  • Page 1

    Power protection handbook for ibm system i and system p applications powerware 9910 ups international july 2008.

  • Page 2: Table of Contents

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 1 table of contents resources and sales tools on the web: powerware.Com/ibm ......................................................... 2 9 power problems and their ups solutions ...................................................................................

  • Page 3

    Powerware power protection handbook for ibm 9910 international system i and system p applications 2 resources and sales tools on the web: powerware.Com/ibm the following information is available to you on the web or from your eaton ® representative. Please note that the web site is updated more freq...

  • Page 4

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 3 9 power problems and their ups solutions.

  • Page 5

    Powerware power protection handbook for ibm 9910 international system i and system p applications 4 ups topologies: online, line-interactive, and standby online ups technology online upss are designed to provide complete power protection. They isolate equipment from all types of power problems by co...

  • Page 6

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 5 frequently asked questions 1. What happens if the ups is overloaded? For example, if the protected equipment and/or load draws more current than the ups can provide. The ups transfers the load to bypass (for a few minutes) until the overload condition is ...

  • Page 7

    Powerware power protection handbook for ibm 9910 international system i and system p applications 6 preventing ups problems the following observations can help you avoid potential problems with the sale and installation of a ups. Observation #1 alone will protect you from a large percentage of probl...

  • Page 8

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 7 rohs compliant and pre-rohs part number cross reference chart the restriction of hazardous substances directive (rohs) became european law in february 2003. This directive restricts the use of six hazardous materials in the manufacture of various types of...

  • Page 9

    Powerware power protection handbook for ibm 9910 international system i and system p applications 8 glossary of power terms ampere (a or amp) – the unit of measure for the “rate of flow” of electricity, analogous to “gallons per minute.” va x 0.7 (power factor) = watts alternating current (ac) – an ...

  • Page 10: Glossary Of Power Terms

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 9 glossary of power terms (continued) maintenance bypass – an external wiring path to which the load can be transferred in order to upgrade or perform service on the ups without powering down the load. Make-before-break – operational sequence of a switch or...

  • Page 11

    Powerware power protection handbook for ibm 9910 international system i and system p applications 10 commonly-used acronyms abm advanced battery management ac alternating current bbm break-before-make (bypass switch) bdm bypass distribution module btu british thermal unit csa canadian standards asso...

  • Page 12

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 11 recommended powerware 9910 ups by application server (power draw) p16 p14 e30 e33 e64 e65 e83 power systems power 520 (750w) 8204-e4a (aix, linux) 9407-m15 (ibm i, (i5/os)) 9408-m25 (ibm i, (i5/os)) z z z z z z z z power 550 (1,100w) 8204-e8a (aix, linux...

  • Page 13

    Powerware power protection handbook for ibm 9910 international system i and system p applications 12 how much battery runtime do you need? To meet customer needs of continued operation during power outages, powerware 9910 ups solutions offer options that can extend battery runtimes beyond 60 minutes...

  • Page 14

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 13 attributes at a glance attribute p14 p16 e30 e33 e64 e65 e83 ibm part number 39j4810 39j4812 42r8069 42r8065 42r8073 42r8077 44v3923 vac input/output 230 230 208-240 208-240 208-240 208-240 220-240 maximum output (watts) 950 1050 2100 2700 4200 4500 8000...

  • Page 15: Powerware 9910-P14

    Powerware power protection handbook for ibm 9910 international system i and system p applications 14 powerware 9910-p14 950 watt/1400 va, 230 vac ups features and benefits • low cost power protection for entry- to mid-level desk side servers • extends battery service life and provides advanced warni...

  • Page 16

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 15 p14 technical specifications* electrical input nominal voltage 230 vac (user selectable to 220 vac) online voltage range ±20% for nominal voltage at full load nominal input frequency 45–65 hz, 50/60 hz; auto-sensing input protection reset-able circuit br...

  • Page 17

    Powerware power protection handbook for ibm 9910 international system i and system p applications 16 what’s included with the p14 ups • 950w/1400 va, 230v ups • serial cable, db-9 to db-9 (6 ft/1.8m) • as/400 interface cable (6 ft/1.8m) • usb cable, db-9 to usb (6 ft/1.8m) • powerware 5115 ups user’...

  • Page 18

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 17 powerware 9910-p16 1050 watt/1500 va, 230 vac ups features and benefits • isolates connected equipment from all incoming power problems to provide the highest degree of protection with rugged, online design • significantly increases battery service life ...

  • Page 19

    Powerware power protection handbook for ibm 9910 international system i and system p applications 18 p16 technical specifications* electrical input nominal voltage 230 vac input voltage ranges 150–288v (without using batteries) input power factor >0.95 typical frequency 50/60 hz, auto-sensing freque...

  • Page 20

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 19 what’s included with the p16 ups • 1050w/1500 va, 230v ups • powerware 9125 ups user’s guide • powerware 9125 installation guide for ibm applications • x-slot relay interface adapter card user’s guide • x-slot ria quick start guide • as/400 interface cab...

  • Page 21: Powerware 9910-E30

    Powerware power protection handbook for ibm 9910 international system i and system p applications 20 powerware 9910-e30 2100 watt/3000 va, 208-240 vac ups features and benefits • isolates connected equipment from all incoming power problems to provide the highest degree of protection with rugged, on...

  • Page 22

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 21 what’s included with the e30 ups • 2100w /3000 va, 208-240v ups • e30 accessory kit (ibm part number 42r8070) - ups safety manual - powerware 9125 (2500–3000 va) ups user’s guide - powerware 9125 (9910 e30) installation guide for ibm applications - power...

  • Page 23

    Powerware power protection handbook for ibm 9910 international system i and system p applications 22 e30 technical specifications* electrical input nominal voltage 208, 220, 230 and 240 vac input voltage ranges 160–288v (without using batteries) input power factor >0.95 typical frequency 50/60 hz, a...

  • Page 24: Powerware 9910-E33

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 23 powerware 9910-e33 2700 watt/3000 va, 208-240 vac ups features and benefits • 0.9 power factor delivers more real output power in order to power more servers than another ups of equivalent va rating • conservers valuable space with 2u rack height • hot-s...

  • Page 25

    Powerware power protection handbook for ibm 9910 international system i and system p applications 24 e33 technical specifications* electrical input nominal voltage 208, 220, 230, and 240 vac input voltage ranges 154–288v frequency 50/60 hz, auto-sensing frequency range 46–65 hz electrical output on ...

  • Page 26

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 25 what’s included with the e33 ups • 2700w/3000 va, 208–240v ups • e33 accessory kit (ibm part number 42r8066) • powerware 5125 (2500–3000 va) ups user’s guide • powerware 5125 (9910 e33) installation guide for ibm applications • (4) iec-320-c13 to iec-320...

  • Page 27

    Powerware power protection handbook for ibm 9910 international system i and system p applications 26 powerware 9910-e64 4200 watt/6000 va, 208-240 vac ups features and benefits • isolates connected equipment from all incoming power problems to provide the highest degree of protection with rugged, on...

  • Page 28

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 27 what’s included with the e64 ups • 4200w/6000 va, 208–240v ups • (2) ups internal battery trays (ibm part number 42r4316) • e64 accessory kit (ibm part number 42r8074) - ups safety manual - ups lower front panel (bezel) black - powerware 9125 (5000/6000 ...

  • Page 29

    Powerware power protection handbook for ibm 9910 international system i and system p applications 28 e64 technical specifications* electrical input nominal voltage 208, 220, 230, and 240 vac input voltage ranges 160–288v (without using batteries) frequency 50/60 hz, auto-sensing input power factor >...

  • Page 30

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 29 e64 applications matrix various options are available depending on application. For system i or system p applications, consult chart below to select appropriate feature codes to order with the e64 ups. Description ibm feature code ibm part number power (...

  • Page 31

    Powerware power protection handbook for ibm 9910 international system i and system p applications 30 powerware 9910-e65 4500 watt/5000 va, 208-240 vac ups features and benefits • high power, low profile design ideal for dense i5, p5, system i, system p and power configurations • supports multiple pd...

  • Page 32

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 31 e65 technical specifications* electrical input nominal voltage 200/208, 220, 230, and 240 vac input voltage ranges 160–288v frequency 50/60 hz, auto-sensing frequency range 46–54 hz for 50 hz; 56–64 hz for 60 hz electrical output on utility voltage regul...

  • Page 33

    Powerware power protection handbook for ibm 9910 international system i and system p applications 32 what’s included with the e65 ups • 4500w/5000 va, 208–240v ups • (2) battery trays (ibm part number 39j4828) • accessory kit (ibm part number 42r8078) consisting of - ups front panel (bezel) black - ...

  • Page 34

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 33 powerware 9910-e83 8000 watt/10000 va, 220-240 vac ups features and benefits • high power, low profile design ideal for dense i5, p5 or blades • system i, system p and power configurations • supports multiple pdus (1–5 pdus in a non-redundant power confi...

  • Page 35

    Powerware power protection handbook for ibm 9910 international system i and system p applications 34 e83 rear panel what’s included with the e83 ups • 8000w/10000 va, 220v nominal, optional 208, 230–240v ups • (4) battery trays (ibm part number 44v3920) • (internal) accessory kit (no ibm pn) - mount...

  • Page 36

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 35 e83 technical specifications* electrical input nominal voltage 220 default, optional; 200, 208, 230, and 240 vac input voltage ranges 220/230/240; 174-288v or 200/208; 160–253v, frequency 50/60 hz, auto-sensing frequency range 45-65hz default frequency 6...

  • Page 37

    Powerware power protection handbook for ibm 9910 international system i and system p applications 36 environmental and safety operating temperature 0 to 40°c (32 to 104°f) storage temperature -20 to 50°c (-4 to 122°f) relative humidity 0% to 95% noncondensing heat dissipation 2066 btu/hr (605.5w) ma...

  • Page 38

    Www.Powerware.Com/ibm +44 (0) 845 177 3410 37 powerware software and connectivity power management software unifies and centralizes ups management bundled with every powerware 9910 ups, powerware lansafe power management software gives you control and visibility over all your ups systems, using an i...

  • Page 39

    United states 8609 six forks road raleigh, nc 27615 u.S.A. Toll free: 1.800.925.4426 or 919.872.3020 www.Powerware.Com/ibm eaton, powerware, abm, lansafe, connectups, and x-slot are trade names, trademarks and/or service marks of eaton corporation or its sub- sidiaries and affiliates. All other trad...