  • Page 1

    English 9px 700 rt 9px 1000 rt 9px 1000grt 9px 1500 rt 9px 1500grt 9px 2000 rt 9px 2200 grt 9px 3000 rt 9px 3000 grt 9px 3000 glrt 9px ebm 36v rt 9px ebm 48v rt 9px ebm 72v rt installation and user manual copyright © 2016 eaton all rights reserved. 9px 1-3 kva us_en.

  • Page 2: Safety Instructions

    Page 2 9px 1-3 kva us_en save these instructions. This manual contains important instructions that should be followed during installation and maintenance of the ups and batteries. The 9px models that are covered in this manual are intended for installation in an environment within 0 to 40°c, free of...

  • Page 3: Safety Instructions

    Page 3 9px 1-3 kva us_en english safety instructions safety of persons • the system has its own power source (the battery). Consequently, the power outlets may be ener- gized even if the systems is disconnected from the ac power source. Dangerous voltage levels are present within the system. It shou...

  • Page 4: Safety Instructions

    Page 4 9px 1-3 kva us_en safety instructions special precautions • the unit is heavy: wear safety shoes and use vacuum lifter preferentially for handling operations. • all handling operations will require at least two people (unpacking, lifting, installation in rack system). • before and after the i...

  • Page 5: Contents

    Page 5 9px 1-3 kva us_en english contents 1. Introduction ......................................................................................... 1.1 environmental protection ...............................................................................................6 2. Presentation .............

  • Page 6: 1. Introduction

    Page 6 9px 1-3 kva us_en 1. Introduction thank you for selecting an eaton product to protect your electrical equipment. The 9px range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your ups (uninterruptib...

  • Page 7: 1. Introduction

    Page 7 9px 1-3 kva us_en english 1. Introduction the eaton ® 9px uninterruptible power system (ups) protects your sensitive electronic equipment from the most common power problems, including power failures, power sags, power surges, brownouts, line noise, high voltage spikes, frequency variations, ...

  • Page 8: 2. Presentation

    Page 8 9px 1-3 kva us_en 2. Presentation 2.1 standard installations tower installation d w h rack installation d h w description weights (lb/ kg ) dimensions (inch/ mm ) d x w x h 9px700rt 36.4 / 16.5 17.7 x 17.3 x 3.4 / 450 x 440 x 86.5 9px1000rt 36.4 / 16.5 17.7 x 17.3 x 3.4 / 450 x 440 x 86.5 9px...

  • Page 9: 2. Presentation

    Page 9 9px 1-3 kva us_en english 2. Presentation 2.2 rear panels 9px 700rt / 9px 1000rt / 9px 1500rt 1 2 3 4 5 6 9 8 11 10 7 9px 2000rt 1 8 2 4 3 5 6 9 10 11 7 9px 1000grt, 9px 1500grt, 9px 2200grt & 9px 3000grt 1 8 2 4 3 5 9 10 11 6 7 9px 3000rt (*) 1 8 2 4 3 5 6 9 10 11 7 9px 3000glrt 1 8 2 4 3 5 ...

  • Page 10: 2. Presentation

    Page 10 9px 1-3 kva us_en 2. Presentation 9px ebm 36v/48v 13 13 12 12 12 connectors for battery modules (to the ups or to the other battery modules) 13 connectors for automatic recognition of battery modules 9px ebm 72v 13 13 12 12 2.3 accessories part number description 9pxebm36rt2u 9pxebm48rt2u 9p...

  • Page 11: 2. Presentation

    Page 11 9px 1-3 kva us_en english 2. Presentation 2.4 control panel the ups has a five-button graphical lcd. It provides useful information about the ups itself, load status, events, measurements and settings. Online mode indicator (green) fault indicator (red) online mode 100% 19min 1ebm 100% 2.7kw...

  • Page 12: 2. Presentation

    Page 12 9px 1-3 kva us_en 2. Presentation 2.5 lcd description after 5 minutes of inactivity, the lcd displays the screen saver. The lcd backlight automatically dims after 10 minutes of inactivity. Press any button to restore the screen. Operation status load/equipment status online mode 100% 19min 1...

  • Page 13: 2. Presentation

    Page 13 9px 1-3 kva us_en english 2.6 display functions press the enter ( ) button to activate the menu options. Use the two middle buttons ( and ) to scroll through the menu structure. Press the enter ( ) button to select an option. Press the button to cancel or return to the previous menu. Main me...

  • Page 14: 2. Presentation

    Page 14 9px 1-3 kva us_en 2. Presentation submenu available settings default settings in/out settings output voltage [100v] [110v] [120v] [125v] [200v] [208v] [220v] [230v] [240v] [120v] [208v] output frequency mode: [normal] [converter] [marine] frequency can be changed in frequency [converter] mod...

  • Page 15: 2. Presentation

    Page 15 9px 1-3 kva us_en english submenu available settings default settings battery settings automatic battery test in abm cycling mode : [no test] [every abm cycle] in constant charge mode: [no test] [every day] [every week] [every month] [every abm cycle] [every week] low battery warning [capaci...

  • Page 16: 2. Presentation

    Page 16 9px 1-3 kva us_en 2. Presentation submenu available settings default settings com settings output signals [relay] [db9-1] [db9-7] [db9-8] sets events or fault that will actuate output signal parameters through external contact connector or rs232 port [relay]: [on bat] [low bat] [bat fault] [...

  • Page 17: 3. Installation

    Page 17 9px 1-3 kva us_en english 3.1 inspecting the equipment if any equipment has been damaged during shipment, keep the shipping cartons and packing materials for the carrier or place of purchase and file a claim for shipping damage. If you discover damage after acceptance, file a claim for conce...

  • Page 18: 3. Installation

    Page 18 9px 1-3 kva us_en 3.2 checking the accessory kit 9px 1000grt / 9px 1500grt / 9px 2200grt / 9px 3000grt 3. Installation 14 19 25 26 24 27 20 21 23 22 16 28 15 17 18 14 9px ups 15 connection cable to ac-power source 16 2 connection cables for the protected equipment 17 rs232 communication cabl...

  • Page 19: 3. Installation

    Page 19 9px 1-3 kva us_en english 3.2 checking the accessory kit 9px 3000glrt 3. Installation 14 19 25 26 24 20 21 23 22 15 17 18 14 9px ups 15 connection cable to ac-power source 17 rs232 communication cable 18 usb communication cable 19 cable locking system 20 manual cd-rom 21 software leaflet 22 ...

  • Page 20: 3. Installation

    Page 20 9px 1-3 kva us_en 3. Installation • if you ordered an optional extended battery module (ebm), verify that the following additional items are included with the ebm: 3 4 2 1 1 battery power cable with attached battery detection cable 2 stabilizer bracket (4 screws included) 3 rack kit for 19-i...

  • Page 21: 3. Installation

    Page 21 9px 1-3 kva us_en english 3. Installation 3.3 connecting the internal battery do not connect the ups to utility until installation is completed. 3 5 2 1 4 to connect the ups: 1. Remove the center cover of the front panel. 2. Push left cover toward to right direction. 3. Open the left side of...

  • Page 22: 3. Installation

    Page 22 9px 1-3 kva us_en 3. Installation 3.4 connecting the ebm(s) a small amount of arcing may occur when connecting an ebm to the ups. This is normal and will not harm personnel. Insert the ebm cable into the ups battery connector quickly and 1. Plug the ebm power cable(s) into the battery connec...

  • Page 23: 3. Installation

    Page 23 9px 1-3 kva us_en english 3. Installation 3.6 tower installation • adjustment of the orientation of the lcd panel and of the logo. • adjustment of the angle of vision of the lcd panel. If you ordered other ups accessories, refer to specific user manuals to check the tower installation with t...

  • Page 24: 3. Installation

    Page 24 9px 1-3 kva us_en 3.7 rack installation • rack mounting of ups, ebm, and accessory modules. Follow steps 1 to 4 for module mounting on the rails. 3 3 4 4 2 1 1 the rails and necessary hardware are supplied by eaton. 3. Installation.

  • Page 25: 3. Installation

    Page 25 9px 1-3 kva us_en english 3. Installation 3.8 ups connection without hotswap mbp module check that the indications on the name plate located on the back of the ups correspond to the ac-power source and the true electrical consumption of the total load. 15 1 16 19 7 6 5 1. 9px 2000rt / 3000rt...

  • Page 26: 3. Installation

    Page 26 9px 1-3 kva us_en 3. Installation 3.9 connection with a hotswap mbp module (optional accessory) the hotswap mbp module makes it possible to service or even replace the ups without affecting the connected loads. 9px 2000rt mbp-120 load 15 28 1 8 2 4 3 5 6 9 10 11 7 29 33 34 35 36 9px 3000rt m...

  • Page 27: 3. Installation

    Page 27 9px 1-3 kva us_en english 3. Installation 9px 2200grt & 9px 3000grt 1 mbp load 29 30 33 31 34 35 36 15 28 32 6 7 5 1. Connect the input 36 on the hotswap mbp module to the ac-power source. 2. Connect the ups input cable 1 to the “ups input socket” 35 on the hotswap mbp module. 3. Connect the...

  • Page 28: 4. Communication

    Page 28 9px 1-3 kva us_en 4. Communication 4.1 communication ports connection of rs232 or usb communication port the rs232 and usb communication ports cannot operate simultaneously. 9 10 17 18 1. Connect the rs232 17 or usb 18 communication cable to the serial or usb port on the com- puter equipment...

  • Page 29: 4. Communication

    Page 29 9px 1-3 kva us_en english 4.2 ups remote control functions programmable signal inputs the 9px incorporates 3 programmable signal inputs: one remote power off (rpo) input terminal, one remote on/off (roo) input terminal, one rs-232 input (pin-4). Signal inputs can be configured (see settings ...

  • Page 30: 4. Communication

    Page 30 9px 1-3 kva us_en • remote on/off (roo) remote on/off allows remote action of button to switch on/off the ups. When contact changes from open to closed, the ups is switched-on (or stays on). When contact changes from closed to open, the ups is switched-off (or stays off). On/off control via ...

  • Page 31: 4. Communication

    Page 31 9px 1-3 kva us_en english 4. Communication connectivity cards connectivity cards allow the ups to communicate in a variety of networking environments and with dif- ferent types of devices. The 9px models have one available communication bay for the following connectivity cards: • network-ms ...

  • Page 32: 5. Operation

    Page 32 9px 1-3 kva us_en 5. Operation 5.1 start-up and normal operation to start the ups: 1. Verify that the internal batteries are connected. See "connecting the internal battery" on page 21. 2. If optional ebms are installed, verify that the ebm are connected to the ups. See "connecting the ebm(s...

  • Page 33: 5. Operation

    Page 33 9px 1-3 kva us_en english 5. Operation low-battery warning • the indicator illuminates solid. • the audio alarm beeps every three seconds. The remaining battery power is low. Shut down all applications on the connected equipment because automatic ups shutdown is imminent. End of battery back...

  • Page 34: 5. Operation

    Page 34 9px 1-3 kva us_en 5. Operation qualify bypass the default setting (“in spec”) allows a transfer to bypass only when bypass is within the following specifi - cations: • bypass voltage is between the “bypass voltage low limit” and “bypass voltage high limit” settings • bypass frequency is with...

  • Page 35: 6. Ups Maintenance

    Page 35 9px 1-3 kva us_en english 6. Ups maintenance 6.1 equipment care for the best preventive maintenance, keep the area around the equipment clean and dust free. If the atmosphere is very dusty, clean the outside of the system with a vacuum cleaner. For full battery life, keep the equipment at an...

  • Page 36: 6. Ups Maintenance

    Page 36 9px 1-3 kva us_en 6. Ups maintenance 6.4 replacing batteries do not disconnect the batteries while the ups is in battery mode. Batteries can be replaced easily without turning off the ups or disconnecting the load. If you prefer to remove input power to change the batteries, see "ups shutdow...

  • Page 37: 6. Ups Maintenance

    Page 37 9px 1-3 kva us_en english 6. Ups maintenance to replace the battery pack: 1. Remove the center cover of the front panel. 2. Push left cover toward to right direction. 3. Open the battery door. 4. Disconnect the battery connectors. A ribbon cable connects the lcd control panel to the ups. Do ...

  • Page 38: 6. Ups Maintenance

    Page 38 9px 1-3 kva us_en 6. Ups maintenance 6.5 replacing the ups equipped with a hotswap mbp the hotswap mbp module makes it possible to service or even replace the ups without affecting the connected loads. Maintenance 1. Set switch 33 to bypass position. The red led on the hotswap mbp module goe...

  • Page 39: 7. Troubleshooting

    Page 39 9px 1-3 kva us_en english 7. Troubleshooting the eaton 9px are designed for durable, automatic operation and also alert you whenever potential ope- rating problems may occur. Usually the alarms shown by the control panel do not mean that the output power is affected. Instead, they are preven...

  • Page 40: 7. Troubleshooting

    Page 40 9px 1-3 kva us_en 7. Troubleshooting ups overtemperature the ups internal temperature is too high or a fan has failed. At the warning level, the ups generates the alarm but remains in the current operating state. If the temperature rises another 10°c, the ups transfers to bypass mode or shut...

  • Page 41: 8. Specifications

    Page 41 9px 1-3 kva us_en english 8. Specifications 8.1 model specifications input filter ac/dc boost dc/ac inverter outpout filter bypass dc/dc battery charger table 1. Power module model list model power ratings 9px700rt 700va / 630w 9px1000rt 1000va / 900w 9px1000grt 1000va / 900w 9px1500rt 1500v...

  • Page 42: 8. Specifications

    Page 42 9px 1-3 kva us_en 8. Specifications table 4. Electrical input nominal frequency 50/60hz auto-sensing frequency range 40-70hz before transfer to battery bypass voltage range -20% / +15% of nominal value (default) noise filtering input emc filter model default input (voltage/max current) input...

  • Page 43: 8. Specifications

    Page 43 9px 1-3 kva us_en english 8. Specifications table 6. Electrical output all models normal mode efficiency mode battery mode voltage regulation ±1% ±2% efficiency 89.9% for 700 lv models 90.3% for 1k lv models 90.2% for 1k g models 90.0% for 1.5k lv models 91% for 1.5k g models 91.4% for 2k lv...

  • Page 44: 8. Specifications

    Page 44 9px 1-3 kva us_en table 8. Environmental and safety certifications iec/en 62040-1 iec/en 62040-2 : cat. C1 iec/en 62040-3 ul1778 5th edition csa 22.2 emc (emissions)* cispr22 class b fcc part 15 class b / ices-003 emc (immunity) iec 61000-4-2, (esd): 8 kv contact discharge / 15 kv air discha...

  • Page 45: 9. Glossary

    Page 45 9px 1-3 kva us_en english 9. Glossary bypass ac source source supplying the bypass line. The equipment can be transferred to the by- pass line if an overload occurs on the ups output, for maintenance or in the event of a malfunction. Frequency converter operating mode used to convert the ac-...

  • Page 46

    Page 46 9px 1-3 kva us_en.