 5 6 no. Name description 1 cooling fan 1/3 system cooling fan.(fan1 is standard, fan3 is optiona...

  • Page 17

    Easyraid s8a2 serial ata ii disk array systems 7 2 bas ic c onfiguration – ins talling dis ks installing disks this section describes how to install disks in the disk array system. 1 unlock the disk tray with an included disk tray key 2 .Gently pull the disk tray handle to the opened position. 3 rem...

  • Page 18

    8 easyraid s8a2 serial ata ii disk array systems 2 bas ic c onfiguration – ins talling dis ks 4 insert the disk into the disk tray and fix into place with screws supplied with the disk. 5 slide the disk tray back into the empty slot. 6 slowly push the disk tray handle closed..

  • Page 19

    Easyraid s8a2 serial ata ii disk array systems 9 2 bas ic c onfiguration – ins talling dis ks 7 lock the disk tray with the key. 8 repeat steps 1 to 8 until all of the required disks have been installed..

  • Page 20

    10 easyraid s8a2 serial ata ii disk array systems 2 ba sic co nfigu ra tio n – m aking con nection s making connections after the required number of disks have been installed, external connections to the disk array system must be made. This section describes how to make all of the necessary connecti...

  • Page 21

    Easyraid s8a2 serial ata ii disk array systems 11 2 ba sic co nfigu ra tio n – m aking con nection s connecting a network connect the network cable to the rj-45 port at the rear of the unit. Ca t.5e com lan host port 1 host port 2 fan 2/4 fan 1/3 p/s 2.

  • Page 22

    12 easyraid s8a2 serial ata ii disk array systems 2 ba sic co nfigu ra tio n – m aking con nection s connecting and turning on the power 1 plug a power cable (a) to a power connector at the rear of the unit, then plug the second power supply cable into the second power connector ( b). 2 switch (c) o...

  • Page 23: 1 1 1 2 2 2 W R

    13 3 maintenance replacing a disk a disk failure is indicated when the power error led at the front of the drive tray turns red and the audible alert sounds. The lcd panel displays the failure with the symbol “r” or “w”. “r” indicates a disk failure or error, and “w” indicates that there are too man...

  • Page 24

    14 easyraid s8a2 serial ata ii disk array systems 3 ma inten ance – rep lacing a powe r supp ly replacing a power supply the disk array system is equipped with a power supply fail indicator led at the front of the unit that turns red when one of the power supplies fails. The message “power x failure...

  • Page 25

    Easyraid s8a2 serial ata ii disk array systems 15 3 ma inten ance – rep lacing a powe r supp ly 4 pull the power supply handle out. 5 remove the faulty power supply by pulling the power supply handle a and pressing the release catch b at the same time. 6 insert a new power supply. 7 push the power s...

  • Page 26

    16 easyraid s8a2 serial ata ii disk array systems 3 m ain te na nc e – up gr ad in g me m ory 8 tighten the power supply thumbscrew 9 reconnect the power cable. Upgrading memory the disk array system takes a single ddr-333 200-pin dimm with a maximum capacity of 1 gb. Follow these instructions to up...

  • Page 27

    Easyraid s8a2 serial ata ii disk array systems 17 3 m ain te na nc e – up gr ad in g me m ory 3 then remove the dimm. The dimm springs out of the socket. 4 gently push the new dimm into the stock at 45 degrees. 5 the push the corners of the dimm down. The dimm is secured by the dimm socket retaining...

  • Page 28

    18 easyraid s8a2 serial ata ii disk array systems 3 m ain te na nc e – up gr ad in g me m ory 6 place the top cover on the disk array system and replace the screws to fix the top cover on the disk system chassis. Ca t.5 e com lan host port 1 host port 2.

  • Page 29

    19 appendix hardware specifications item specification host interface scsi ultra320 disk interface sata ii, 3.0 gb/s dimensions 88 mm (h) x 480 mm (w) x 470 mm (d) raid functions • raid levels: jbod, 0, 1, 0+1, 3, 5, 6, 30, 50, tp, nraid • hot spare support • disk hot swapping with automatic online ...

  • Page 30: Appendix

    20 easyraid s8a2 serial ata ii disk array systems appendix – ha rd wa re sp ecificatio ns controller backplane item specification cpu intel i80331 64-bit risc microprocessor disk interface sata ii (3.0 gb/s) disk channels 8 channels memory type ddr-333 200-pin dimm memory sockets 1 memory size up to...