Eaton 1000L User Manual

Manual is about: On-line ups

Summary of 1000L

  • Page 2

    Contents : 1. Int ro d uc tio n ................................................................................................1 2. Im po rt an t s af e ty in st ru ct io n s...........................................................2 3. S ys tem de sc ript io n .......................................

  • Page 3

    ---1--- the on-line-series is an uninterruptible power supply incorporating double-converter technology. It provides perfect protection specifically for novell, windows nt and unix servers. The double-converter principle eliminates all mains power disturbances. A rectifier converts the alter- nating...

  • Page 4: Save These Instructions

    ---2--- transport ● please transport the ups system only in the original packaging (to protect against shock and impact). Set-up ● condensation may occur if the ups system is moved directly from a cold to a warm environment. The ups system must be absolutely dry before being installed. Please allow ...

  • Page 5

    ---3--- ● do not connect appliances or items of equipment which would overload the ups system (e.G. Laser printers) to the ups outlet socket. ● place cables in such a way that no one can step on or trip over them. Operation ● do not disconnect the mains cable on the ups system or the building wiring...

  • Page 6

    ---4--- 3.1 front panel switch function on - switch 1. Turn on ups system: by pressing the on-switch “ i ” the ups system is turned on. 2. Deactivate acoustic alarm : by pressing this switch an acoustic alarm can be deactivated. Standby - switch the ups system switches to standby mode when the stand...

  • Page 7

    ---5--- 3. System description display function line-led 1. The green line led lights up if mains voltage is applied to the ups input. 2. Line-led blinks when the phase and neutral conductor have been reversed at the input of the ups system. 3. If line-led and battery-led light up, the mains power su...

  • Page 8

    ---6--- the system may be installed and wired only by qualified electricians in accordance with applicable safety regulations! When installing the electrical wiring, please note the nominal amperage of your incoming feeder. 1) inspect the packaging carton and its contents for damage. Please inform t...

  • Page 9

    ---7--- 1500lxl (4 pcs of 12v batteries),96vdc for 3000lxl (8 pcs of 12v batteries), connection of batteries more than or less than required will cause abnormality 8-2 both two ends of the external battery cord are plugs for connecting the ups and the battery pack. The battery connection procedure i...

  • Page 10

    ---8--- if the ups system does not operate correctly, please attempt to solve the problem using the table below. Please have the following information at hand before calling the after-sales service department: 1. Model number, serial number 2. Date on which the problem occurred 3. Detailed descripti...

  • Page 11

    ---9--- 6.1 operation the ups system contains no user-serviceable parts. If the battery service life (3 - 5 years at 25 °c ambient temperature) has been exceeded, the batteries must be exchanged. In this case please contact your dealer. 6.2 storage if the batteries are to be stored in temperate clim...

  • Page 12: Dimensions

    ---10--- 7.1 electrical specifications 7.2 typical stored energy time (battery mode) typical values at 25°c in minutes: 7.3 dimensions and weights model 1000l(xl) 1500 l(xl) 3000 l(xl) input voltage 60vac~138 vac frequency 46hz ~ 54hz / 56hz ~ 64hz amperage(maximu m) 10a 15a 24a output power rating ...

  • Page 13

    ---11--- 7.5 communication port the type of signals, serial command(rs232), is provided by the ups to communicate with a host computer. The rs232 communication port transmits both utility power and ups status to the host computer, providing the host computer with proprietary command sequence to moni...

  • Page 14

    ---12--- figure 3: db9 interface of as400 vommunication protocol 7.6 operating environment temperature: 0 °c to 40 °c, installation height relative humidity: 0 to 95%, non-condensing 7.5.2 as400 interface except for the communication protocol as mentioned above, this series ups has as400 card (an op...

  • Page 15

    ---13--- figure 4: back view of dx1000l figure 5: back view of dx1000lxl 8. Appendix communication port breaker input socket intelligent slot cooling fan output socket rj45 communication port breaker input socket intelligent slot cooling fan output socket rj4 5 external battery socket.

  • Page 16

    ---14--- figure 6: back view of dx1500l communication port input socket cooling fan rj45 intelligent slot intelligent slot output socket output socket breaker communication port input socket cooling fan rj45 intelligent slot intelligent slot output socket output socket breaker external battery socke...

  • Page 17

    ---15--- breaker output socket fuse cooling fan rj45 intelligent slot communication p ort figure 8: back view of dx3000l 8. Appendix breaker cooling fan communication p ort input te rminal b lock intelligent slot output socket fuse rj45 external battery socket figure 9 : back view of dx3000lxl.

  • Page 18

    ---16--- 614-03752-00